Development of a Monte Carlo simulation for APO-based PET detectors using a continuous scintillating crystal

被引:0
|
作者
Clowes, Peter [1 ]
McCallum, Stephen [1 ]
Welch, Andy [1 ]
机构
[1] Univ Aberdeen, Dept Biomed Phys & Bioengn, John Mallard Scottish PET Ctr, Aberdeen AB25 2ZD, Scotland
关键词
avalanche photodiode (APD)-array; continuous lutetium yttrium ortho-silicate (LYSO); Monte Carlo; positioning algorithm;
D O I
10.1109/TNS.2006.878005
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We are currently developing a multilayer avalanche photodiode (APD)-based detector for use in positron emission tomography (PET), which utilizes thin continuous crystals. In this paper, we developed a Monte Carlo-based simulation to aid in the design of such detectors. We measured the performance of a detector comprising a single thin continuous crystal (3.1 mm x 9.5 mm, x 9.5 mm) of lutetium yttrium ortho-silicate (LYSO) and an APD array (4 x 4) elements; each element 1.6 mm(2) and on a 2.3 mm pitch. We showed that a spatial resolution of better than 2.12 mm is achievable throughout the crystal provided that we adopt a Statistics Based Positioning (SBP) Algorithm. We then used Monte Carlo simulation to model the behavior of the detector. The accuracy of the Monte Carlo simulation was verified by comparing measured and simulated parent datasets (PDS) for the SBP algorithm. These datasets consisted of data for point sources at 49 positions uniformly distributed over the detector area. We also calculated the noise in the detector circuit and verified this value by measurement. The noise value was included in the simulation. We show that the performance of the simulation closely matches the measured performance. The simulations were extended to investigate the effect of different noise levels on positioning accuracy. This paper showed that if modest improvements could be made in the circuit noise then positioning accuracy would be greatly improved. In summary, we have developed a model that can be used to simulate the performance of a variety of APD-based continuous crystal PET detectors.
引用
收藏
页码:2563 / 2569
页数:7
相关论文
共 50 条
  • [11] Development of a Monte Carlo simulation to study linear radiation position sensitive detectors
    de Mesquita, Carlos Henrique
    Hamada, Margarida Mizue
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 871 - 875
  • [12] Monte Carlo modeling of scintillator crystal performance for stratified PET detectors with DETECT2000
    Cayouette, F
    Moisan, C
    Zhang, N
    Thompson, CJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 624 - 628
  • [13] The Effect of Crystal Size on Position Detection Accuracy in PET Block Detectors: A Monte Carlo Study
    Lashkari, S.
    Sarkar, S.
    Ay, M.
    Rahmim, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S409 - S409
  • [14] Material optimization in dual particle detectors by comparing advanced scintillating materials using two Monte Carlo codes
    Al Hamrashdi, H.
    Cheneler, D.
    Monk, S. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 869 : 163 - 171
  • [15] Monte Carlo simulation of the system performance of a long axial field-of-view PET based on monolithic LYSO detectors
    Abi-Akl, Maya
    Dadgar, Meysam
    Toufique, Yassine
    Bouhali, Othmane
    Vandenberghe, Stefaan
    EJNMMI PHYSICS, 2023, 10 (01)
  • [16] Monte Carlo simulation of the system performance of a long axial field-of-view PET based on monolithic LYSO detectors
    Maya Abi-Akl
    Meysam Dadgar
    Yassine Toufique
    Othmane Bouhali
    Stefaan Vandenberghe
    EJNMMI Physics, 10
  • [17] MONTE-CARLO SIMULATION OF CONTINUOUS-SPACE CRYSTAL-GROWTH
    DODSON, BW
    TAYLOR, PA
    PHYSICAL REVIEW B, 1986, 34 (04): : 2112 - 2115
  • [18] MONTE-CARLO SIMULATION OF THE CRYSTAL SIZE DISTRIBUTION IN A CONTINUOUS SUCROSE CRYSTALLIZER
    SENGUPTA, B
    DUTTA, TK
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1991, 46 (02): : B35 - B41
  • [19] Evaluation of the continuous detector concept for PET systems dedicated to small animals by using the Monte Carlo simulation method
    Erturk, S. S.
    Guvenis, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S344 - S344
  • [20] Validation of a Monte Carlo simulation of the Inveon PET scanner using GATE
    Lu, Lijun
    Zhang, Houjin
    Bian, Zhaoying
    Ma, Jianhua
    Feng, Qiangjin
    Chen, Wufan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 828 : 170 - 175