Development of a Monte Carlo simulation for APO-based PET detectors using a continuous scintillating crystal

被引:0
|
作者
Clowes, Peter [1 ]
McCallum, Stephen [1 ]
Welch, Andy [1 ]
机构
[1] Univ Aberdeen, Dept Biomed Phys & Bioengn, John Mallard Scottish PET Ctr, Aberdeen AB25 2ZD, Scotland
关键词
avalanche photodiode (APD)-array; continuous lutetium yttrium ortho-silicate (LYSO); Monte Carlo; positioning algorithm;
D O I
10.1109/TNS.2006.878005
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We are currently developing a multilayer avalanche photodiode (APD)-based detector for use in positron emission tomography (PET), which utilizes thin continuous crystals. In this paper, we developed a Monte Carlo-based simulation to aid in the design of such detectors. We measured the performance of a detector comprising a single thin continuous crystal (3.1 mm x 9.5 mm, x 9.5 mm) of lutetium yttrium ortho-silicate (LYSO) and an APD array (4 x 4) elements; each element 1.6 mm(2) and on a 2.3 mm pitch. We showed that a spatial resolution of better than 2.12 mm is achievable throughout the crystal provided that we adopt a Statistics Based Positioning (SBP) Algorithm. We then used Monte Carlo simulation to model the behavior of the detector. The accuracy of the Monte Carlo simulation was verified by comparing measured and simulated parent datasets (PDS) for the SBP algorithm. These datasets consisted of data for point sources at 49 positions uniformly distributed over the detector area. We also calculated the noise in the detector circuit and verified this value by measurement. The noise value was included in the simulation. We show that the performance of the simulation closely matches the measured performance. The simulations were extended to investigate the effect of different noise levels on positioning accuracy. This paper showed that if modest improvements could be made in the circuit noise then positioning accuracy would be greatly improved. In summary, we have developed a model that can be used to simulate the performance of a variety of APD-based continuous crystal PET detectors.
引用
收藏
页码:2563 / 2569
页数:7
相关论文
共 50 条
  • [1] Development of a Monte Carlo simulation for APD based PET detectors using continuous scintillation crystal
    Clowes, P
    McCallum, S
    Welch, A
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2591 - 2595
  • [2] Noise Optimization and Monte Carlo Simulation of a PET Detector Based on Continuous LSO Crystal and Large-Area APDs
    Krishnamoorthy, S.
    Stoll, S.
    Purschke, M.
    Pratte, J. -F.
    Woody, C. L.
    Schlyer, D. J.
    O'Connor, P.
    Vaska, P.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3068 - 3071
  • [3] Programmable integrated front-end for SiPM/PMT PET detectors with continuous scintillating crystal
    Herrero-Bosch, V.
    Monzo, J. M.
    Ros, A.
    Aliaga, R. J.
    Gonzalez, A.
    Montoliu, C.
    Colom-Palero, R. J.
    Benlloch, J. M.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [4] On modelling continuous agglomerative crystal precipitation via Monte Carlo simulation
    Falope, GO
    Jones, AG
    Zauner, R
    CHEMICAL ENGINEERING SCIENCE, 2001, 56 (07) : 2567 - 2574
  • [5] Monte Carlo simulation of the crystal size distribution in a continuous sucrose crystallizer
    Sen Gupta, Bhaskar
    Kumar Dutta, Tapas
    Chemical engineering journal, 1991, 46 (02):
  • [6] Monte Carlo simulation of transient crystal size distribution in a continuous crystallizer using the ASL model
    Lim, KC
    Hashim, MA
    Sen Gupta, B
    CRYSTAL RESEARCH AND TECHNOLOGY, 1998, 33 (02) : 249 - 255
  • [7] Monte Carlo simulation of transient crystal size distribution in a continuous crystallizer using the ASL model
    Univ of Malaya, Kuala Lumpur, Malaysia
    Cryst Res Technol, 2 (249-255):
  • [8] Monte Carlo simulation in PET and SPECT instrumentation using GATE
    Assié, K
    Breton, V
    Buvat, I
    Comtat, C
    Jan, S
    Krieguer, M
    Lazaro, D
    Morel, C
    Rey, M
    Santin, G
    Simon, L
    Staelens, S
    Strul, D
    Vieira, JM
    Van de Walle, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2): : 180 - 189
  • [9] Effect of Scintillator Crystal Geometry and Surface Finishing on Depth of Interaction Resolution in PET Detectors - Monte Carlo Simulation and Experimental Results using Silicon Photomultipliers
    Cuddy, Sarah
    Reznik, Alla
    Rowlands, John A.
    Taghibakhsh, Farhad
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [10] Monte Carlo based performance assessment of different animal PET architectures using pixellated CZT detectors
    Visvikis, D.
    Lefevre, T.
    Lamare, F.
    Kontaxakis, G.
    Santos, A.
    Darambara, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 225 - 229