Ultrafiltration of biologically treated domestic wastewater: How membrane properties influence performance
被引:14
|
作者:
Filloux, E.
论文数: 0引用数: 0
h-index: 0
机构:
Veolia Res & Innovat Chemin Digue, Maisons Laffitte, France
Univ Poitiers, UMR IC2MP 7285, Inst Chim Milieux & Mat Poitiers, F-86022 Poitiers, France
Univ Queensland, Adv Water Management Ctr, St Lucia, Qld 4072, AustraliaVeolia Res & Innovat Chemin Digue, Maisons Laffitte, France
Filloux, E.
[1
,2
,3
]
Teychene, B.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Poitiers, UMR IC2MP 7285, Inst Chim Milieux & Mat Poitiers, F-86022 Poitiers, FranceVeolia Res & Innovat Chemin Digue, Maisons Laffitte, France
Teychene, B.
[2
]
Tazi-Pain, A.
论文数: 0引用数: 0
h-index: 0
机构:
Veolia Res & Innovat Chemin Digue, Maisons Laffitte, FranceVeolia Res & Innovat Chemin Digue, Maisons Laffitte, France
Tazi-Pain, A.
[1
]
Croue, J. P.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Poitiers, UMR IC2MP 7285, Inst Chim Milieux & Mat Poitiers, F-86022 Poitiers, France
King Abdullah Univ Sci & Technol, Water Desalinat & Reuse Ctr, Thuwal, Saudi ArabiaVeolia Res & Innovat Chemin Digue, Maisons Laffitte, France
Croue, J. P.
[2
,4
]
机构:
[1] Veolia Res & Innovat Chemin Digue, Maisons Laffitte, France
[2] Univ Poitiers, UMR IC2MP 7285, Inst Chim Milieux & Mat Poitiers, F-86022 Poitiers, France
[3] Univ Queensland, Adv Water Management Ctr, St Lucia, Qld 4072, Australia
[4] King Abdullah Univ Sci & Technol, Water Desalinat & Reuse Ctr, Thuwal, Saudi Arabia
In this study, the impact of membrane properties on membrane fouling and permeate water quality was investigated. Short- and long-term laboratory scale experiments using four commercially available hollow fiber UF membranes were performed to study the impact of membrane properties on reversible and irreversible fouling. No significant differences in terms of permeate quality (i.e. biopolymer rejection) were observed over the four tested membranes. It was found that membrane characteristics including pore size, pore distribution and especially materials had a strong impact on the filtration performances in terms of both reversible and irreversible fouling. The short-term filtration tests showed that due to its specific hydrodynamic condition only the inside-out mode UF membrane was subjected to irreversible fouling. These data demonstrate the importance of membrane selection with appropriate operating conditions for optimum performances. The added value of membrane characterization to lab-scale filtration tests for membrane performance was discussed. (C) 2014 Elsevier B.V. All rights reserved.