Prediction of two-phase pressure gradients of refrigerants in horizontal tubes

被引:34
|
作者
Didi, MBO [1 ]
Kattan, N [1 ]
Thome, JR [1 ]
机构
[1] Swiss Fed Inst Technol, EPFL, Dept Mech Engn, LTCM,Lab Heat & Mass Transfer, CH-1015 Lausanne, Switzerland
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2002年 / 25卷 / 07期
关键词
refrigerant; two-phase flow; pressure drop; horizontal tube; calculation; R134a; R123; R402A; R404A; R502;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Two-phase pressure drop data were obtained for evaporation in two horizontal test sections of 10.92 and 12.00 mm diameter for five refrigerants (R-134a, R-123, R-402A, R-404A and R-502) over mass velocities from 100 to 500 kg/m(2) s and vapor qualities from 0.04 to 1.0. These data have then been compared against seven two-phase frictional pressure drop prediction methods. Overall, the method by Muller-Steinhagen and Heck (Muller-Steinhagen H, Heck K. A simple friction pressure drop correlation for two-phase flow in pipes. Chem. Eng. Process 1986;20:297-308) and that by Gronnerud (Gronnerud R. Investigation of liquid hold-up, flow-resistance and heat transfer in circulation type evaporators, part IV: two-phase flow resistance in boiling refrigerants. Annexe 1972-1, Bull. de l'Inst. du Froid, 1979) were found to provide the most accurate predictions while the widely quoted method of Friedel (Friedel L. Improved friction drop correlations for horizontal and vertical two-phase pipe flow. European Two-phase Flow Group Meeting, paper E2; June 1979; Ispra, Italy) gave the third best results. The data were also classified by two-phase flow pattern using the Kattan-Thome-Favrat (Kattan N, Thome JR, Favrat D. Flow boiling in horizontal tubes. Part 1: development of a diabatic two-phase flow pattern map. J. Heat Transfer 1998; 120:140-7; Kattan N, Thome JR, Favrat D. Flow boiling in horizontal tubes. Part 2; new heat transfer data for five refrigerants. J Heat Transfer 1998; 120:148-55; Kattan N, Thome JR, Favrat D. Flow boiling in horizontal tubes. Part 3: development of a new heat transfer model based on flow patterns. J. Heat Transfer 1998;120:156-65) flow pattern map. The best available method for annular flow was that of Muller-Steinhagen and Heck. For intermittent flow and stratified-wavy flow, the best method in both cases was that of Gronnerud. It was observed that the peak in the two-phase frictional pressure gradient at high vapor qualities coincided with the onset of dryout in the annular flow regime. (C) 2002 Elsevier Science Ltd and IIR. All rights reserved.
引用
收藏
页码:935 / 947
页数:13
相关论文
共 50 条
  • [31] Characterization and prediction of two-phase flow regimes in miniature tubes
    Rahim, Emil
    Revellin, Remi
    Thome, John
    Bar-Cohen, Avram
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2011, 37 (01) : 12 - 23
  • [32] Prediction of two-phase flow patterns for evaporation of refrigerant R-407C inside horizontal tubes
    Zürcher, O
    Thome, JR
    Favrat, D
    CONVECTIVE FLOW AND POOL BOILING, 1999, : 287 - 292
  • [33] Two-phase frictional pressure drop correlations for small tubes
    Chen, IY
    Yang, KS
    Wang, CC
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM-2001, 2001, 552 : 247 - 254
  • [34] ASPECTS OF TWO-PHASE FRICTIONAL PRESSURE DROP IN TUBES.
    Kubie, J.
    Oates, H.S.
    1978, 56 (03): : 205 - 209
  • [35] Effect of diameter on two-phase pressure drop in narrow tubes
    Venkatesan, M.
    Das, Sarit K.
    Balakrishnan, A. R.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2011, 35 (03) : 531 - 541
  • [36] Two-phase flow patterns and pressure drop inside horizontal tubes containing twisted-tape inserts
    Kanizawa, Fabio Toshio
    Ribatski, Gherhardt
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2012, 47 : 50 - 65
  • [37] Flow boiling in horizontal flattened tubes: Part I - Two-phase frictional pressure drop results and model
    Quiben, Jesus Moreno
    Cheng, Lixin
    Lima, Ricardo J. da Silva
    Thome, John R.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (15-16) : 3634 - 3644
  • [38] EXPERIMENTAL RESULTS FOR HFO-1234yf VISUALIZATION AND TWO-PHASE PRESSURE GRADIENT IN HORIZONTAL STRAIGHT TUBES
    Padilla, M.
    Revellin, R.
    Haberschill, P.
    Bonjour, J.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 827 - 834
  • [39] EXPERIMENTAL STUDY ON TWO-PHASE PRESSURE DROP OF AIR-WATER IN SMALL DIAMETER TUBES AT HORIZONTAL ORIENTATION
    Autee, Arun
    Rao, S. Srinivasa
    Puli, Ravikumar
    Shrivastava, Ramakant
    THERMAL SCIENCE, 2014, 18 (02): : 521 - 532
  • [40] Development of a correlation for pressure drop of two-phase flow inside horizontal small diameter smooth and microfin tubes
    Bashar, M. Khairul
    Nakamura, Keisuke
    Kariya, Keishi
    Miyara, Akio
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 119 : 80 - 91