Chemically-modified carbon paste electrode for the voltammetric determination of bismuth

被引:0
|
作者
Ferri, T [1 ]
Paci, S [1 ]
Morabito, R [1 ]
机构
[1] ENEA CR CASACCIA,DEPT ENVIRONM,I-00060 ROME,ITALY
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper deals with the preparation and analytical characterisation of a Bismuthiol II-carboxylate (5-mercapto-3-(p-carboxyphenyl)-1,3,4-thiadiazoline-2-thione) Modified Carbon Paste Electrode (BMCPE) to be used in the voltammetric analysis of bismuth. The influence of different experimental parameters (composition procedure, scan rate, etc.) on the electrode behaviour is evaluated. Bismuth can be determined by a stripping procedure in which it is non-electrochemically preconcentrated at the electrode (at open circuit) thank to the formation of a complex with the modifier present in the electrode surface. It is then reduced (stripped) by linearly scanning the potential (200 mV s(-1)) from -100 to -800 mV. Under suitable experimental conditions, bismuth can be determined from 1.5x10(-8) mol l(-1) (5 min of preconcentration time) to 6x10(-6) mol l(-1) (1 min of preconcentration) with a precision never worse than +/-7%. The electrode has also been tested on actual samples.
引用
收藏
页码:245 / 256
页数:12
相关论文
共 50 条
  • [41] Voltammetric copper(II) determination with a montmorillonite-modified carbon paste electrode
    Kula, P
    Navratilova, Z
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 354 (5-6): : 692 - 695
  • [42] Manganese dioxide-modified carbon paste electrode for voltammetric determination of riboflavin
    Eda Mehmeti
    Dalibor M. Stanković
    Sudkate Chaiyo
    Ľubomir Švorc
    Kurt Kalcher
    Microchimica Acta, 2016, 183 : 1619 - 1624
  • [43] Voltammetric Determination of Boron using Cobalt Phthalocyanine Modified Carbon Paste Electrode
    Tunay, Zeki
    Sahin, Ibrahim
    Nakiboglu, Nuri
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (12): : 6628 - 6638
  • [44] Voltammetric determination of imazaquin using polyaniline modified carbon paste electrode (CPE)
    Consolin, N
    Venâncio, EC
    de Medeiros, ES
    Tanimoto, ST
    Machado, SAS
    Mattoso, LHC
    SENSOR LETTERS, 2006, 4 (01) : 11 - 16
  • [45] Voltammetric copper(II) determination with a montmorillonite-modified carbon paste electrode
    Institute of Geonics, Academy of, Sciences of Czech Republic,, Studertska 1768, 708 00 Ostrava, Czech Republic
    Fresenius J Anal Chem, 5-6 (692-695):
  • [46] VOLTAMMETRIC DETERMINATION OF PENTACHLOROPHENOL WITH A SILICA GEL-MODIFIED CARBON PASTE ELECTRODE
    BARRIO, MAR
    CARRAZON, JMP
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 344 (1-2): : 34 - 38
  • [47] Voltammetric Determination of Carbidopa Using a modified Multiwall Carbon Nanotube Paste Electrode
    Mohadesi, Alireza
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (03): : 2430 - 2439
  • [48] Voltammetric determination of trace amounts of permanganate at a zeolite modified carbon paste electrode
    Nosuhi, Motahare
    Nezamzadeh-Ejhieh, Alireza
    NEW JOURNAL OF CHEMISTRY, 2017, 41 (24) : 15508 - 15516
  • [49] A zeolite modified carbon paste electrode as useful sensor for voltammetric determination of acetaminophen
    Ahmadpour-Mobarakeh, Leila
    Nezamzadeh-Ejhieh, Alireza
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 49 : 493 - 499
  • [50] Sensitive voltammetric determination of rutin at an ionic liquid modified carbon paste electrode
    Zhanga, Ya
    Zhenga, Jianbin
    TALANTA, 2008, 77 (01) : 325 - 330