Distributed Polarization Characteristic Testing for Optical Closed Loop of Sagnac Interferometer

被引:4
|
作者
Zhang, Haoliang [1 ,2 ]
Yuan, Yonggui [1 ,2 ]
Zhu, Yunlong [1 ,2 ]
Dang, Fanyang [1 ,2 ]
Yu, Zhangjun [3 ,4 ,5 ]
Yang, Jun [3 ,4 ,5 ]
Wang, Yuncai [3 ,4 ,5 ]
Qin, Yuwen [3 ,4 ,5 ]
机构
[1] Harbin Engn Univ, Key Lab Fiber Integrated Opt, Minist Educ China, Harbin 150001, Peoples R China
[2] Harbin Engn Univ, Coll Phys & Optoelect Engn, Harbin 150001, Peoples R China
[3] Univ Technol, Adv Inst Photon Technol, Guangzhou 510006, Peoples R China
[4] Univ Technol, Sch Informat Engn Guangdong, Guangzhou 510006, Peoples R China
[5] Guangdong Prov Key Lab Photon Informat Technol, Guangzhou 510006, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical interferometry; Optical polarization; Optical fibers; Optical fiber sensors; Optical crosstalk; Sagnac interferometers; Adaptive optics; Distributed polarization characteristic; optical closed loop; Sagnac interferometer; white light interferometry; FIBER; GYROSCOPES; CHIP;
D O I
10.1109/JLT.2022.3142266
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Distributed polarization characteristic of Sagnac optical closed loop that composed of two polarizing devices- polarization maintaining fiber coil and Y-waveguide, can directly affect the performance of fiber optic sensors. Several existing methods are applicable for only one device testing at a time, the efficiency is therefore relatively low and the connection quality between devices is unavailable. In this paper, the Sagnac optical closed loop is split into semi-closed loop (SCL) and full-closed loop (FCL) structures. The transmission behavior of polarized optical signal is fully analyzed, and the information of polarization mode crosstalk is positioned and extracted accurately. By conducting one test of SCL and FCL respectively utilizing white light interferometry, the distributed polarization characteristic of both optical devices and connection points can be entirely obtained. The testing results of optical closed loop are highly consistent with single device test and the difference is less than 0.2dB. A good testing stability is demonstrated through ten repeat measurements and the fluctuation is almost around 0.1dB. We believe that the proposed testing method is capable of promoting the assembly of high-performance Sagnac interferometer and the development of fiber optic sensors.
引用
收藏
页码:2548 / 2555
页数:8
相关论文
共 50 条
  • [31] Mode Distribution Measurement of Optical Vortex Beam using Polarization Sagnac Interferometer with Dove Prism
    Nakashima, Kei
    Kobayashi, Hirokazu
    Iwashita, Katsushi
    2017 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2017,
  • [32] Technology of measuring the beat-length of polarization maintain optical fiber based on Sagnac interferometer
    Xu, Chunjiao
    Yang, Yuanhong
    Duan, Weiqian
    Yang, Wei
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2010, 36 (06): : 753 - 756
  • [33] Effect of hybrid optical amplifier in multiwavelength fiber laser utilizing Sagnac loop mirror interferometer
    Sulaiman, Abdul Hadi
    Aden, Abdisamad Ali
    Ismail, Aiman
    Abdullah, Fairuz
    Jamaludin, Md Zaini
    OPTICAL FIBER TECHNOLOGY, 2022, 74
  • [35] An optical microfiber Sagnac interferometer with adjustable transmission
    Lim, Sun Do
    Park, Kyoung Jun
    Kim, Byoung Yoon
    Lee, Kwanil
    Lee, Sang Bae
    2010 CONFERENCE ON OPTICAL FIBER COMMUNICATION OFC COLLOCATED NATIONAL FIBER OPTIC ENGINEERS CONFERENCE OFC-NFOEC, 2010,
  • [36] Sagnac interferometer based optical coherence tomography
    Shalaby, Abdulrahman M.
    Shalaby, Mohamed
    AIN SHAMS ENGINEERING JOURNAL, 2024, 15 (03)
  • [37] OPTICAL FIBER SWITCH EMPLOYING A SAGNAC INTERFEROMETER
    FARRIES, MC
    PAYNE, DN
    APPLIED PHYSICS LETTERS, 1989, 55 (01) : 25 - 26
  • [38] Optical throughput of modified Sagnac imaging interferometer
    School of Science, Xi'an University of Technology, Xi'an 710048, China
    不详
    Guangxue Xuebao, 2007, 8 (1490-1493):
  • [39] OPTICAL SENSOR FOR CLOSED-LOOP MECHANICAL TESTING
    HARTLEY, CS
    OPTICAL ENGINEERING, 1982, 21 (04) : 718 - 720
  • [40] Balanced polarization maintaining fiber Sagnac interferometer vibration sensor
    Wada, Kenji
    Narui, Hirokazu
    Yamamoto, Daiki
    Matsuyama, Tetsuya
    Horinaka, Hiromichi
    OPTICS EXPRESS, 2011, 19 (22): : 21467 - 21474