Distributed Polarization Characteristic Testing for Optical Closed Loop of Sagnac Interferometer

被引:4
|
作者
Zhang, Haoliang [1 ,2 ]
Yuan, Yonggui [1 ,2 ]
Zhu, Yunlong [1 ,2 ]
Dang, Fanyang [1 ,2 ]
Yu, Zhangjun [3 ,4 ,5 ]
Yang, Jun [3 ,4 ,5 ]
Wang, Yuncai [3 ,4 ,5 ]
Qin, Yuwen [3 ,4 ,5 ]
机构
[1] Harbin Engn Univ, Key Lab Fiber Integrated Opt, Minist Educ China, Harbin 150001, Peoples R China
[2] Harbin Engn Univ, Coll Phys & Optoelect Engn, Harbin 150001, Peoples R China
[3] Univ Technol, Adv Inst Photon Technol, Guangzhou 510006, Peoples R China
[4] Univ Technol, Sch Informat Engn Guangdong, Guangzhou 510006, Peoples R China
[5] Guangdong Prov Key Lab Photon Informat Technol, Guangzhou 510006, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical interferometry; Optical polarization; Optical fibers; Optical fiber sensors; Optical crosstalk; Sagnac interferometers; Adaptive optics; Distributed polarization characteristic; optical closed loop; Sagnac interferometer; white light interferometry; FIBER; GYROSCOPES; CHIP;
D O I
10.1109/JLT.2022.3142266
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Distributed polarization characteristic of Sagnac optical closed loop that composed of two polarizing devices- polarization maintaining fiber coil and Y-waveguide, can directly affect the performance of fiber optic sensors. Several existing methods are applicable for only one device testing at a time, the efficiency is therefore relatively low and the connection quality between devices is unavailable. In this paper, the Sagnac optical closed loop is split into semi-closed loop (SCL) and full-closed loop (FCL) structures. The transmission behavior of polarized optical signal is fully analyzed, and the information of polarization mode crosstalk is positioned and extracted accurately. By conducting one test of SCL and FCL respectively utilizing white light interferometry, the distributed polarization characteristic of both optical devices and connection points can be entirely obtained. The testing results of optical closed loop are highly consistent with single device test and the difference is less than 0.2dB. A good testing stability is demonstrated through ten repeat measurements and the fluctuation is almost around 0.1dB. We believe that the proposed testing method is capable of promoting the assembly of high-performance Sagnac interferometer and the development of fiber optic sensors.
引用
收藏
页码:2548 / 2555
页数:8
相关论文
共 50 条
  • [1] Polarization Dependence Suppression of Optical Fiber Grating Sensor in a π-Shifted Sagnac Loop Interferometer
    Son, Jaebum
    Lee, Min-Kyoung
    Jeong, Myung Yung
    Kim, Chang-Seok
    SENSORS, 2010, 10 (05): : 4373 - 4380
  • [2] POLARIZATION SAGNAC INTERFEROMETER
    GITELSON, S
    NEWBURGH, RG
    SAKAI, H
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1972, 62 (11) : 1376 - 1376
  • [3] A variable-loop sagnac interferometer for distributed impact sensing
    Fang, XJ
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 1996, 14 (10) : 2250 - 2254
  • [4] Optical microphone based on Sagnac interferometer with polarization maintaining optical fibers
    Markowski, Konrad
    Turkiewicz, Jaroslaw
    Osuch, Tomasz
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2013, 2013, 8903
  • [5] Sagnac loop interferometer using polarization maintaining photonic crystal fiber
    Kim, DH
    Kang, JU
    2005 Conference on Lasers & Electro-Optics (CLEO), Vols 1-3, 2005, : 701 - 703
  • [6] Sagnac loop interferometer based on a hybrid polarization-maintaining fiber
    Kwon, Oh-Jang
    Shim, Young-Bo
    Kim, Ryun Kyung
    Han, Young-Geun
    2010 15TH OPTOELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC), 2010, : 344 - 345
  • [7] Fiber-optic distributed sensing by a two-loop Sagnac interferometer
    Fang, XJ
    OPTICS LETTERS, 1996, 21 (06) : 444 - 446
  • [8] A dual-loop Sagnac interferometer
    马海强
    赵建领
    吴令安
    ChinesePhysicsB, 2009, 18 (07) : 2801 - 2805
  • [9] A dual-loop Sagnac interferometer
    Ma Hai-Qiang
    Zhao Jian-Ling
    Wu Ling-An
    CHINESE PHYSICS B, 2009, 18 (07) : 2801 - 2805
  • [10] Polarization dependence compensation in transmission of chiral elements by use of a π-shifted Sagnac loop interferometer
    Exir, Hourieh
    Golub, Ilya
    PHOTONICS NORTH 2012, 2012, 8412