Case Study on Tempered Glass with the Sprinkler Protection as Fire Partition of the Shops

被引:0
|
作者
Wang Dong [1 ]
Lu Shichang [2 ]
机构
[1] Fuxin City Taiping Dist Publ Secur Fire Brigade, Fuxin 123003, Peoples R China
[2] Minist Publ Secur, Tianjin Fire Res Inst, Tianjin 300381, Peoples R China
关键词
large commercial complex; indoor pedestrian street; shop; performance - based fire design; fire scenarios; fire partition; sprinkler system; tempered glass;
D O I
暂无
中图分类号
TD [矿业工程];
学科分类号
0819 ;
摘要
This paper takes a large commercial complex for the engineering case, according to the problem that the solid wall is more difficultly adopt between the indoor pedestrian street and shops, the feasibility of using sprinkler protected tempered glass as the fire partition has been studied with the application of performance based fire design method, the corresponding fire scenarios have been set to calculate the temperature and radiation flux of the glass surface, and the calculated results are compared with the safety performance criterion. The result shows that the water curtain formed by automatic sprinkler system can effectively prevent heat or fire spread, greatly reduce glass front back fire surface temperature and radiant heat flux, so the tempered glass with the reasonable sprinkler protection can be used as the fire partition to separate the shops from the indoor pedestrian street.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [21] The Response Time of Different Sprinkler Glass Bulbs in a Residential Room Fire Scenario
    Arvidson, Magnus
    FIRE TECHNOLOGY, 2018, 54 (05) : 1265 - 1282
  • [22] Experimental study on fallout behaviour of tempered glass facades with different frame insulation conditions in an enclosure fire
    Wang, Yu
    Sun, Jinhua
    He, Linghui
    Wang, Qingsong
    Rush, David
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2019, 37 (03) : 3889 - 3898
  • [23] Research on fire protection methods and a case study "Futurum"
    Outinen, J.
    Samec, J.
    Sokol, Z.
    STEEL STRUCTURES AND BRIDGES 2012 - 23RD CZECH AND SLOVAK INTERNATIONAL CONFERENCE, 2012, 40 : 339 - 344
  • [24] Experimental study on failure mechanism of point-supported tempered glass panels under fire conditions
    Yin, Fei
    Liu, Meiyu
    Bai, Yin
    Zhai, Jianlei
    Zhang, Youzhen
    Yang, Lu
    STRUCTURES, 2021, 30 : 495 - 502
  • [25] The Response Time of Different Sprinkler Glass Bulbs in a Residential Room Fire Scenario
    Magnus Arvidson
    Fire Technology, 2018, 54 : 1265 - 1282
  • [26] Fire Test: The World's largest Fire Testing of a Fire Protection Glass
    不详
    Bauphysik, 2016, 38 (06) : 409 - +
  • [27] A STUDY OF NICKEL SULFIDE STONES IN TEMPERED GLASS
    BARRY, JC
    ULTRAMICROSCOPY, 1993, 52 (3-4) : 297 - 305
  • [28] Measuring modified glass bulb sprinkler thermal response in plunge and compartment fire experiments
    Frank, Kevin
    Spearpoint, Michael
    Baker, Greg
    Wade, Colleen
    Collier, Peter
    Fleischmann, Charles
    FIRE SAFETY JOURNAL, 2017, 91 : 662 - 670
  • [29] Fire protection in the Neckar-1 nuclear generating unit backfitting sprinkler systems
    Wiechers, R
    Burgel, HG
    ATOMWIRTSCHAFT-ATOMTECHNIK, 1995, 40 (06): : 390 - 391
  • [30] Experimental study on fire extinguishing characteristics of Automatic sprinkler system
    Wu, Fan
    Cui, Yongyi
    Qu, Fang
    Mai, Lei
    PROCEEDINGS 2015 SIXTH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS DESIGN AND ENGINEERING APPLICATIONS ISDEA 2015, 2015, : 389 - 392