Case Study on Tempered Glass with the Sprinkler Protection as Fire Partition of the Shops

被引:0
|
作者
Wang Dong [1 ]
Lu Shichang [2 ]
机构
[1] Fuxin City Taiping Dist Publ Secur Fire Brigade, Fuxin 123003, Peoples R China
[2] Minist Publ Secur, Tianjin Fire Res Inst, Tianjin 300381, Peoples R China
关键词
large commercial complex; indoor pedestrian street; shop; performance - based fire design; fire scenarios; fire partition; sprinkler system; tempered glass;
D O I
暂无
中图分类号
TD [矿业工程];
学科分类号
0819 ;
摘要
This paper takes a large commercial complex for the engineering case, according to the problem that the solid wall is more difficultly adopt between the indoor pedestrian street and shops, the feasibility of using sprinkler protected tempered glass as the fire partition has been studied with the application of performance based fire design method, the corresponding fire scenarios have been set to calculate the temperature and radiation flux of the glass surface, and the calculated results are compared with the safety performance criterion. The result shows that the water curtain formed by automatic sprinkler system can effectively prevent heat or fire spread, greatly reduce glass front back fire surface temperature and radiant heat flux, so the tempered glass with the reasonable sprinkler protection can be used as the fire partition to separate the shops from the indoor pedestrian street.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [1] Experimental study on car fire in garage under sprinkler protection
    Liu Yongjin
    Shen Shifei
    Shu Xueming
    Shao Quan
    Yuan Hongyong
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 791 - 794
  • [2] Full-Scale Experimental Study on the Integrity of Tempered Glass Protected by Different Sprinkler Systems in High-Rise Building Fire
    Dong Wang
    Xiaoyu Ju
    Jia Gui
    Yaqiang Jiang
    Zhizuan Zhou
    Xiaodong Zhou
    Junjun Liu
    Lizhong Yang
    Fire Technology, 2023, 59 : 1465 - 1488
  • [3] Full-Scale Experimental Study on the Integrity of Tempered Glass Protected by Different Sprinkler Systems in High-Rise Building Fire
    Wang, Dong
    Ju, Xiaoyu
    Gui, Jia
    Jiang, Yaqiang
    Zhou, Zhizuan
    Zhou, Xiaodong
    Liu, Junjun
    Yang, Lizhong
    FIRE TECHNOLOGY, 2023, 59 (04) : 1465 - 1488
  • [4] Experimental study for laminated glass composed of tempered fire resistance glass exposed to standard heating
    Suzuki K.
    Hisada T.
    Sato A.
    Ohmiya Y.
    Journal of Environmental Engineering (Japan), 2018, 83 (747): : 415 - 424
  • [5] Glass partition walls as fire protection elements in a listed building: A new district arises
    El Ahwany, Claudia
    Technische Sicherheit, 2021, 11 (5-6): : 29 - 31
  • [6] Fire protection: Dormitory sprinkler retrofit laws fall short
    ENR (Engineering News-Record), 2000, 245 (04):
  • [7] A comparative study of statistical methods for critical parameters at tempered glass fallout in an enclosure fire
    Xie, Qimiao
    Wang, Tao
    Guo, Shuaishuai
    Ma, Chao
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 266
  • [8] Experimental and numerical study of the interaction between tempered glass fallout and enclosure fire dynamics
    Li, Xiaoqing
    Wang, Yu
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 201
  • [9] Experimental and numerical study of sprinkler fire protection systems: Effect of initial pressure on system performance
    Cable, A.
    Chetehouna, K.
    Gascoin, N.
    Settar, A.
    Van Herpe, K.
    Kadoche, M.
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2019, 60 : 76 - 86
  • [10] Numerical Study of the Transient Two-phase Flow within Sprinkler Fire Protection Systems
    Cable, A.
    Chetehouna, K.
    Gascoin, N.
    Van Herpe, K.
    Marco, J-F.
    INTERNATIONAL CONFERENCE OF NUMERICAL ANALYSIS AND APPLIED MATHEMATICS (ICNAAM 2017), 2018, 1978