Reduction of BOLD interference in pseudo-continuous arterial spin labeling: towards quantitative fMRI

被引:2
|
作者
Warnock, Geoffrey [1 ]
Oezbay, Pinar S. [2 ,3 ,4 ,5 ]
Kuhn, Felix P. [2 ]
Nanz, Daniel [2 ]
Buck, Alfred [1 ]
Boss, Andreas [2 ]
Rossi, Cristina [2 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Nucl Med, Zurich, Switzerland
[2] Univ Zurich, Inst Diagnost & Intervent Radiol, Univ Hosp Zurich, Raemistr 100, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Zurich, Switzerland
[5] NINDS, Adv MRI Sect, Lab Funct & Mol Imaging, NIH, Bldg 36,Rm 4D04, Bethesda, MD 20892 USA
来源
关键词
Arterial spin labelling; cerebral blood flow measurement; MRI; positron emission tomography; CEREBRAL-BLOOD-FLOW; POSITRON-EMISSION-TOMOGRAPHY; PERFUSION MRI; FIELD-STRENGTH; WHOLE-BRAIN; 3.0; T; CAFFEINE; ECHO; PET; SENSITIVITY;
D O I
10.1177/0271678X17704785
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fluctuations in blood-oxygenation level dependent (BOLD) signal and perfusion affect the quantification of changes in cerebral blood flow (CBF), coupled to neuronal activity, in arterial spin labeling (ASL). Subtraction methods for control and labeled MR images (i.e. pair-wise, surround subtraction, and subtraction of sinc-interpolated images), postulated to mitigate this interference in pseudo-continuous ASL (pCASL), were evaluated by comparison with quantitative O-15-water PET. At rest, a good agreement in the CBF values was found between PET and MRI for each of the subtraction methods. Stimulation of the visual system resulted in a regional CBF increase in the occipital lobe, which was detectable in both modalities. Bland-Altman analysis showed a systematic underestimation of the CBF values during activation in MRI. Evaluation of the relative CBF change induced by neuronal stimulation showed good inter-modality agreement for the three subtraction methods. Perfusion data obtained with each subtraction method followed the stimulation paradigm without significant differences in the correlation patterns or in the time lag between stimulation and perfusion response. Comparison to the gold standard confirmed the detectability of a neuronal stimulation pattern by pCASL. The results indicate that the combined use of background suppression and short TE reduces the BOLD-weighting in the pCASL signal.
引用
收藏
页码:847 / 856
页数:10
相关论文
共 50 条
  • [31] Pseudo-continuous arterial spin labeling MRI study of patients with obsessive-compulsive disorder
    Ota, Miho
    Kanie, Ayako
    Kobayashi, Yuki
    Nakajima, Aiichiro
    Sato, Noriko
    Horikoshi, Masaru
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2020, 303
  • [32] Feasibility of Using Pseudo-Continuous Arterial Spin Labeling Perfusion in a Geriatric Population at 1.5 Tesla
    Sigurdsson, Sigurdur
    Forsberg, Lars
    Aspelund, Thor
    van der Geest, Rob J.
    van Buchem, Mark A.
    Launer, Lenore J.
    Gudnason, Vilmundur
    van Osch, Matthias J.
    PLOS ONE, 2015, 10 (12):
  • [33] Model-based super-resolution reconstruction for pseudo-continuous Arterial Spin Labeling
    Beirinckx, Quinten
    Bladt, Piet
    van der Plas, Merlijn C. E.
    van Osch, Matthias J. P.
    Jeurissen, Ben
    den Dekker, Arnold J.
    Sijbers, Jan
    NEUROIMAGE, 2024, 286
  • [34] Effect of background suppression and motion correction on pseudo-continuous arterial spin labeling CBF measurement
    Ibaraki, M.
    Nakamura, K.
    Toyoshima, H.
    Takahashi, K.
    Matsubara, K.
    Pfeuffer, J.
    Kuribayashi, H.
    Kinoshita, T.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 : 359 - 360
  • [35] Pseudo-continuous arterial spin labeling technique for measuring CBF dynamics with high temporal resolution
    Silva, AC
    Kim, SG
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (03) : 425 - 429
  • [36] Neural plasticity secondary to carpal tunnel syndrome: a pseudo-continuous arterial spin labeling study
    Xue Deng
    Phoebe Lai-Heung Chau
    Suk-Yee Chiu
    Kwok-Pui Leung
    Yong Hu
    Wing-Yuk Ip
    NeuralRegenerationResearch, 2021, 16 (01) : 158 - 165
  • [37] Interpulse phase corrections for unbalanced pseudo-continuous arterial spin labeling at high magnetic field
    Hirschler, Lydiane
    Debacker, Clement S.
    Voiron, Jerome
    Koehler, Sascha
    Warnking, Jan M.
    Barbier, Emmanuel L.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1314 - 1324
  • [38] Improving the robustness of pseudo-continuous arterial spin labeling to off-resonance and pulsatile flow velocity
    Zhao, Li
    Vidorreta, Marta
    Soman, Salil
    Detre, John A.
    Alsop, David C.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (04) : 1342 - 1351
  • [39] Designing and comparing optimized pseudo-continuous Arterial Spin Labeling protocols for measurement of cerebral blood flow
    Woods, Joseph G.
    Chappell, Michael A.
    Okell, Thomas W.
    NEUROIMAGE, 2020, 223
  • [40] Cerebral Blood Flow Quantification Utilizing Pseudo-Continuous Arterial Spin Labeling in Acute Stroke Patients
    Hernandez, Daymara A.
    Bokkers, Reinoud P.
    Mirasol, Raymond V.
    Luby, Marie
    Henning, Erica C.
    Merino, Jose G.
    Warach, Steven
    Latour, Lawrence L.
    STROKE, 2011, 42 (03) : E286 - E286