The effects of computed tomography scanner parameters on the quality of the reverse triangular surface model of the fibula

被引:2
|
作者
Hayat, Nasir [1 ]
Ahmad, Mushtaq [1 ]
机构
[1] UET, Fac Mech Engn, Lahore, Pakistan
关键词
Triangular surface model; Accuracy; Biomedical implant; Computed tomography (CT); Complex-shaped objects; Fibula; ACCURACY; BONE;
D O I
10.1007/s40430-015-0372-y
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study investigates the effects of computed tomography (CT) parameters on the quality and size of the reverse triangular surface model with an objective of obtaining an accurate 3D triangular surface model of complex-shaped customized objects for reverse engineering and many other applications such as surgical planning and finite element analysis. For this purpose, the fibula of a human knee joint was CT scanned by changing various parameters (slice thickness, slice spacing, pixel size, X-ray tube current and helical pitch) over wide ranges. Three-dimensional triangular surface models were created from point cloud data extracted from the CT image data. To assess the influences of scanning parameters on the surface quality and accuracy, the resulting surface models were qualitatively compared based on various anatomical features. Statistical analysis was used to quantify the deviations of surface models with different scanning parameter levels from the reference CT surface model. The results show that these parameters to a varying degree affect the surface quality, reproduction of various anatomical details and size of the resulting surface model. Moreover, these parameters are highly dependent on each other. Interactive effects of these parameters have been discussed and recommendations have been made for parameter settings. The results of the study would help to improve the accuracy of the 3D surface models required for customized implants and other applications.
引用
收藏
页码:21 / 31
页数:11
相关论文
共 50 条
  • [1] The effects of computed tomography scanner parameters on the quality of the reverse triangular surface model of the fibula
    Nasir Hayat
    Mushtaq Ahmad
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2016, 38 : 21 - 31
  • [2] A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging
    De Cock, Jens
    Zanca, Federica
    Canning, John
    Pauwels, Ruben
    Hermans, Robert
    EUROPEAN RADIOLOGY, 2015, 25 (07) : 1891 - 1900
  • [3] A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging
    Jens De Cock
    Federica Zanca
    John Canning
    Ruben Pauwels
    Robert Hermans
    European Radiology, 2015, 25 : 1891 - 1900
  • [4] IMPACT OF A FAST SCANNER ON IMAGE QUALITY IN PEDIATRIC COMPUTED-TOMOGRAPHY
    ANDERSON, RE
    RADMEHR, A
    OSBORN, AG
    WING, SD
    RADIOLOGY, 1980, 134 (01) : 251 - 252
  • [5] ACCURACY IN CONTOURING OF SMALL AND LOW CONTRAST LESIONS: COMPARISON BETWEEN DIAGNOSTIC QUALITY COMPUTED TOMOGRAPHY SCANNER AND COMPUTED TOMOGRAPHY SIMULATION SCANNER A PHANTOM STUDY
    Wong, W. K. R.
    Ho, Y. W.
    Yu, S. K.
    Lam, W. W.
    Geng, H.
    Liu, S. F.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S382 - S382
  • [6] Accuracy in contouring of small and low contrast lesions: Comparison between diagnostic quality computed tomography scanner and computed tomography simulation scanner-A phantom study
    Ho, Yick Wing
    Wong, Wing Kei Rebecca
    Yu, Siu Ki
    Lam, Wai Wang
    Geng, Hui
    MEDICAL DOSIMETRY, 2012, 37 (04) : 401 - 405
  • [7] Polymer gel dosimetry on a multislice computed tomography scanner: Effect of changing parameters on CTDI
    Hill, B.
    Venning, A. J.
    Baldock, C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2008, 24 (03): : 149 - 158
  • [8] Effects of Dose Reduction on Diagnostic Image Quality of Coronary Computed Tomography Angiography in Children Using a Third-Generation Dual-Source Computed Tomography Scanner
    Rashed, Moustafa
    Banka, Puja
    Barthur, Ashita
    MacDougal, Robert D.
    Rathod, Rahul H.
    Powell, Andrew J.
    Prakash, Ashwin
    AMERICAN JOURNAL OF CARDIOLOGY, 2018, 122 (07): : 1260 - 1264
  • [9] Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner
    Kakinuma, Ryutaro
    Moriyama, Noriyuki
    Muramatsu, Yukio
    Gomi, Shiho
    Suzuki, Masahiro
    Nagasawa, Hirobumi
    Kusumoto, Masahiko
    Aso, Tomohiko
    Muramatsu, Yoshihisa
    Tsuchida, Takaaki
    Tsuta, Koji
    Maeshima, Akiko Miyagi
    Tochigi, Naobumi
    Watanabe, Shun-ichi
    Sugihara, Naoki
    Tsukagoshi, Shinsuke
    Saito, Yasuo
    Kazama, Masahiro
    Ashizawa, Kazuto
    Awai, Kazuo
    Honda, Osamu
    Ishikawa, Hiroyuki
    Koizumi, Naoya
    Komoto, Daisuke
    Moriya, Hiroshi
    Oda, Seitaro
    Oshiro, Yasuji
    Yanagawa, Masahiro
    Tomiyama, Noriyuki
    Asamura, Hisao
    PLOS ONE, 2015, 10 (09):
  • [10] Body surface area measurement in laboratory miniature pigs using a computed tomography scanner
    Itoh, Tadashi
    Kawabe, Mifumi
    Nagase, Takahiko
    Endo, Katsumi
    Miyoshi, Masafumi
    Miyahara, Kazuro
    JOURNAL OF TOXICOLOGICAL SCIENCES, 2016, 41 (05): : 637 - 644