Numerical and Experimental Analysis of Flow Pattern, Pressure Drop and Collection Efficiency in a Cyclone with a Square Inlet and Different Dimensions of a Vortex Finder

被引:11
|
作者
Wojtowicz, Ryszard [1 ]
Wolak, Pawel [2 ]
Wojtowicz-Wrobel, Agnieszka [3 ]
机构
[1] Cracow Univ Technol, Inst Thermal & Proc Engn, Div Ind Equipment & Fluid Mech, Al Jana Pawla II 37, PL-31864 Krakow, Poland
[2] Air Liquide Global E&C Solut Poland SA, Ul Mogilska 41, PL-31545 Krakow, Poland
[3] Cracow Univ Technol, Fac Architecture, Dept Spatial Planning Urban & Rural Design, Ul Warszawska 24, PL-31155 Krakow, Poland
关键词
dust removal; cyclone separator; vortex finder; gas flow pattern; pressure drop; CFD simulations; CTA mesaurements; PERFORMANCE EVALUATION; POWER-CONSUMPTION; SIMULATION; SEPARATOR; FIELD; DUST; CFD; HYDRODYNAMICS; LENGTH;
D O I
10.3390/en14010111
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The paper presents results of numerical simulations and experimental investigations of a cyclone with a square inlet and different dimensions of a vortex finder. Investigations were conducted for five, different cyclone models. The main goal of the research was to determine the influence of cyclone vortex finder geometry (diameter, length) on key parameters for a cyclone operation, such as: gas flow pattern, gas velocity and pressure distribution, pressure drop and collection efficiency. The analysis of flow pattern inside the cyclone was carried out with the use of CFD (Computational Fluid Dynamics) simulations, verified using CTA (Constant Temperature Anemometry). Similarly, pressure distributions, pressure drop and collection efficiency for cyclones were determined numerically and with measurements. The study demonstrated that dimensions of the vortex finder have a significant effect on a cyclone performance. The numerical visualisations of flow showed some unfavorable and beneficial effects and phenomena that may occur in cyclones. Moreover, the smallest pressure drop (305 Pa) was predicted for the cyclone with a maximum diameter of the vortex finder (De = 0.105 m), the largest (358 Pa) when this diameter was the smallest (De = 0.075 m). The tests did not show any significant influence of the vortex finder length on the pressure drop in a cyclone. A different tendency was observed in the case of collection efficiency. The maximum value of this parameter (89.5%) was predicted for the cyclone with the shortest vortex finder (s = 0.060 m), minimum (85.5%) when the vortex finder was the longest (s = 0.220 m). In this case, however, tests did not show a significant impact of an outlet diameter on the collection efficiency. Results and conclusions presented in this paper can be practically used for design optimization of cyclone separators, and also to select their operating parameters.
引用
收藏
页数:20
相关论文
共 43 条
  • [41] Effect of gas-induced inlet design on flow pattern and energy loss for small-scale countercurrent vortex reactor: Numerical simulation and experimental investigation
    Liu, Qian
    Zhao, Bingtao
    Li, Huimei
    Li, Xuan
    Su, Yaxin
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2022, 182 : 371 - 380
  • [42] Experimental and Numerical Analysis of Multi-Hole Orifice Flow Meter: Investigation of the Relationship between Pressure Drop and Mass Flow Rate
    Tomaszewski, Adam
    Przybylinski, Tomasz
    Lackowski, Marcin
    SENSORS, 2020, 20 (24) : 1 - 23
  • [43] Experimental investigation of different sub-regimes in horizontal stratified and intermittent gas-liquid two-phase flow: Flow map and analysis of pressure drop fluctuations
    Bouderbal, Amina
    Salhi, Yacine
    Arabi, Abderraouf
    Si-Ahmed, El-Khider
    Legrand, Jack
    Arhaliass, Abdellah
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2024, 210 : 407 - 424