CROSS-SECTIONAL MEASUREMENT OF MICRO PARTICLES VOLUME FRACTION IN A MICROCHANNEL BY USING CAPACITANCE TOMOGRAPHY SENSING

被引:0
|
作者
Othman, Nur Tantiyani Ali [1 ]
Obara, Hiromichi [2 ]
Choi, Je-Eun [1 ]
Takei, Masahiro [1 ]
机构
[1] Chiba Univ, Grad Sch Mech Engn, Artificial Syst Sci Div, Inage Ku, 1-33 Yayoi, Chiba, Japan
[2] Tokyo Metropolitan Univ, Grad Sch Sci & Engn, Hachioji, Tokyo, Japan
基金
日本科学技术振兴机构;
关键词
RADIAL MIGRATION; POISEUILLE FLOW; RIGID SPHERES; MOTION; SUSPENSIONS; COUETTE; FLUID; TUBES;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this study, a cross-sectional capacitance is measured in a microchannel with 12 multi-layered electrodes. The cross-sectional capacitance of polystyrene particles and deionized water is measured at upstream and downstream microchannel. Based on the measured cross-sectional capacitance, the particle volume fraction is calculated at three area measurements with different electrode pair. The three area measurements are at the adjacent pair, horizontal pair and vertical pair. The particle volume fraction at the adjacent pair area is almost same and higher at upstream and downstream cross-section. While at the vertical and horizontal pair areas, the particle volume fraction increased from upstream to downstream cross-section around 1.0-9.3% at electrode pair near the walls whilst decreased 0.4-0.96% at electrode pair near the center streamlines. It shows the particles are more attracted to migrate to the equilibrium position at near to the walls. The particles migration induced by inertial lift forces is reflected to Serge-Silberberg phenomenon where the particles are distributed and transverse from the center streamlines of fluid flowing to the area near the walls.
引用
收藏
页码:769 / +
页数:2
相关论文
共 50 条
  • [41] Metabolic evaluation and measurement of ovarian volume in polycystic ovary sydrome: a cross-sectional observational study
    Evran, Mehtap
    Balli, Huseyin Tugsan
    Sert, Murat
    Tetiker, Bekir Tamer
    CUKUROVA MEDICAL JOURNAL, 2016, 41 (01): : 28 - 33
  • [42] Measurement of cross-sectional velocity distribution of pneumatically conveyed particles in a square-shaped pipe through electrostatic sensing and Gaussian process regression
    Wang, Yongyue
    Wang, Lijuan
    Qian, Xiangchen
    Yan, Yong
    2022 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2022), 2022,
  • [43] Investigation of the riser cross-sectional aspect ratio effect on the flow dynamics in circulating fluidized beds by electrical capacitance tomography
    Tu, Qiuya Y.
    Wang, Haigang G.
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2020, 42 (04) : 655 - 665
  • [44] Inverse Normalization Method for Cross-Sectional Imaging and Velocimetry of Two-Phase Flows Based on Electrical Capacitance Tomography
    Chowdhury, Shah
    Marashdeh, Qussai M.
    Teixeira, Fernando L.
    IEEE SENSORS LETTERS, 2018, 2 (01)
  • [45] Void Fraction Measurement in Oil-Gas Transportation Pipeline Using an Improved Electrical Capacitance Tomography System
    牛刚
    贾志海
    王经
    Chinese Journal of Chemical Engineering, 2004, (04) : 20 - 25
  • [46] Void fraction measurement in oil-gas transportation pipeline using an improved electrical capacitance tomography system
    Niu, G
    Jia, ZH
    Wang, J
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2004, 12 (04) : 476 - 481
  • [47] DETERMINATION OF LEFT-VENTRICULAR VOLUME AND EJECTION FRACTION IN CORONARY-ARTERY DISEASE BY CROSS-SECTIONAL ECHOCARDIOGRAPHY
    ERBEL, R
    SCHWEIZER, P
    MEYER, J
    GRENNER, H
    KREBS, W
    EFFERT, S
    ZEITSCHRIFT FUR KARDIOLOGIE, 1980, 69 (01): : 52 - 61
  • [48] Measurement of Soot Temperature and Volume Fraction of Axisymmetric Ethylene Laminar Flames Using Hyperspectral Tomography
    Liu, Huawei
    Zheng, Shu
    Zhou, Huaichun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (02) : 315 - 324
  • [49] Electrical Capacitance Volume Tomography Static Imaging using Compressive Sensing with l1 Sparse Recovery
    Andryani, Nur Afny C.
    Sudiana, Dodi
    Gunawan, Dadang
    2017 INTERNATIONAL CONFERENCE ON SIGNALS AND SYSTEMS (ICSIGSYS), 2017, : 50 - 56
  • [50] Bone volume and regional density of the central tarsal bone detected using computed tomography in a cross-sectional study of adult racing greyhounds
    Thompson, D. J.
    Cave, N. J.
    Bridges, J. P.
    Reuvers, K.
    Owen, M. C.
    Firth, E. C.
    NEW ZEALAND VETERINARY JOURNAL, 2012, 60 (05) : 278 - 284