Self-interference fluorescence microscopy with three-phase detection for depth-resolved confocal epi-fluorescence imaging

被引:0
|
作者
Braaf, Boy [1 ,2 ]
De Boer, Johannes F. [1 ]
机构
[1] Vrije Univ Amsterdam, Dept Phys & Astron, LaserLaB, De Boelelaan 1081, NL-1081 HV Amsterdam, Netherlands
[2] Massachusetts Gen Hosp, Wellman Ctr Photomed, 50 Blossom St, Boston, MA 02114 USA
来源
OPTICS EXPRESS | 2017年 / 25卷 / 06期
关键词
OPTICAL COHERENCE TOMOGRAPHY; IN-VIVO FLUORESCENCE; SPECTROSCOPY; LIGHT; RESOLUTION;
D O I
10.1364/OE.25.006475
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Three-dimensional confocal fluorescence imaging of in vivo tissues is challenging due to sample motion and limited imaging speeds. In this paper a novel method is therefore presented for scanning confocal epi-fluorescence microscopy with instantaneous depthsensing based on self-interference fluorescence microscopy (SIFM). A tabletop epifluorescence SIFM setup was constructed with an annular phase plate in the emission path to create a spectral self-interference signal that is phase-dependent on the axial position of a fluorescent sample. A Mach-Zehnder interferometer based on a 3 x 3 fiber-coupler was developed for a sensitive phase analysis of the SIFM signal with three photon-counter detectors instead of a spectrometer. The Mach-Zehnder interferometer created three intensity signals that alternately oscillated as a function of the SIFM spectral phase and therefore encoded directly for the axial sample position. Controlled axial translation of fluorescent microsphere layers showed a linear dependence of the SIFM spectral phase with sample depth over axial image ranges of 500 mu m and 80 mu m (3.9 x Rayleigh range) for 4 x and 10 x microscope objectives respectively. In addition, SIFM was in good agreement with optical coherence tomography depth measurements on a sample with indocyanine green dye filled capillaries placed at multiple depths. High-resolution SIFM imaging applications are demonstrated for fluorescence angiography on a dye-filled capillary blood vessel phantom and for autofluorescence imaging on an ex vivo fly eye.
引用
收藏
页码:6475 / 6496
页数:22
相关论文
共 50 条
  • [41] Characterization of swelling of a polymeric coating for DNA microarray applications using spectral self-interference fluorescence microscopy
    Yalcin, Ayca
    Damin, Francesco
    Oezkumur, I. Emre
    di Carlo, Gabriele
    Goldberg, Bennett B.
    Chiari, Marcella
    Uenlue, M. Selim
    2007 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2007, : 220 - +
  • [42] Multispectral Stokes/Mueller Detection Module for Multiphoton/Fluorescence Confocal Scanning Imaging Microscopy
    Le Gratiet, Aymeric
    Marongiu, Riccardo
    Ashraf, Muhammad Waseem W.
    Mohebi, Ali
    Callegari, Fabio
    Bianchini, Paolo
    Diaspro, Alberto
    BIOPHYSICAL JOURNAL, 2021, 120 (03) : 355A - 355A
  • [43] Three-Dimensional Imaging of Plant Cell Wall Deconstruction Using Fluorescence Confocal Microscopy
    Zoghlami, Aya
    Refahi, Yassin
    Terryn, Christine
    Paes, Gabriel
    SUSTAINABLE CHEMISTRY, 2020, 1 (02): : 75 - 85
  • [44] Application of fluorescence resonance energy transfer resolved by fluorescence lifetime imaging microscopy for the detection of enterovirus 71 infection in cells
    Ghukasyan, Vladimir
    Hsu, Yueh-Ying
    Kung, Szu-Hao
    Kao, Fu-Jen
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (02)
  • [45] Super-Resolved FRET Imaging by Confocal Fluorescence-Lifetime Single-Molecule Localization Microscopy
    Zaza, Cecilia
    Chiarelli, German
    Zweifel, Ludovit P.
    Pilo-Pais, Mauricio
    Sisamakis, Evangelos
    Barachati, Fabio
    Stefani, Fernando D.
    Acuna, Guillermo P.
    SMALL METHODS, 2023, 7 (07)
  • [46] Mapping the Spatiotemporal Heterogeneity of Biomolecules Concentration, Mobility and Local Environment in Live Cells using Quantitative Time-Resolved Confocal Fluorescence Microscopy Imaging Without Scanning and Fluorescence Lifetime Imaging Microscopy
    Oasa, Sho
    Krmpot, Aleksandar
    Nikolic, Stanko
    Terenius, Lars
    Rigler, Rudolf
    Vukojevic, Vladana
    BIOPHYSICAL JOURNAL, 2020, 118 (03) : 307A - 307A
  • [47] Depth-resolved spectral imaging of rabbit oesophageal tissue based on two-photon excited fluorescence and second-harmonic generation
    Chen, Jianxin
    Zhuo, Shuangmu
    Chen, Rong
    Jiang, Xingshan
    Xie, Shusen
    Zou, Qilian
    NEW JOURNAL OF PHYSICS, 2007, 9
  • [48] Enhanced quantitative phase imaging in self-interference digital holographic microscopy using an electrically focus tunable lens
    Schubert, Robin
    Vollmer, Angelika
    Ketelhut, Steffi
    Kemper, Bjoern
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (12): : 4213 - 4222
  • [49] Detection and identification of single molecules in living cells using spectrally resolved fluorescence lifetime imaging microscopy
    Knemeyer, JP
    Herten, DP
    Sauer, M
    ANALYTICAL CHEMISTRY, 2003, 75 (09) : 2147 - 2153
  • [50] Quantitative imaging by confocal scanning fluorescence microscopy of protein crystallization via liquid-liquid phase separation
    Vivarès, D
    Kaler, EW
    Lenhoff, AM
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2005, 61 : 819 - 825