Modelling of a Doubly Fed Induction Generator (DFIG) to Study its Control System

被引:0
|
作者
Billah, M. M. [1 ]
Hosseinzadeh, N. [1 ]
Ektesabi, M. M. [1 ]
机构
[1] Swinburne Univ Technol, Fac Engn & Ind Sci, POB 218, Hawthorn, Vic 3122, Australia
关键词
DFIG; Controller; stator flux orientation (SFO); renewable energy;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A fifth order model of a doubly fed induction generator (DFIG) is proposed with stator flux orientation (SFO) vector control. Induction generator equipped with the as-built wind turbine scheme and grid system is modelled in MATLAB/SIMULINK. Different controllable parameters are identified. A control system is designed to improve the stability of the generator, which is connected with the back to back power electronic converter circuits. The converters will facilitate controllability on active and reactive power produced by the wind generator.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Modeling and Control of a Doubly Fed Induction Generator (DFIG) Based Wind Conversion System
    Ghennam, T.
    Berkouk, E. M.
    Francois, B.
    2009 INTERNATIONAL CONFERENCE ON POWER ENGINEERING, ENERGY AND ELECTRICAL DRIVES, 2009, : 496 - +
  • [2] Power System Oscillation Damping Capability of Doubly Fed Induction Generator (DFIG)
    Gurung, Niroj
    Kamalasadan, Sukumar
    2018 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2018,
  • [3] Modelling of doubly-fed induction generator for power system stability study
    Mei, Francoise
    Pal, Bikash C.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 287 - 294
  • [4] Study and control of wind energy conversion system (WECS) based on the doubly fed induction generator (DFIG) connected to the grid
    Selman, Kouadria
    Seifeddine, Belfedhal
    Youcef, Messlem
    El Madjid, Berkouk
    2014 NINTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2014,
  • [5] Decoupled active and reactive power control of a doubly-fed induction generator (DFIG)
    Dendouga, A.
    Abdessemed, R.
    Bendaas, M. L.
    Chaiba, A.
    2007 MEDITERRANEAN CONFERENCE ON CONTROL & AUTOMATION, VOLS 1-4, 2007, : 1217 - 1221
  • [6] A Sensorless Adaptive Grid Side Control Approach for Doubly Fed Induction Generator (DFIG)
    Nair, Anuprabha R.
    Bhattarai, Rojan
    Kamalasadan, Sukumar
    2019 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2019,
  • [7] Operation Simulation of Doubly Fed Induction Generator (DFIG) as Stand Alone Generator
    Akbar, Fajril
    Syamsuddin, Syarkawi
    Andonal, Novri
    Nazir, Refdinal
    2019 IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2019, : 47 - 52
  • [8] Robust Control of a Doubly Fed Induction Generator (DFIG) Fed by a Direct AC-AC Converter
    Boudjema, Zinelaabidine
    Meroufel, Abdelkader
    Amari, Ahmed
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (12A): : 213 - 221
  • [9] Structural integrity of a Doubly Fed Induction Generator (DFIG) of a wind power system (WPS)
    Ezzahi, Mohammed
    Khafallah, Mohamed
    Majid, Fatima
    IGF WORKSHOP FRACTURE AND STRUCTURAL INTEGRITY, 2018, 9 : 221 - 228
  • [10] Modelling of doubly fed induction generator in a multimachine acsystem with SMES control
    Rahim, Abu H.M.A.
    Nowicki, Edwin P.
    1600, Acta Press (33): : 102 - 108