Power System Oscillation Damping Capability of Doubly Fed Induction Generator (DFIG)

被引:0
|
作者
Gurung, Niroj [1 ]
Kamalasadan, Sukumar [1 ]
机构
[1] Univ North Carolina Charlotte, Dept Elect & Comp Engn, Charlotte, NC 28223 USA
关键词
Doubly-Fed Induction Generator (DFIG); Rotor Side Converter (RSC); Grid Side Converter (GSC); Vector Control (VC); Power System Stabilizer (PSS); Wind Turbine Generator (WTG); Inter-Area Mode (IAM); Supplementary Control (SC);
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The increasing amount of wind power generation essentially replaces the conventional synchronous generators of the power system, thereby, reducing the total inertia of the system. Reduced inertia of the system is expected to hamper the system response during contingencies. It is clear that small signal as well as transient rotor angle stability is be affected by the changing dynamics of the power grid. This paper focuses on the impact of increasing DFIG penetration and techniques to overcome the stability issues using DFIG control. The technique of using modified Rotor Side Converter (RSC) control and Grid Side Converter (GSC) control with a supplementary control loop and their capability to damp the power system oscillation have been investigated using modal analysis and non-linear time-domain analysis. The results are evaluated on Kundur two area four machine test system.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Reduced Order Model Based Optimal Oscillation Damping Controller Design for Doubly Fed Induction Generator (DFIG) Integrated Power Grid
    Gurung, Niroj
    Bhattarai, Rojan
    Kamalasadan, Sukumar
    2018 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2018,
  • [2] Structural integrity of a Doubly Fed Induction Generator (DFIG) of a wind power system (WPS)
    Ezzahi, Mohammed
    Khafallah, Mohamed
    Majid, Fatima
    IGF WORKSHOP FRACTURE AND STRUCTURAL INTEGRITY, 2018, 9 : 221 - 228
  • [3] Oscillation Damping for Wind Energy Conversion System with Doubly Fed Induction Generator Association with Synchronous Generator
    Abo-Elyousr, Farag K.
    Abbas, Hossam S.
    Yousef, Ali M.
    Quynh, Nguyen Vu
    Ali, Ziad M.
    Nazir, Muhammad Shahzad
    ENERGIES, 2020, 13 (19)
  • [4] Influence of doubly-fed induction generator on power system oscillation center migration
    Li, Xinang
    Tang, Fei
    Xie, Jiarui
    Qi, Junfeng
    Guo, Yuhan
    Lin, Zhiyuan
    Liu, Zhuo
    ENERGY REPORTS, 2022, 8 : 792 - 799
  • [5] An Improved Technique of Wind Power Harvesting With a Doubly Fed Induction Generator (DFIG)
    Balow, Writwik
    Sain, Parijat
    Chatterjee, Anindya
    Halder, T.
    2018 IEEE 8TH POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2018,
  • [6] Reactive power capability of a wind turbine with doubly fed induction generator
    Lund, Torsten
    Sorensen, Poul
    Eek, Jarle
    WIND ENERGY, 2007, 10 (04) : 379 - 394
  • [7] Reactive Power Capability of the Wind Turbine with Doubly Fed Induction Generator
    Tian, J.
    Su, C.
    Chen, Z.
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 5312 - 5317
  • [8] Modelling of a Doubly Fed Induction Generator (DFIG) to Study its Control System
    Billah, M. M.
    Hosseinzadeh, N.
    Ektesabi, M. M.
    2010 20TH AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC 2010): POWER QUALITY FOR THE 21ST CENTURY, 2010,
  • [9] A comparative study for reactive power capability of doubly fed induction generator and synchronous generator
    Kumar, Sanjeev
    Singh, Omveer
    Aggarwal, S. K.
    2016 2ND IEEE INTERNATIONAL CONFERENCE ON CONTROL, COMPUTING, COMMUNICATION AND MATERIALS (ICCCCM), 2016,
  • [10] Linear-Quadratic Gaussian based Power Oscillation Damping Controller Design for Doubly Fed Induction Generator
    Gurung, Niroj
    Kamalasadan, Sukumar
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,