Experimental study on the interaction between particulate fouling and precipitation fouling in the fouling process on heat transfer tubes

被引:38
|
作者
Shen, Chao [1 ]
Wang, Yuan [1 ]
Tang, Zhenbo [1 ]
Yao, Yang [1 ]
Huang, Yudong [2 ]
Wang, Xinlei [3 ]
机构
[1] Harbin Inst Technol, Sch Architecture, Minist Ind & Informat Technol, Key Lab Cold Reg Urban & Rural Human Settlement E, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Sch Chem & Chem Engn, Harbin 150001, Heilongjiang, Peoples R China
[3] Univ Illinois, Dept Agr & Biol Engn, Urbana, IL 61081 USA
基金
中国国家自然科学基金;
关键词
Interaction; Particulate fouling; Precipitation fouling; Combined fouling; Heat transfer tube; FERRIC-OXIDE PARTICLES; WATER; ROUGHNESS;
D O I
10.1016/j.ijheatmasstransfer.2019.04.136
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigated the interaction between particulate fouling and precipitation fouling on two different enhanced tubes and a plain tube in a shell-and-tube condenser. Three kinds of fouling, including particulate fouling, precipitation fouling, and combined fouling, were measured continuously for more than 720 h in three individual tests, respectively. For the particulate fouling, three tubes suffered a similar fouling process. The asymptotic fouling resistance of the precipitation fouling on enhanced tubes was lower than on the plain tube. However, for the combined fouling, the enhanced tube with a larger start number experienced the greatest fouling. On the same tube, the asymptotic fouling resistances ranked from least to greatest in the following order: particulate fouling, precipitation fouling, combined fouling; and the durations of the induction period ranked as: particulate fouling, precipitation fouling, combined fouling. As for the combined fouling existent in real cooling water systems, the fouling induction period on the plain tube was longer than that of enhanced tubes. Compared with the particulate fouling (SiO2) and precipitation fouling (CaCO3), which had a high bond strength on the tube surface, the combined fouling was soft and easily removed by flow erosion or collision with big particles during the induction period. This indicated that particles mixed in the water could extend the induction period of combined fouling. However, once the combined fouling started to grow, these particles sticking on the heat transfer surface provided nucleation sites for the crystallization process and, thus, increased the fouling thermal resistance significantly. In addition, the results indicated that the variation profile of the accelerated combined fouling after scaling down is similar to the fouling process in a real system. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1238 / 1250
页数:13
相关论文
共 50 条
  • [41] Fouling, viscosity, & the heat transfer coefficient
    Durand, AA
    CHEMICAL ENGINEERING, 1996, 103 (10) : 153 - &
  • [42] FOULING IN HEAT-TRANSFER EQUIPMENT
    JONES, PP
    CHEMICAL ENGINEER-LONDON, 1972, (259): : 128 - &
  • [43] Numerical Study on Particulate Fouling Characteristics of Flue with a Particulate Fouling Model Considering Deposition and Removal Mechanisms
    Liu, Peng
    Liu, Wei
    Gong, Kexin
    Han, Chengjun
    Zhang, Hong
    Sui, Zhucheng
    Hu, Renguo
    ENERGIES, 2022, 15 (22)
  • [44] Synergism between particulate and microbial fouling on a heat transfer surface using treated sewage water
    Li, Nan
    Yang, Qirong
    Yao, Erren
    Zhang, Ning
    APPLIED THERMAL ENGINEERING, 2019, 150 : 791 - 802
  • [45] Influence of the Apex Angle of Cone-Shaped Tubes on Particulate Fouling of Heat Exchangers
    Abd-Elhady, Mohamed S.
    Rindt, Camilo C. M.
    Van Steenhoven, Anton A.
    HEAT TRANSFER ENGINEERING, 2011, 32 (3-4) : 272 - 281
  • [46] MODELING LIQUID-SIDE PARTICULATE FOULING IN ENHANCED TUBES
    CHAMRA, LM
    WEBB, RL
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1994, 37 (04) : 571 - 579
  • [47] Development and evaluation of vipertex enhanced heat transfer tubes for use in fouling conditions
    D. J. Kukulka
    R. Smith
    J. Zaepfel
    Theoretical Foundations of Chemical Engineering, 2012, 46 : 627 - 633
  • [48] Heat Transfer of Circular Finned Tubes with Nonuniform Operational Fouling of the Interfin Space
    Karlovich T.B.
    Journal of Engineering Physics and Thermophysics, 2018, 91 (5) : 1211 - 1219
  • [49] CFD modeling for prediction of particulate fouling of heat transfer surface in turbulent flow
    Han, Zhimin
    Xu, Zhiming
    Yu, Xiaoyan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 144
  • [50] Development and evaluation of vipertex enhanced heat transfer tubes for use in fouling conditions
    Kukulka, D. J.
    Smith, R.
    Zaepfel, J.
    THEORETICAL FOUNDATIONS OF CHEMICAL ENGINEERING, 2012, 46 (06) : 627 - 633