Accurate determination and certification of bromine in plastic by isotope dilution inductively coupled plasma mass spectrometry

被引:21
|
作者
Ohata, Masaki [1 ]
Miura, Tsutomu [1 ]
机构
[1] Natl Metrol Inst Japan, Inorgan Analyt Chem Div, Inorgan Stand Sect, Tsukuba, Ibaraki 3058563, Japan
关键词
Isotope dilution inductively coupled plasma; mass spectrometry (ID-ICPMS); Bromine analysis in plastic; Microwave acid digestion procedure; Memory effect; Certified reference material (CRM); RoHS directive; CERTIFIED REFERENCE MATERIALS; HEAVY-METAL ANALYSIS; ICP-MS; ORGANIC-COMPOUNDS; HALOGENS; UNCERTAINTY; RESPECT; SAMPLES; SULFUR; LEAD;
D O I
10.1016/j.aca.2014.06.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The accurate analytical method of bromine (Br) in plastic was developed by an isotope dilution inductively coupled plasma mass spectrometry (ID-ICPMS). The figures of merit of microwave acid digestion procedures using polytetrafluoroethylene (PTFE) or quartz vessels were studied and the latter one was suitable for Br analysis since its material was free from Br contamination. The sample dilution procedures using Milli-Q water or ammonium (NH3) solution were also studied to remove memory effect for ICPMS measurement. Although severe memory effect was observed on Milli-Q water dilution, NH3 solution could remove it successfully. The accuracy of the ID-ICPMS was validated by a certified reference material (CRM) as well as the comparison with the analytical result obtained by an instrumental neutron activation analysis (INAA) as different analytical method. From these results, the ID-ICPMS developed in the present study could be evaluated as accurate analytical method of Br in plastic materials and it could apply to certification of Br in candidate plastic CRM with respect to such regulations related to RoHS (restriction of the use of hazardous substances in electrical and electronics equipment) directive. (C) 2014 Elsevier B. V. All rights reserved.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 50 条
  • [21] DETERMINATION OF BARIUM IN MARINE WATERS BY ISOTOPE-DILUTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    KLINKHAMMER, GP
    CHAN, LH
    ANALYTICA CHIMICA ACTA, 1990, 232 (02) : 323 - 329
  • [22] Determination of hexavalent Cr in river sediments by speciated isotope dilution inductively coupled plasma mass spectrometry
    Drincic, Ana
    Zuliani, Tea
    Scancar, Janez
    Milacic, Radmila
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 637 : 1286 - 1294
  • [23] Isotopic homogenization of iridium for high sensitivity determination by isotope dilution inductively coupled plasma mass spectrometry
    Yi, YV
    Masuda, A
    ANALYTICAL SCIENCES, 1996, 12 (01) : 7 - 12
  • [24] Determination of cadmium and lead in urine by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry
    Lee, KH
    Liu, SH
    Jiang, SJ
    ANALYST, 1998, 123 (07) : 1557 - 1560
  • [25] Determination of Platinum Group Elements in Fall Dust by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry
    Zhu Yan
    Li Xiao-Lin
    Li Yu-Lan
    Gao Song
    Xu Qi
    Wang Zheng
    Tan Ming-Guang
    Li Yan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (05) : 695 - 699
  • [26] Determination of fetogram plutonium by extraction chromatography using isotope dilution inductively coupled plasma mass spectrometry
    Jin, YR
    Zhang, LZ
    Han, SJ
    Zhu, FR
    Bai, JF
    Zhou, GQ
    Ma, F
    Zhang, LX
    ACTA CHIMICA SINICA, 2000, 58 (10) : 1291 - 1295
  • [27] Validation protocol for the determination of copper in plant samples by isotope dilution inductively coupled plasma mass spectrometry
    Koplik, R
    Mestek, O
    Fingerová, H
    Suchánek, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (02) : 241 - 245
  • [28] Determination of mercury in biological and environmental samples by inductively coupled plasma mass spectrometry with the isotope dilution technique
    Yoshinaga, J
    Morita, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) : 417 - 420
  • [29] Determination of trace amount of lead in natural water by isotope dilution - Inductively coupled plasma mass spectrometry
    Department of Applied Chemistry, School of Engineering, Nagoya University, Chikusa-ku, Furo-cho, Nagoya 464-01, Japan
    Anal. Sci., 1600, SUPPL. (7-10):
  • [30] Determination of sulfur in fossil fuels by isotope dilution electrothermal vaporization inductively coupled plasma mass spectrometry
    Yu, LL
    Kelly, WR
    Fassett, JD
    Vocke, RD
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (02) : 140 - 145