Spectral Imaging of Iodine and Gadolinium Nanoparticles Using Dual-Energy CT

被引:5
|
作者
Badea, C. T. [1 ]
Holbrook, M. [1 ]
Clark, D. P. [1 ]
Ghaghada, K. [2 ]
机构
[1] Duke Univ, Dept Radiol, Ctr Vivo Microscopy, Durham, NC 27710 USA
[2] Texas Childrens Hosp, Singleton Dept Pediat Radiol, Houston, TX 77030 USA
关键词
micro-CT; preclinical; spectral; contrast agents; liposomes; nanoparticles; CONTRAST AGENT;
D O I
10.1117/12.2293625
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Advances in CT hardware have propelled the development of novel CT contrast agents. Combined with the spectral capabilities of X-ray CT, molecular imaging is possible using multiple heavy-metal contrast agents. Nanoparticle platforms make particularly attractive agents because of (1) their ability to carry a large payload of imaging moieties, and (2) their ease of surface modification to facilitate molecular targeting. While several novel imaging moieties based on high atomic number elements are being explored, iodine (I) and gadolinium (Gd) are particularly attractive because they are already in clinical use. In this work, we investigate the feasibility for in vivo discrimination of iodine and gadolinium nanoparticles using dual energy micro-CT. Phantom experiments were performed to measure the CT enhancement for I and Gd over a range of voltages from 40 to 80 kVp using a dual-source micro-CT system with energy integrating detectors having cesium iodide scintillators. The two voltages that provide maximum discrimination between I and Gd were determined to be 50 kVp with Cu filtration and 40 kVp without any filtration. Serial dilutions of I and Gd agents were imaged to determine detection sensitivity using the optimal acquisition parameters. Next, an in vivo longitudinal small animal study was performed using Liposomal I (Lip-I) and Liposomal Gd (Lip-Gd) nanoparticles. The mouse was intravenously administered Lip-Gd and imaged within 1 h post-contrast to visualize Gd in the vascular compartment. The animal was reimaged at 72 h post-contrast with dual-energy micro-CT at 40 kVp and 50 kVp to visualize the accumulation of Lip-Gd in the liver and spleen. Immediately thereafter, the animal was intravenously administered Lip-I and re-imaged. The dual energy sets were used to estimate the concentrations of Gd and I via a two-material decomposition with a non-negativity constraint. The phantom results indicated that the relative contrast enhancement per mg/ml of I to Gd was 0.85 at 40 kVp and 1.79 at 50 kVp. According to the Rose criterion (CNR>5), the detectability limits were 2.67 mg/ml for I and 2.46 mg/ml for Gd. The concentration maps confirmed the expected biodistribution, with Gd concentrated in the spleen and with I in the vasculature of the kidney, liver, and spleen. Iterative reconstruction provided higher sensitivity to detect relatively low concentrations of gadolinium. In conclusion, dual energy micro-CT can be used to discriminate and simultaneously image probes containing I and Gd.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Imaging Depiction of Hypoxic Pulmonary Vasoconstriction Using Dual-Energy CT
    Hunter, Joshua G.
    Prajapati, Priyanka
    Bera, Kaustav
    Gupta, Aekta
    Gupta, Amit
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [32] Advances of dual source, dual-energy imaging in postmortem CT
    Persson, Anders
    Jackowski, Christian
    Engstrom, Elias
    Zachrisson, Helene
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : 446 - 455
  • [33] Dual-energy CT in early acute pancreatitis: improved detection using iodine quantification
    Martin, Simon S.
    Trapp, Franziska
    Wichmann, Julian L.
    Albrecht, Moritz H.
    Lenga, Lukas
    Durden, James
    Booz, Christian
    Vogl, Thomas J.
    D'Angelo, Tommaso
    EUROPEAN RADIOLOGY, 2019, 29 (05) : 2226 - 2232
  • [34] Quantitative imaging of chemical composition using dual-energy, dual-source CT
    Liu, Xin
    Primak, Andrew N.
    Yu, Lifeng
    McCollough, Cynthia H.
    Morin, Richard L.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [35] Assessment of iodine uptake by pancreatic cancer following chemotherapy using dual-energy CT
    Satomi Kawamoto
    Matthew. K. Fuld
    Daniel Laheru
    Peng Huang
    Elliot K. Fishman
    Abdominal Radiology, 2018, 43 : 445 - 456
  • [36] Assessment of iodine uptake by pancreatic cancer following chemotherapy using dual-energy CT
    Kawamoto, Satomi
    Fuld, Matthew. K.
    Laheru, Daniel
    Huang, Peng
    Fishman, Elliot K.
    ABDOMINAL RADIOLOGY, 2018, 43 (02) : 445 - 456
  • [37] Dual-Energy (Spectral) Late Iodine Enhancement Cardiac CT: Does a Dual-Layer Detector Make It Work?
    Litt, Harold, I
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2019, 1 (01):
  • [38] Differentiation of osteolytic metastases and Schmorl's nodes in cancer patients using dual-energy CT: Advantage of spectral CT imaging
    Zheng, Shaowei
    Dong, Yue
    Miao, Yanwei
    Liu, Ailian
    Zhang, Xin
    Wang, Bin
    Ge, Ying
    Liu, Yijun
    Wang, Shaowu
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (07) : 1216 - 1221
  • [39] Dual-energy CT in early acute pancreatitis: improved detection using iodine quantification
    Simon S. Martin
    Franziska Trapp
    Julian L. Wichmann
    Moritz H. Albrecht
    Lukas Lenga
    James Durden
    Christian Booz
    Thomas J. Vogl
    Tommaso D’Angelo
    European Radiology, 2019, 29 : 2226 - 2232
  • [40] Dual-Energy CT Imaging in Diagnostic Imaging and Radiation Therapy
    Molloi, S.
    Li, B.
    Yin, F.
    Chen, H.
    MEDICAL PHYSICS, 2014, 41 (06) : 486 - 487