In vitro comparison of aortic valve movement after valve-preserving aortic replacement

被引:74
|
作者
Fries, Roland
Graeter, Thomas
Aicher, Diana
Reul, Helmut
Schmitz, Christoph
Boehm, Michael
Schaefers, Hans-Joachim
机构
[1] Univ Hosp Homburg, Dept Cardiol, Homburg, Germany
[2] Univ Hosp Homburg, Dept Thorac & Cardiovasc Surg, Homburg, Germany
[3] Univ Technol Aachen, Helmholtz Inst Biomed Engn, Aachen, Germany
来源
关键词
D O I
10.1016/j.jtcvs.2006.02.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: In aortic valve regurgitation and aortic dilatation, preservation of the aortic valve is possible by means of root remodeling ( Yacoub procedure) or valve reimplantation ( David procedure). In vivo studies suggest that reimplantation might substantially influence aortic valve-motion characteristics. Evaluation of aortic valve movement in vivo, however, is technically limited and is difficult to standardize. We evaluated the aortic valve-motion pattern echocardiographically in vitro after reimplantation and remodeling. Methods: By using aortic roots of house pigs ( aortoventricular diameter, 22 mm) a Yacoub procedure ( 22-mm graft; Yacoub, n = 5) or a David I procedure ( 24-mm graft; David, n = 5) was performed. Roots after supracommissural replacement ( 22-mm graft; Supra, n = 5) served as control valves. In an electrohydraulic, computer-controlled pulse duplicator the valves were tested at flows of 2, 4, 7, and 9 L/min. Echocardiographically assessed parameters were rapid valve-opening velocity, slow valve-closing velocity, rapid valve-closing velocity, rapid valve-opening time, rapid valve-closing time, ejection time, maximum valve opening, slow valve-closing displacement, and maximum flow velocity. Results: Mean rapid valve-opening velocity and mean rapid valve-closing velocity at a cardiac output of 2 to 9 L/min were fastest in David ( rapid valve-opening velocity: 69 +/- 10 cm/s [ David] vs 39 +/- 4 cm/s [ Yacoub] vs 42 +/- 4 cm/ s [ Supra], P = .0041; rapid valve-closing velocity: 22 +/- 2 cm/s [ David] vs 16 +/- 2 cm/s [ Yacoub] vs 17 +/- 1 cm/s [ Supra], P = .0272), and slow valve-closing velocity was slowest in David ( 0.2 +/- 0.1 cm/s [ David] vs 1.0 +/- 0.3 cm/s [ Yacoub] vs 0.6 +/- 0.1 cm/s [ Supra], P = .0063). With increasing cardiac output, the difference in rapid valve-opening velocity between the groups increased, the difference in slow valve-closing velocity remained unchanged, and the difference in rapid valve-closing velocity decreased. Conclusions: In this standardized experimental setting remodeling of the aortic valve provides significantly smoother valve movements. This might contribute to preservation of a better valve performance during long-term follow-up.
引用
收藏
页码:32 / 37
页数:6
相关论文
共 50 条
  • [31] Predictors of aortic events after aortic valve replacement for bicuspid valve stenosis
    Dayan, Victor
    Pizzano, Nelson
    Cura, Leandro
    Ferreiro, Alejandro
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 44 (02) : 398 - 398
  • [32] Persistent Native Aortic Valve Function after Transcatheter Aortic Valve Replacement
    Singh, Vikas
    Martinez, Claudia A.
    O'Neill, William W.
    Heldman, Alan W.
    TEXAS HEART INSTITUTE JOURNAL, 2013, 40 (03) : 364 - 366
  • [33] Anterior motion of the mitral valve after aortic valve replacement for aortic insufficiency
    Mikhail, R. Sukernik
    Andrew, D. Sumner
    Pae, Walter E.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (04) : 574 - 576
  • [34] Midterm results after aortic valve replacement with a stentless bioprosthesis aortic valve
    Martinovic, I
    Everlien, M
    Farah, I
    Wittlinger, T
    Knez, I
    Greve, H
    Vogt, P
    ANNALS OF THORACIC SURGERY, 2005, 80 (01): : 198 - 203
  • [35] Outcomes of Surgical Aortic Valve Replacement After Transcatheter Aortic Valve Implantation
    Ogami, Takuya
    Ridgley, Jacqueline
    Serna-Gallegos, Derek
    Kliner, Dustin E.
    Toma, Catalin
    Sanon, Saurabh
    Brown, James A.
    Yousef, Sarah
    Sultan, Ibrahim
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 182 : 63 - 68
  • [36] Later aorta operation after aortic valve replacement for bicuspid aortic valve
    Kohei Hachiro
    Noriyuki Takashima
    Tomoaki Suzuki
    Journal of Cardiothoracic Surgery, 19
  • [37] Redo Surgical Aortic Valve Replacement versus Valve in Valve Transcatheter Aortic Valve Replacement
    Patel, Parth M.
    Chiou, Edward
    Wei, Jane W.
    Binongo, Jose N.
    Guyton, Robert A.
    Leshnower, Bradley G.
    Grubb, Kendra J.
    Chen, Edward P.
    CIRCULATION, 2020, 142
  • [38] Surgical Aortic Valve Replacement after Transcatheter Aortic Valve Replacement: A Single Center Experience
    Hocking, Jennie A.
    Eisenga, John
    Mccullough, Kyle
    Moubarak, Ghadi
    Kluis, Austin
    Harrington, Katherine B.
    Schaffer, Justin M.
    Dimaio, J.
    George, Timothy J.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2024, 239 (05) : S75 - S75
  • [39] Progressive aortic dilation after aortic valve replacement
    Yuan, Shi-Min
    Lavee, Jacob
    SURGICAL PRACTICE, 2012, 16 (04) : 137 - 141
  • [40] Acute aortic dissection after aortic valve replacement
    Kohata S.
    Sugama M.
    Ogata T.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 1998, 46 (1): : 101 - 104