STUDY ON THERMAL INSULATION AND HEAT TRANSFER PROPERTIES OF WOOD FRAME WALLS

被引:0
|
作者
Liu, Mingbin [1 ]
Sun, Youfu [1 ]
Sun, Chen [1 ]
Yang, Xiaolin [2 ]
机构
[1] Nanjing Forestry Univ, Coll Mat Sci & Engn, Nanjing 210037, Jiangsu, Peoples R China
[2] Zhengzhou Univ, Sch Architecture, Zhengzhou 450001, Henan, Peoples R China
关键词
Wood frame wall; insulation; heat transfer coefficient; thermal resistance; OPTIMIZATION; BUILDINGS; AIR;
D O I
暂无
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
Steady-state heat transfer performance of wood frame wall is an important index to assess its energy efficiency. In order to study the factors that affect the heat transfer coefficient of wood frame wall, the method of improving the thermal insulation property of the wall was studied. In this paper, 12 wall specimens with different structures were manufactured, and the effective heat transfer coefficient was measured by the hot box-heat flow meter test method. The reliability of the theoretical calculation value of thermal resistance was verified by the experimental value. The results showed that the moisture content of Spruce-pine-fir (SPF), insulation materials, spacing and thickness of studs had influence on the heat transfer coefficient of walls. The effective heat transfer coefficient values of three walls ranged from 0.325 to 0.398 W.m(-2) .K-1, which met the thermal level It of the severe cold area. The linear correlation between the theoretical calculation value and the test value was up to 0.9587, effective thermal resistance value of wood frame wall can be estimated by calculating without extra experiment.
引用
收藏
页码:249 / 260
页数:12
相关论文
共 50 条
  • [41] Advances in modelling heat transfer through wood framed walls in fire
    Clancy, P
    FIRE AND MATERIALS, 2001, 25 (06) : 241 - 254
  • [42] Study on temperature effects on walls with thermal insulation mortar system
    Qin, Shang-Song
    Liu, Yuan-Zhen
    Li, Zhu
    Wang, Hong
    Gongcheng Lixue/Engineering Mechanics, 2011, 28 (SUPPL. 1): : 64 - 68
  • [43] Active thermal insulation as an element limiting heat loss through external walls
    Kisilewicz, Tomasz
    Fedorczak-Cisak, Malgorzata
    Barkanyi, Tamas
    ENERGY AND BUILDINGS, 2019, 205
  • [44] Comparative thermal analyis of structural insulated panels and wood frame walls for residential buildings
    Krarti, Moncef
    Hildreth, Tom
    Proceedings of the ASME International Solar Energy Conference, 2007, : 659 - 669
  • [45] Effect of the placement of aerogel insulation in the heat transfer properties
    Lakatos, Akos
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2018, 133 (01) : 321 - 327
  • [46] Effect of the placement of aerogel insulation in the heat transfer properties
    Ákos Lakatos
    Journal of Thermal Analysis and Calorimetry, 2018, 133 : 321 - 327
  • [47] EVALUATION OF THERMAL PROPERTIES OF WOOD BASED COMPOSITE PANEL WALLS
    Rozins, Rihards
    Iejavs, Janis
    RESEARCH FOR RURAL DEVELOPMENT 2014, VOL 2, 2014, : 109 - 114
  • [48] Glove thermal insulation: local heat transfer measures and relevance
    Hayet Sari
    Maurice Gartner
    Alain Hoeft
    Victor Candas
    European Journal of Applied Physiology, 2004, 92 : 702 - 705
  • [49] Thermal insulation with PCM. Mathematical model for heat transfer
    Pavel, PM
    Constantinescu, M
    Chilom, O
    REVUE ROUMAINE DE CHIMIE, 1997, 42 (02) : 153 - 158
  • [50] Glove thermal insulation: local heat transfer measures and relevance
    Sari, H
    Gartner, M
    Hoeft, A
    Candas, V
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 92 (06) : 702 - 705