Inductively coupled plasma mass spectrometry for direct multi-element analysis of diluted human blood and serum

被引:158
|
作者
Barany, E
Bergdahl, IA
Schutz, A
Skerfving, S
Oskarsson, A
机构
[1] LUND UNIV,DEPT OCCUPAT & ENVIRONM MED,S-22185 LUND,SWEDEN
[2] SWEDISH UNIV AGR SCI,DEPT FOOD HYG,S-75007 UPPSALA,SWEDEN
关键词
inductively coupled plasma mass spectrometry; blood; serum; blood plasma; multi-element; flow injection;
D O I
10.1039/a700904f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the inductively coupled plasma mass spectrometry (ICP-MS) multi-element analysis of diluted human blood and serum was used for the following elements: Co, Ni, Cu, Zn, Ga, Se, Rb, Mo, Ph, Pd, Cd, Sn, Sb, W, Pt, Hg, Tl and Pb. Sample pretreatment was a simple dilution (ten times for blood and five times for serum) with a solution containing 5 g l(-1) of 25% ammonia, 0.5 g l(-1) Triton X-100, and 0.5 g l(-1) EDTA in Millipore water. In and Sc were used as internal standards. For sample introduction a flow-injection-type technique (based on time instead of volume) was used. The determinations mere carried out first in a peak-jumping mode for selected masses, and then in a scanning mode. Each determination of a preparation took 75 s. The results for reference samples agreed with recommended or certified values for Co, Cu, Zn, Rb, Cd, Tl and Pb in blood, and for Rb, Mo and Cd in serum. For Ni and Hg in blood, and Cu and Zn in serum, the results agreed with one of two reference samples. The detection limits for all these elements (except for Tl) were sufficient for analysis of samples from the general population. On the other hand, the results for Se in blood, and for Co, Ni, Se, Sn and Hg in serum did not agree with recommended or certified values. No reference samples are available for Ga, Mo, Ph, Pd, Sn, Sb, W, or Pt in blood, or for Ga, Ph, Pd, W, Pt, or Pb in serum. Generally, the limits of detection for the elements in the latter group (below 0.15 mu g l(-1)) are close to or above the levels present in the general population.
引用
收藏
页码:1005 / 1009
页数:5
相关论文
共 50 条
  • [31] APPLICATION OF INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROSCOPY FOR MULTI-ELEMENT ANALYSIS OF SERUM AND URINE
    SUDDENDORF, RF
    SMITH, GL
    CLINICAL CHEMISTRY, 1981, 27 (06) : 1095 - 1095
  • [32] Validation of inductively coupled plasma atomic emission spectrometry technique (ICP-AES) for multi-element analysis of trace elements in human serum
    Rahil-Khazen, R
    Henriksen, H
    Bolann, BJ
    Ulvik, RJ
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2000, 60 (08): : 677 - 686
  • [33] Multi-element analysis of spices by inductively coupled plasma mass spectrometry and human risk assessment in the Rabat-Sale-Temara area (Morocco)
    El Youssfi, Mourad
    Flayou, Majda
    El Idrissi, Zineb Lakhlifi
    Ben Ali, Majda
    Bennani, Mohamed
    El Hamidi, Adnane
    Ben Aakame, Rachid
    Laghzizil, Abdelaziz
    Zinedine, Abdellah
    Sifou, Aicha
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2025, 140
  • [34] Flow injection on-line dilution for multi-element determination in human urine with detection by inductively coupled plasma mass spectrometry
    Wang, JH
    Hansen, EH
    Gammelgaard, B
    TALANTA, 2001, 55 (01) : 117 - 126
  • [35] Multi-element determination in complex matrices by inductively coupled plasma-mass spectrometry (ICP-MS)
    Holmes, LJ
    Robinson, VJ
    Makinson, PR
    Livens, FR
    SCIENCE OF THE TOTAL ENVIRONMENT, 1995, 173 (1-6) : 345 - 350
  • [36] Examination on simultaneous multi-element isotope ratio measurement by inductively coupled plasma time of flight mass spectrometry
    Ohata, Masaki
    Hagino, Hiroyuki
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2018, 430 : 31 - 36
  • [38] Method validation for a multi-element panel in human seminal plasma by inductively coupled plasma tandem mass spectrometry (ICP-MS/MS)
    Navratilova, J.
    Myskova, M.
    Kuta, J.
    Franzova, K.
    Jeseta, M.
    HUMAN REPRODUCTION, 2022, 37 : 207 - 208
  • [39] MULTI-ELEMENT ANALYSIS OF AIRBORNE PARTICULATE MATTER BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
    WANG, CF
    MIAU, TT
    PERNG, JY
    YEH, SJ
    CHIANG, PC
    TSAI, HT
    YANG, MH
    ANALYST, 1989, 114 (09) : 1067 - 1070
  • [40] Multi-element analysis of food by microwave digestion and inductively coupled plasma-atomic emission spectrometry
    Dolan, SP
    Capar, SG
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2002, 15 (05) : 593 - 615