Development of a Traceable Fire Alarm System Based on the Conventional Fire Alarm System

被引:13
|
作者
Jee, Seung-Wook [1 ]
Lee, Chun-Ha [1 ]
Kim, Si-Kuk [1 ]
Lee, Jae-Jin [2 ]
Kim, Phil-Young [2 ]
机构
[1] Hoseo Univ, Dept Fire & Disaster Protect Engn, Asan, Chungcheongnam, South Korea
[2] TST Co, Gunpo Si, Gyeonggi Do, South Korea
关键词
Fire alarm system; Fire alarm control panel; Heat detector; Conventional fire alarm system; Traceable fire alarm system;
D O I
10.1007/s10694-012-0299-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Many countries use conventional fire alarm control panels (FACPs) and conventional detectors as fire alarm systems (FASs) because of economic advantages. This study analyzes several problems with conventional FASs and describes an advanced FAS, the traceable FAS, that we developed to solve these problems. The traceable FAS can trace the exact location of a fire, can detect multiple fires that occur simultaneously, and can be used with conventional detectors without disrupting the other detectors operation. The traceable FAS consists of a traceable FACP based on the conventional FACP and a traceable heat detector based on the rate-of-rise spot-type conventional heat detector. The new system offers traceability in addition to all the features of the conventional FAS. The traceable FACP has 40 zones; one zone can connect up to 20 traceable heat detectors. Thus, this FACP can connect up to 800 traceable heat detectors, all of which can detect and trace exact fire locations in sequence. Furthermore, the traceable FACP can be used with both traceable heat detectors and conventional heat detectors in the same zone. Even if one detector (either traceable heat detector or conventional heat detector) detects a fire first, other traceable heat detectors in the same zone can also detect it and display the results on the traceable FACP. Prototypes of the traceable FACP and traceable heat detector (rate-of-rise spot-type) have officially received model approvals for use in South Korea. Conventional FASs can be upgraded to traceable FASs simply by changing to the traceable FACP and traceable heat detectors, without any rewiring.
引用
收藏
页码:805 / 822
页数:18
相关论文
共 50 条
  • [21] Intelligent fire alarm system from Norway
    不详
    NAVAL ARCHITECT, 1999, : 15 - 15
  • [22] Smart Fire-Alarm System for Home
    Kang, Jihoon
    Basnet, Shreya
    Farhad, Sardar M.
    COMPLEX, INTELLIGENT, AND SOFTWARE INTENSIVE SYSTEMS (CISIS 2019), 2020, 993 : 474 - 483
  • [23] Performance characteristics and assessment of fire alarm system
    Gupta, Surbhi
    Kanwar, Shefali
    Kashyap, Manju
    MATERIALS TODAY-PROCEEDINGS, 2022, 57 : 2036 - 2040
  • [24] Research of Fire Alarm System Based on RFID and Temperature Sensors
    Wu Linli
    Xu Hongsheng
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 5203 - 5207
  • [25] Research and design of GSM-based fire alarm system
    Mao, L
    Duan, QC
    Proceedings of the 11th Joint International Computer Conference, 2005, : 308 - 311
  • [26] The Research of Forest Fire Alarm System based on Video Monitoring
    Guan, Hongyun
    Gong, Chuming
    PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON MECHANICAL, ELECTRONIC, CONTROL AND AUTOMATION ENGINEERING (MECAE 2017), 2017, 61 : 139 - 142
  • [27] Design and Realization of Fire Alarm System Based on CAN Bus
    Chen Yneping
    Gan Fangcheng
    Zhang Yongxian
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL I, 2007, : 832 - 836
  • [28] A ship fire alarm system based on fuzzy neural network
    Wang, XH
    Xiao, JM
    Bao, MZ
    PROCEEDINGS OF THE 3RD WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-5, 2000, : 1734 - 1736
  • [29] FIRE ALARM
    SCANLON, TW
    AMERICAN BAR ASSOCIATION JOURNAL, 1983, 69 (AUG): : 1006 - 1006
  • [30] Fire Alarm
    Slavcheff, Mary Ann DeNeve
    AMERICAN HISTORY, 2015, 50 (05) : 4 - 4