Development of a Traceable Fire Alarm System Based on the Conventional Fire Alarm System

被引:13
|
作者
Jee, Seung-Wook [1 ]
Lee, Chun-Ha [1 ]
Kim, Si-Kuk [1 ]
Lee, Jae-Jin [2 ]
Kim, Phil-Young [2 ]
机构
[1] Hoseo Univ, Dept Fire & Disaster Protect Engn, Asan, Chungcheongnam, South Korea
[2] TST Co, Gunpo Si, Gyeonggi Do, South Korea
关键词
Fire alarm system; Fire alarm control panel; Heat detector; Conventional fire alarm system; Traceable fire alarm system;
D O I
10.1007/s10694-012-0299-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Many countries use conventional fire alarm control panels (FACPs) and conventional detectors as fire alarm systems (FASs) because of economic advantages. This study analyzes several problems with conventional FASs and describes an advanced FAS, the traceable FAS, that we developed to solve these problems. The traceable FAS can trace the exact location of a fire, can detect multiple fires that occur simultaneously, and can be used with conventional detectors without disrupting the other detectors operation. The traceable FAS consists of a traceable FACP based on the conventional FACP and a traceable heat detector based on the rate-of-rise spot-type conventional heat detector. The new system offers traceability in addition to all the features of the conventional FAS. The traceable FACP has 40 zones; one zone can connect up to 20 traceable heat detectors. Thus, this FACP can connect up to 800 traceable heat detectors, all of which can detect and trace exact fire locations in sequence. Furthermore, the traceable FACP can be used with both traceable heat detectors and conventional heat detectors in the same zone. Even if one detector (either traceable heat detector or conventional heat detector) detects a fire first, other traceable heat detectors in the same zone can also detect it and display the results on the traceable FACP. Prototypes of the traceable FACP and traceable heat detector (rate-of-rise spot-type) have officially received model approvals for use in South Korea. Conventional FASs can be upgraded to traceable FASs simply by changing to the traceable FACP and traceable heat detectors, without any rewiring.
引用
收藏
页码:805 / 822
页数:18
相关论文
共 50 条
  • [1] Development of a Traceable Fire Alarm System Based on the Conventional Fire Alarm System
    Seung-Wook Jee
    Chun-Ha Lee
    Si-Kuk Kim
    Jae-Jin Lee
    Phil-Young Kim
    Fire Technology, 2014, 50 : 805 - 822
  • [2] Design of a Fire alarm system
    Cheng, Yuhui
    Zhang, Tianyi
    PROCEEDINGS OF THE 2021 INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS (ICAROB 2021), 2021, : P64 - P64
  • [3] Fire alarm system facts
    EC M Electr Constr Maint, 2006, 11 (40-44):
  • [4] The gamewell fire alarm system
    Emms, Mervyn
    Elektron, 2003, 20 (04): : 14 - 15
  • [5] Design of a Fire alarm system
    Cheng, Yuhui
    Zhang, Tianyi
    PROCEEDINGS OF THE 2021 INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS (ICAROB 2021), 2021, : 671 - 675
  • [6] Alarm research in fire alarm system based on digital temperature sensor alarm search
    Hong, Ai
    Jie, Wang
    Li, Zheng-Xi
    Wan, Ming-Ming
    WAVELET ACTIVE MEDIA TECHNOLOGY AND INFORMATION PROCESSING, VOL 1 AND 2, 2006, : 156 - +
  • [7] FIRE ALARM SYSTEM RELIABILITY.
    Solomon, E.E.
    Consulting-Specifying Engineer, 1987, 1 (05) : 61 - 65
  • [8] Reliability Analysis of a Fire Alarm System
    Chen, Yanghou
    INTERNATIONAL CONFERENCE ON ADVANCES IN ENGINEERING 2011, 2011, 24 : 731 - 736
  • [9] The fire alarm system in the United States
    不详
    NATURE, 1940, 146 : 408 - 408
  • [10] An Intelligent Fire Alarm System Based on GSM Network
    Wang, Yue-jiao
    Ren, Xiao-kui
    COMMUNICATIONS AND INFORMATION PROCESSING, PT 2, 2012, 289 : 232 - +