Reduction of gradient acoustic noise in MRI using SENSE-EPI

被引:48
|
作者
de Zwart, JA
van Gelderen, P
Kellman, P
Duyn, JH
机构
[1] NINDS, Lab Funct & Mol Imaging, NIH, Bethesda, MD 20892 USA
[2] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
关键词
D O I
10.1006/nimg.2002.1119
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A new approach to reduce gradient acoustic noise levels in EPI experiments is presented. Using multichannel RF receive coils, combined. With SENSE data Acquisition and reconstruction, gradient slew-rates in single-shot EPI were reduced fourfold for rate-2 and ninefold for rate-3 SENSE. Multislice EPI experiments Were performed on three different scanner platforms. With 3.4 min in-plane resolution, measuring 6 slices per second (1 slices with 2000 ms TR), this resulted in average sound pressure level reductions of 11.3 dB(A) and 16.5 dB(A) for rate-2 and rate-3 SENSE, respectively. BOLD fMRI experiments, using visually paced finger-tapping paradigms, showed no detrimental effect of the acoustic noise reduction strategy con temporal noise levels and t scores.
引用
收藏
页码:1151 / 1155
页数:5
相关论文
共 50 条
  • [31] Active-passive shielding for MRI acoustic noise reduction: Network analysis
    Kidane, Tesfaye K.
    Edelstein, William A.
    Eagan, Timothy P.
    Taracila, Victor
    Baig, Tanvir N.
    Cheng, Yu-Chung N.
    Brown, Robert W.
    IEEE TRANSACTIONS ON MAGNETICS, 2006, 42 (12) : 3854 - 3860
  • [32] Reduction of MRI acoustic noise achieved by manipulation of scan parameters e A study using veterinary MR sequences
    Baker, Martin A.
    RADIOGRAPHY, 2013, 19 (01) : 11 - 16
  • [33] NOISE REDUCTION BY GRADIENT DESCENT
    Davies, Mike
    INTERNATIONAL JOURNAL OF BIFURCATION AND CHAOS, 1993, 3 (01): : 113 - 118
  • [34] Functional MRI of the motor cortex using a conventional gradient system:: Comparison of FLASH and EPI techniques
    Fellner, C
    Schlaier, J
    Müller, E
    Fellner, F
    MAGNETIC RESONANCE IMAGING, 1998, 16 (10) : 1171 - 1180
  • [35] Modal analysis and acoustic noise characterization of a 4T MRI gradient coil insert
    Mechefske, CK
    Yao, G
    Li, W
    Gazdzinski, C
    Rutt, BK
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2004, 22B (01) : 37 - 49
  • [36] Noise estimation in parallel MRI: GRAPPA and SENSE
    Aja-Fernandez, Santiago
    Vegas-Sanchez-Ferrero, Gonzalo
    Tristan-Vega, Antonio
    MAGNETIC RESONANCE IMAGING, 2014, 32 (03) : 281 - 290
  • [37] MRI scanner vibration and acoustic noise
    Mechefske, Chris K.
    Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, Vol 1, Pts A-C, 2005, : 2575 - 2585
  • [38] Optimized gradient pulse for use with EPI employing active acoustic control
    Chapman, BLW
    Haywood, B
    Mansfield, P
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 931 - 935
  • [39] Evaluation of magnetic resonance imaging acoustic noise reduction technology by magnetic gradient waveform control
    Yamashiro, Takanobu
    Morita, Kosuke
    Nakajima, Kazuhiro
    MAGNETIC RESONANCE IMAGING, 2019, 63 : 170 - 177
  • [40] Active acoustic control in gradient coils for MRI
    Mansfield, P
    Haywood, B
    Coxon, R
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) : 807 - 818