摘要
Objective: Cerebellar diseases frequently affect the ocular motor neural velocity-to-position integrator by increasing its leakiness and thereby causing gaze-evoked nystagmus (GEN) and rebound nystagmus (RN). Minor leakiness is physiological and occasionally causes GEN in healthy humans. We aimed to evaluate the characteristics of GEN/RN in healthy subjects for better differentiation between physiological and pathological GEN/RN. Methods: Using video-oculography, eye position was measured in 14 healthy humans at straight ahead eye position before and after, and during 30 s of ocular fixation at 4 horizontal eccentric targets between 30 degrees and 45 degrees. We determined the eye drift velocity and the prevalence of nystagmus before/during/after eccentric fixation. Results: Eye drift velocities during (range: 0.62 +/- 0.53 degrees/s to 1.78 +/- 0.69 degrees/s) and after eccentric gaze (range: 0.28 +/- 0.52 degrees/s to 1.48 +/- 1.02 degrees/s) increased with the amount of gaze eccentricity (30 degrees-45 degrees). During continuous eccentric gaze, eye drift velocities decreased by 0.41 +/- 0.18 degrees/s at 30 degrees, and 0.84 +/- 0.38 degrees/s at 45 degrees gaze eccentricity. GEN was elicited in 71% of subjects at 30 degrees gaze eccentricity. Twenty-one percent showed RN thereafter. This prevalence increased to 100% (GEN)/72% (RN) at 45 degrees gaze eccentricity. RN found after 30 degrees gaze eccentricity was of low velocity (0.82 +/- 0.21 degrees/s) and occurred after minor drift velocity decrease during prior eccentric gaze (0.43 +/- 0.15 degrees/s). Conclusion: GEN and RN should be tested using horizontal gaze eccentricities of <30 degrees, since most healthy subjects physiologically show GEN and RN at higher eccentricities. In case of an uncertain result, both the reduction of eye drift velocity during eccentric gaze and the velocity of RN can be analyzed to distinguish physiological from pathological nystagmus.
引用
收藏
页数:6
相关论文
共 41 条
  • [41] Positional End-Point Nystagmus during Positional Testing: Prevalence, Characteristics and Differences with Benign Paroxysmal Positional Vertigo
    Dominguez-Duran, Emilio
    Prieto-Sanchez-de-Puerta, Lucia
    Ivan Martin-Jimenez, Daniel
    Sanchez-Gomez, Serafin
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (01)