Compressive properties of mouse articular cartilage determined in a novel micro-indentation test method and biphasic finite element model

被引:73
|
作者
Cao, Li
Youn, Inchan
Guilak, Farshid
Setton, Lori A.
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Duke Univ, Med Ctr, Dept Surg, Div Orthopaed Surg, Durham, NC 27710 USA
关键词
mechanical properties; indentation; compression; cartilage; biphasic; finite element model; optimization; genetic algorithm; mouse; osteoarthritis;
D O I
10.1115/1.2246237
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The mechanical Properties of articular cartilage serve as important measures of tissue function or degeneration, and are known to change significantly with osteoarthritis. Interest in small animal and mouse models of osteoarthritis has increased as studies reveal the importance of genetic background in determining predisposition to osteoarthritis. While indentation testing provides a method of determining cartilage mechanical properties in situ, it has been of limited value in studying mouse joints due to the relatively small size of the joint and thickness of the cartilage layer In this study, we developed a micro-indentation testing system to determine the compressive and biphasic mechanical properties of cartilage in the small joints of the mouse. A nonlinear optimization program employing a genetic algorithm for parameter estimation, combined with a biphasic finite element model of the micro-indentation test, was developed to obtain the biphasic, compressive material properties of articular cartilage. The creep response and material properties of lateral tibial plateau cartilage were obtained for wild-type mouse knee joints, by the micro-indentation testing and optimization algorithm. The newly developed genetic algorithm was found to be efficient and accurate when used with the finite element simulations for nonlinear optimization to the experimental creep data. The biphasic mechanical properties of mouse cartilage in compression (average values: Young's modulus, 2.0 MPa; Poisson's ratio, 0.20; and hydraulic permeability, 1.1 X 10(-16) m(4) /N-s) were found to be of similar orders of magnitude as previous findings for other animal cartilages, including human, bovine, rat, and rabbit and demonstrate the utility of the new test methods. This study provides the first available data for biphasic compressive properties in mouse cartilage and suggests a promising method for detecting altered cartilage mechanics in small animal models of osteoarthritis.
引用
收藏
页码:766 / 771
页数:6
相关论文
共 25 条
  • [21] Study of the Mechanical Properties of NiTi Modified by Carbon Plasma Immersion Ion Implantation Using Nano-Indentation Test and Finite Element Method Simulation
    Shanaghi, A.
    Siyavoshi, A.
    Souri, A. R.
    Shanaghi, Ab
    Chu, P. K.
    PHYSICS OF METALS AND METALLOGRAPHY, 2022, 123 (13): : 1395 - 1401
  • [22] Study of the Mechanical Properties of NiTi Modified by Carbon Plasma Immersion Ion Implantation Using Nano-Indentation Test and Finite Element Method Simulation
    A. Shanaghi
    A. Siyavoshi
    A. R. Souri
    Ab. Shanaghi
    P. K. Chu
    Physics of Metals and Metallography, 2022, 123 : 1395 - 1401
  • [23] A Novel Method to Correlate a Rocket Launcher Finite Element Model Using Experimental Modal Test Measurements and Identification Algorithms
    Couch, Ronald N.
    Radcliffe, Eliott J.
    Caldwell, Rickey A.
    SHOCK & VIBRATION, AIRCRAFT/AEROSPACE, ENERGY HARVESTING, ACOUSTICS & OPTICS, VOL 9, 2016, : 153 - 166
  • [24] Pore effect on macroscopic physical properties: Composite elasticity determined using a two-dimensional buffer layer finite element method model
    Yoneda, Akira
    Sohag, Ferdous Hasan
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2011, 116
  • [25] A novel method for assigning bone material properties to a comprehensive patient-specific pelvic finite element model using biplanar multi-energy radiographs
    Qiao, Ningxin
    Villemure, Isabelle
    Aubin, Carl-Eric
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (16) : 2377 - 2388