Nozzle Track and CHF Prediction of Spray Cooling for Inclined Sprays

被引:1
|
作者
Guo, Yong-xian [1 ]
Jia, Jian-yuan [1 ]
Chang, Jian-tao [1 ]
Liu, Huan-ling [1 ]
Zhou, Shao-rong [2 ]
机构
[1] Xidian Univ, Sch Mechanoelect Engn, Xian 710071, Shaanxi, Peoples R China
[2] Intel Asia Pacific Res & Dev Ltd, Shanghai, Peoples R China
关键词
Spray cooling; Inclination; CHF; circular nozzle; foursquare nozzle; CRITICAL HEAT-FLUX; SINGLE-NOZZLE; SURFACE; ARRAYS;
D O I
10.1109/STHERM.2009.4810764
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The tracks of the nozzles were studied during spray cooling with different inclination angles, based on the study of Visaria and the critical heat flux (CHF) criterion, which means that CHF will be achieved when the spray is configured on the condition that the spray impact area just inscribes a square test surface. The predictions of the tracks of the nozzles were made. It indicates that the nozzle tracks are parts of some ellipses as keeping the four borderline of the square test surface being the tangent line of the elliptical spray impact area. A new CHF model was established and new expression of CHF was derived based on the nozzle track model and the study of Visaria. The effects of spray inclination angle on CHIF were predicted. Simulation results indicate that CHF increases slightly with increasing inclination angle. The maximum difference of CHF of the three nozzles been simulated is about 13.1%. One reason for the difference between the established model and the results derived by Visaria is attributed to the difference of the spray impact area. The tracks of circular nozzles spraying onto a circular surface with inclination angles were discussed, and it shows that the tracks are parts of some circles. The tracks of foursquare nozzles spraying onto circular surface and foursquare surface were also discussed, and it shows that the tracks are parts of some circles. As a certain inclination angle and the same cone angle, foursquare nozzles have the largest impact area while there is a foursquare heated surface.
引用
收藏
页码:201 / +
页数:2
相关论文
共 50 条
  • [21] Cooling performance of multi-nozzle spray with liquid nitrogen
    Xue, Rong
    Lin, Xinyi
    Ruan, Yixiao
    Chen, Liang
    Hou, Yu
    CRYOGENICS, 2022, 121
  • [22] Nozzle less spray cooling using surface acoustic waves
    Ang, Kar M.
    Yeo, Leslie Y.
    Friend, James R.
    Hung, Yew M.
    Tan, Ming K.
    JOURNAL OF AEROSOL SCIENCE, 2015, 79 : 48 - 60
  • [23] Influence of the Nozzle-to-Surface Distance on Spray Cooling Efficiency
    Vladyko, Ilya
    Miskiv, Nikolay
    Serdyukov, Vladimir
    Nazarov, Aleksandr
    Surtaev, Anton
    FLUIDS, 2023, 8 (07)
  • [24] Experimental Study on Spray Cooling Performance of Pressure Atomizing Nozzle
    黄晓庆
    张旭
    Transactions of Tianjin University, 2012, 18 (03) : 231 - 235
  • [25] Experimental Study on Spray Cooling Performance of Pressure Atomizing Nozzle
    黄晓庆
    张旭
    Transactions of Tianjin University, 2012, (03) : 231 - 235
  • [26] Critical heat flux of multi-nozzle spray cooling
    Lin, LC
    Ponnappan, R
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2004, 126 (03): : 482 - 485
  • [27] EMAT Detection Method of Spray Cooling Characteristics for Industrial Nozzle
    Ouyang, Qi
    Zeng, Yue Bing
    Zhang, Xinglan
    Chen, Xi Meng
    26TH CHINESE CONTROL AND DECISION CONFERENCE (2014 CCDC), 2014, : 3279 - 3284
  • [28] Effects of nozzle positioning on single-phase spray cooling
    Gao, Xuan
    Li, Ri
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 115 : 1247 - 1257
  • [29] Experimental study on spray cooling performance of pressure atomizing nozzle
    Huang, Xiaoqing
    Zhang, Xu
    Huang, X. (hxq-101@163.com), 2012, Tianjin University (18): : 231 - 235
  • [30] Numerical simulation and analysis of multi-nozzle spray cooling
    Tao, Y.-J. (tyj@iet.cn), 1600, Science Press (33):