A comparative assessment of small-head metal-on-metal and ceramic-on-polyethylene total hip replacement

被引:8
|
作者
Luebbeke, A. [1 ]
Gonzalez, A. [1 ]
Garavaglia, G. [1 ]
Roussos, C. [1 ]
Bonvin, A. [1 ]
Stern, R. [1 ]
Peter, R. [1 ]
Hoffmeyer, P. [1 ]
机构
[1] Univ Hosp Geneva, CH-1211 Geneva, Switzerland
来源
BONE & JOINT JOURNAL | 2014年 / 96B卷 / 07期
关键词
10-YEAR FOLLOW-UP; BEARING SURFACES; FAILURE RATES; ARTHROPLASTY; WEAR; CUP; SURVIVORSHIP; ARTICULATION; DISLOCATION; COMPONENT;
D O I
10.1302/0301-620X.96B7.32369
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Large-head metal-on-metal (MoM) total hip replacements (THR) have given rise to concern. Comparative studies of small-head MoM THRs over a longer follow-up period are lacking. Our objective was to compare the incidence of complications such as infection, dislocation, revision, adverse local tissue reactions, mortality and radiological and clinical outcomes in small-head (28 mm) MoM and ceramic-on-polyethylene (CoP) THRs up to 12 years post-operatively. A prospective cohort study included 3341 THRs in 2714 patients. The mean age was 69.1 years (range 24 to 98) and 1848 (55.3%) were performed in women, with a mean follow-up of 115 months (18 to 201). There were 883 MoM and 2458 CoP bearings. Crude incidence rates (cases/1000 person-years) were: infection 1.3 vs 0.8; dislocation 3.3 vs 3.1 and all-cause revision 4.3 vs 2.2, respectively. There was a significantly higher revision rate after ten years (adjusted hazard ratio 9.4; 95% CI 2.6 to 33.6) in the MoM group, and ten of 26 patients presented with an adverse local tissue reaction at revision. No differences in mortality, osteolysis or clinical outcome were seen. In conclusion, we found similar results for small-head MoM and CoP bearings up to ten years post-operatively, but after ten years MoM THRs had a higher risk of all-cause revision. Furthermore, the presence of an adverse response to metal debris seen in the small-head MOM group at revision is a cause for concern.
引用
收藏
页码:868 / 875
页数:8
相关论文
共 50 条
  • [31] Predictive role of the Λ ratio in the evaluation of metal-on-metal total hip replacement
    Affatato, S.
    Spinelli, M.
    Zavalloni, M.
    Leardini, W.
    Viceconti, M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H5) : 617 - 628
  • [32] Magnetic resonance imaging of painful metal-on-metal total hip replacement
    Nikolaou V.S.
    Petit A.
    Khoury V.
    Blain-Pare E.
    Zukor D.J.
    Huk O.L.
    Antoniou J.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (2) : 313 - 319
  • [33] Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty
    Anwander, H.
    Cron, G. O.
    Rakhra, K.
    Beaule, P. E.
    BONE & JOINT RESEARCH, 2016, 5 (03): : 73 - 79
  • [34] In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty
    Komistek, RD
    Dennis, DA
    Ochoa, JA
    Haas, BD
    Hammill, C
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10): : 1836 - 1841
  • [35] Serum Metal Ion Concentration: Comparison Between Small and Large Head Metal-on-Metal Total Hip Arthroplasty
    Hallows, Rhett K.
    Pelt, Christopher E.
    Erickson, Jill A.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08): : 1176 - 1181
  • [36] MRI of asymptomatic patients with metal-on-metal and polyethylene-on-metal total hip arthroplasties
    Mistry, A.
    Cahir, J.
    Donell, S. T.
    Nolan, J.
    Toms, A. P.
    CLINICAL RADIOLOGY, 2011, 66 (06) : 540 - 545
  • [37] Metal-on-Metal vs Metal-on-Improved Polyethylene Bearings in Total Hip Arthroplasty
    Molli, Ryan G.
    Lombardi, Adolph V., Jr.
    Berend, Keith R.
    Adams, Joanne B.
    Sneller, Michael A.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (06): : 8 - 13
  • [38] Early failures in large head metal-on-metal total hip arthroplasty
    Althuizen, Martje N. R.
    Hooff, Miranda L. V.
    Erp, Saskia H. M. V. D. Berg-v.
    Limbeek, Jacques V.
    Nijhof, Marc W.
    HIP INTERNATIONAL, 2012, 22 (06) : 641 - 647
  • [39] Similar incidence of periprosthetic fluid collections after ceramic-on-polyethylene total hip arthroplasties and metal-on-metal resurfacing arthroplasties RESULTS OF A SCREENING METAL ARTEFACT REDUCTION SEQUENCE-MRI STUDY
    Bisseling, P.
    de Wit, B. W. K.
    Hol, A. M.
    van Gorp, M. J.
    van Kampen, A.
    van Susante, J. L. C.
    BONE & JOINT JOURNAL, 2015, 97B (09): : 1175 - 1182
  • [40] Cementless metal-on-metal versus ceramic-on-polyethylene hip arthroplasty in under-50 year-olds with 20 to 22 years' follow-up: Was it a good idea to abandon the small-diameter metal-on-metal bearing?
    Grelier, Matthieu
    Martinot, Pierre
    Dartus, Julien
    Migaud, Henri
    Putman, Sophie
    Girard, Julien
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (01)