Improvement of elastographic displacement estimation using a two-step cross-correlation method

被引:57
|
作者
Chen, Hao
Shi, Hairong
Varghese, Tomy [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Elect & Comp Engn, Madison, WI 53706 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2007年 / 33卷 / 01期
关键词
cross-correlation; elastography; elasticity; strain; resolution; signal-to-noise ratio; contrast-to-noise ratio;
D O I
10.1016/j.ultrasmedbio.2006.07.022
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The cross-correlation algorithm used to compute the local strain components for elastographic imaging requires a minimum radio-frequency data segment length of around 10 wavelengths to obtain accurate and precise strain estimates with a reasonable signal-to-noise ratio. Shorter radio-frequency data segments generally introduce increased estimation errors as the information content in the data segment reduces. However, shorter data segments and increased overlaps are essential to improve the axial resolution in the strain image. In this paper, we propose a two-step cross-correlation technique that enables the use of window lengths on the order of a single wavelength to provide displacement and strain estimates with similar noise properties as those obtained with a 10 wavelength window. The first processing step utilizes a window length on the order of 10 wavelengths to obtain coarse displacement estimates between the pre- and postcompression radio frequency data is then interpolated and utilized as the initial guess-estimate for the second cross-correlation processing step using the smaller window. This step utilizes a single wavelength window to improve the axial resolution in strain estimation, without significantly compromising the noise properties of the image. Simulation and experimental results show that the signal-to-noise and contrast-to-noise ratio estimates improve significantly at the smaller window lengths with the two-step processing when compared with the use of a similar sized window in the currently utilized single window method. (E-mail: tvarghese@wisc.edu) (c) 2006 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:48 / 56
页数:9
相关论文
共 50 条
  • [41] Cuffless Blood Pressure Estimation Using Single Channel Photoplethysmography: A Two-Step Method
    Khalid, Syed Ghufran
    Liu, Haipeng
    Zia, Tahir
    Zhang, Jufen
    Chen, Fei
    Zheng, Dingchang
    IEEE ACCESS, 2020, 8 : 58146 - 58154
  • [42] Estimation of solar radiation using two-step method in Yangtze River basin in China
    Chen, Ji-Long
    Xiao, Bei-Bei
    Chen, Chun-Di
    Wen, Zhao-Fei
    Jiang, Yi
    Lv, Ming-Quan
    Wu, Sheng-Jun
    Li, Guo-Sheng
    MAUSAM, 2015, 66 (02): : 225 - 236
  • [43] Relative sensor registration with two-step method for state estimation
    Ge, Quanbo
    Chen, Tianxiang
    Duan, Zhansheng
    Liu, Mingxin
    Niu, Zhuyun
    COGNITIVE COMPUTATION AND SYSTEMS, 2019, 1 (02) : 45 - 54
  • [44] Performance Improvement of Fresnel Beamforming Using Dual Apodization With Cross-Correlation
    Nguyen, Man M.
    Yen, Jesse T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (03) : 451 - 462
  • [45] IMPROVEMENT OF CROSS-CORRELATION PEAKS BY IMAGE FILTERING
    ARNOT, NR
    SAXTON, WO
    OPTIK, 1979, 53 (04): : 271 - 279
  • [46] Improvement of the two-step Richardson algorithm
    Buledza, AV
    CYBERNETICS AND SYSTEMS ANALYSIS, 1995, 31 (06) : 927 - 930
  • [47] Ultrasonic Imaging using two dimensional cross-correlation function
    Ing, RK
    Fourneaux, P
    Fink, M
    1998 IEEE ULTRASONICS SYMPOSIUM - PROCEEDINGS, VOLS 1 AND 2, 1998, : 825 - 829
  • [48] Cross-correlation of two interacting conductors
    Goorden, M. C.
    Buettiker, M.
    PHYSICAL REVIEW B, 2008, 77 (20):
  • [49] Two-Dimensional DOA Estimation Using Cross-Correlation Matrix With L-Shaped Array
    Tayem, Nizar
    Majeed, Khaqan
    Hussain, Ahmed A.
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2016, 15 : 1077 - 1080
  • [50] Underground Imaging Method Using Magnified Cross-Correlation Analysis
    Ha, Euiseong
    Kawamura, Youhei
    Mizutani, Koichi
    Kamohara, Akihiro
    Okawa, Hirokazu
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (05) : 3946 - 3951