Percutaneous closure of perimembranous ventricular septal defects utilizing almost ideal Amplatzer Duct Occluder II: Why limitation in sizes?

被引:8
|
作者
Esmaeili, Anoosh [1 ]
Behnke-Hall, Kachina [1 ]
Schrewe, Roland [1 ]
Schranz, Dietmar [1 ]
机构
[1] Goethe Univ, Pediat Heart Ctr Hessen, Frankfurt, Germany
关键词
Amplatzer Duct Occluder II; pediatric; perimembranous ventricular septal defect; transcatheter closure; MEMBRANOUS VSD OCCLUDER; TRANSCATHETER CLOSURE; DEVICE CLOSURE; IMMEDIATE;
D O I
10.1111/chd.12731
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim The purpose of this study is to describe the special aspects of perimembranous ventricular septal defects (pmVSD) closure by utilizing Amplatzer Duct Occluder II (ADO II) devices with a rational request for bigger ADO-II sizes, based on our experience in transcatheter device closure of pmVSD. Methods and Results At our institution, placement of an ADO II device was used in 15 patients with pmVSD; the patients' age ranged between 6 months and 20 years. The indications for closure were CHF (n = 4), hemodynamically significant shunt (n = 7), tricuspid regurgitation (n = 3), and high risk for infective endocarditis (n = 2), respectively. The location of the VSD was infracristal in 13 patients, supracristal in 1, and a postsurgical Gerbode VSD in another one. Implantation of the device was successfully performed without embolization, any evidence of an AV block, or other conductance abnormalities during implantation and follow-up in the mean of 2.5 years (range 2 months-6.5 years). Conclusions Transcatheter closure of a pmVSD with ADO II is feasible in all pediatric and young adult age groups, by considering the device diameter limitations. The off-label use of ADO II implantation seems to be safe for VSDs closure up to 6 mm of size and feasible for various locations including unusual morphology such as postsurgical Gerbode defect.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 50 条
  • [21] Transcatheter closure of perimembranous ventricular septal defects with the amplatzer asymmetric ventricular septal defect occluder: Preliminary experience in children
    Thanopoulos, BD
    Tsaousis, GS
    Karanasios, E
    Stefanadis, C
    Sophia, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 473A - 473A
  • [22] Ten Year Experience with Transcatheter Closure of Perimembranous Ventricular Septal Defects Using the Amplatzer Asymmetric Perimembranous Ventricular Septal Defect Occluder in Children
    Thanopoulos, Vasileios
    Giannopoulos, Andreas
    Tsaousis, George
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B225 - B225
  • [23] Follow-Up of Patients with Interventional Closure of Ventricular Septal Defects with Amplatzer Duct Occluder II
    M. Kanaan
    P. Ewert
    F. Berger
    S. Assa
    S. Schubert
    Pediatric Cardiology, 2015, 36 : 379 - 385
  • [24] Intraoperative imaging of hybrid procedure for muscular ventricular septal defects closure with Amplatzer Duct Occluder II
    Chojnicki, Maciej
    Haponiuk, Ireneusz
    Jaworski, Radoslaw
    Juscinski, Jacek
    Steffek, Mariusz
    Sroka, Mariusz
    Palkowska, Lucyna
    KARDIOLOGIA POLSKA, 2011, 69 (12) : 1280 - 1281
  • [25] RETROGRADE TRANSCATHETER CLOSURE OF VENTRICULAR SEPTAL DEFECTS IN CHILDREN USING THE AMPLATZER DUCT OCCLUDER II DEVICE
    Koneti, Nageswara Rao
    Penumatsa, Raghava
    Arramraju, Sreenivas
    Vadlamudi, Karunakar
    Sreeram, Narayanswami
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E814 - E814
  • [26] Percutaneous closure of perimembranous ventricular septal defects with Amplatzer occluders - a single centre experience
    Szkutnik, Malgorzata
    Kusa, Jacek
    Bialkowski, Jacek
    KARDIOLOGIA POLSKA, 2008, 66 (09) : 941 - 949
  • [27] Follow-Up of Patients with Interventional Closure of Ventricular Septal Defects with Amplatzer Duct Occluder II
    Kanaan, M.
    Ewert, P.
    Berger, F.
    Assa, S.
    Schubert, S.
    PEDIATRIC CARDIOLOGY, 2015, 36 (02) : 379 - 385
  • [28] Percutaneous closure of perimembranous ventricular septal defects with the amplatzer device: Technical and morphological considerations
    Pedra, CAC
    Pedra, SRF
    Esteves, CA
    Pontes, SC
    Braga, SLN
    Arrieta, SR
    Santana, MVT
    Fontes, VF
    Masura, J
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (03) : 403 - 410
  • [29] Ventricular Septal Defect Closure in a Small Children With the Amplatzer Duct Occluder II
    El Tahlawi, Mohammad
    Kammache, Issam
    Fraisse, Alain
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (02) : 268 - 271
  • [30] Retrograde transcatheter closure of ventricular septal defect with Amplatzer Duct Occluder II
    Suligoj, Brina
    Cernic, Natasa
    Zorc, Metka
    Noc, Marko
    Kar, Saibal
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2016, 12 (02): : 177 - 178