Effect of Fire Damage on Seismic Behavior of Cast-in-Place Reinforced Concrete Columns

被引:1
|
作者
Demir, Ugur [1 ]
Goksu, Caglar [1 ]
Unal, Goktug [2 ,3 ]
Green, Mark [4 ]
Ilki, Alper [1 ]
机构
[1] Istanbul Tech Univ, Civil Engn Fac, TR-34469 Istanbul, Turkey
[2] Istanbul Tech Univ, Earthquake Engn & Disaster Management Inst, TR-34469 Istanbul, Turkey
[3] Erzincan Binali Yildirim Univ, Fac Engn, Dept Civil Engn, TR-24100 Erzincan, Turkey
[4] Queens Univ, Fac Engn & Appl Sci, Kingston, ON K7L 3N6, Canada
关键词
Columns; Earthquake engineering; Fire; Reinforced concrete; Seismic; MECHANICAL-PROPERTIES; PERFORMANCE; RESISTANCE; EXPOSURE;
D O I
10.1061/SSCEST.1943-541X.0002794
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of an experimental study that was conducted to investigate the postfire seismic behavior of reinforced concrete columns. Five full-scale, flexure-critical code-complying (e.g., ACI 318-14) cast-in-place reinforced concrete columns were tested to failure under a constant axial load and reversed cyclic lateral displacements after being exposed to an ISO-834 standard fire for 30, 60, and 90 min. Other than the effects of the duration of the fire exposure, the effects of the thickness of the concrete cover (25 and 40 mm) on the structural performance was also investigated for the short fire exposure duration (30 min). The responses of the columns were analyzed in terms of lateral load-displacement relationships, ductility, stiffness, energy dissipation capacities, and residual displacements. The test results indicated that the fire exposure reduced the lateral load capacity of the columns, whereas the deformability capabilities were found to be satisfactory in terms of a structural response. It was also observed that the thickness of the concrete cover had only a slight influence on the postfire seismic behavior of the columns. Furthermore, a numerical study was conducted to predict the load-displacement response of the fire exposed columns. The comparison of the experimentally and numerically obtained load-displacement relationships indicated that the principles of structural mechanics usually applied to conventional columns are also valid for the columns exposed to fire. (c) 2020 American Society of Civil Engineers.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Cyclic Loading Test for Cast-in-Place Concrete-Filled Hollow Precast Concrete Columns
    Kim, Chang-Soo
    Lim, Woo-Young
    Park, Hong-Gun
    Oh, Jung-Keun
    ACI STRUCTURAL JOURNAL, 2016, 113 (02) : 205 - 215
  • [22] Fire behaviours of concrete columns with prior seismic damage
    Wu, Bo
    Xiong, Wei
    Liu, Fentao
    MAGAZINE OF CONCRETE RESEARCH, 2017, 69 (07) : 365 - 378
  • [23] Cyclic behavior of precast concrete beam-column connection using steel fiber reinforced cast-in-place concrete
    Noorhidana, Vera Agustriana
    Forth, John P.
    MATERIALS SCIENCE-POLAND, 2021, 39 (02) : 240 - 251
  • [24] Seismic damage assessment of reinforced concrete bridge columns
    Kim, TH
    Lee, KM
    Chung, YS
    Shin, HM
    ENGINEERING STRUCTURES, 2005, 27 (04) : 576 - 592
  • [25] Cast-in-place cellulose fiber-reinforced cement paste, mortar, and concrete
    Rapoport, JR
    Shah, SR
    ACI MATERIALS JOURNAL, 2005, 102 (05) : 299 - 306
  • [26] LOAD-DEFLECTION BEHAVIOR OF CAST-IN-PLACE AND RETROFIT CONCRETE ANCHORS
    COOK, RA
    COLLINS, DM
    KLINGNER, RE
    POLYZOIS, D
    ACI STRUCTURAL JOURNAL, 1992, 89 (06) : 639 - 649
  • [27] STANDARD PRACTICE FOR THE DESIGN AND CONSTRUCTION OF CAST-IN-PLACE REINFORCED CONCRETE CHIMNEYS.
    Balles, Peter J.
    Blanchard, Raymond
    Bochicchio, Victor A.
    Bonnet, Henry P.
    Cassidy, Arthur P.
    Chugh, Khushi R.
    Davidson, Philip B.
    ACI Structural Journal, 1988, 85 (01) : 99 - 101
  • [28] Summary Of Research On Seismic Behavior Of Precast Column System With The Same Effect As The Cast-In-Place Column
    Zhou, Mi
    Zeng, Hang
    2018 3RD INTERNATIONAL CONFERENCE ON SMART CITY AND SYSTEMS ENGINEERING (ICSCSE), 2018, : 150 - 154
  • [29] Precast Concrete Modules combined with Cast-in-place Concrete
    不详
    BAUINGENIEUR, 2013, 88 : A13 - A13
  • [30] CAST-IN-PLACE CONCRETE RESIDENCES WITH INSULATED WALLS
    SCOGGIN, HL
    JOURNAL OF THE PCA RESEARCH AND DEVELOPMENT LABORATORIES, 1966, 8 (02): : 21 - &