P-wave evidence as a method for improving algorithm to detect atrial fibrillation in insertable cardiac monitors

被引:100
|
作者
Puererfellner, Helmut [1 ]
Pokushalov, Evgeny [2 ]
Sarkar, Shantanu [3 ]
Koehler, Jodi [3 ]
Zhou, Ren [3 ]
Urban, Lubos [4 ]
Hindricks, Gerhard [5 ]
机构
[1] Krankenhaus Elisabethinen, Dept Cardiol, Linz, Austria
[2] State Res Inst Circulat Pathol, Novosibirsk, Russia
[3] Medtronic Inc, Mounds View, MN USA
[4] Natl Inst Cardiovasc Dis, Bratislava, Slovakia
[5] Univ Leipzig, Ctr Heart, D-04109 Leipzig, Germany
关键词
Atrial fibrillation; Insertable cardiac monitors; Diagnosis; Monitoring; CATHETER ABLATION; CRYPTOGENIC STROKE; FOLLOW-UP; RECORDER; EPISODES; BURDEN; RISK;
D O I
10.1016/j.hrthm.2014.06.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Frequent premature atrial contractions and sick sinus syndrome are primary causes of inappropriate atrial fibrillation (AF) detection in insertable cardiac monitors (ICMs). OBJECTIVE The study aimed to validate an algorithm designed to reduce inappropriate AF detection on the basis of the identification of a single P wave during the cardiac cycle. METHODS The original detection algorithm looks for evidence of AF based on differences in the pattern of R-R intervals over a 2-minute period. The improved algorithm reduces evidence for AF detection if P waves are detected. The algorithm was validated by using Hater data, which collected 2 leads of surface electrocardiogram and continuously uplinked ICM electrocardiogram over a 46-hour period. ICM detections were compared with Holter annotations to compute episode and duration detection performance. RESULTS Valid Holler recordings (8442 hours) were analyzed from 206 patients. True AF was observed in 76 patients, yielding 482 true AF episodes >= 2 minutes in duration and 1191 hours of AF. The algorithm correctly identified 97.8% of the total AF duration and 99.3% of the total sinus or non-AF rhythm duration. The algorithm detected 85% (90% per-patient average) of all AF episodes >= 2 minutes in duration, and 55% (78% per-patient average) of the detected episodes had AF. AF was found in 95 % of the detected episodes >1 hour. The improved algorithm reduced inappropriate episodes and duration by 46% and 55%, respectively, while also reducing appropriate episodes and duration by 2% and 0.1 %, respectively. CONCLUSION An improvement in the ICM algorithm for AF detection incorporating P-wave information substantially reduced inappropriately detected episodes and duration, with minimal reduction in sensitivity for detecting AF.
引用
收藏
页码:1575 / 1583
页数:9
相关论文
共 50 条
  • [21] Role of insertable cardiac monitors in anticoagulation therapy in patients with atrial fibrillation at high risk of bleeding
    Mascarenhas, Daniel A. N.
    Farooq, Mohammad U.
    Ziegler, Paul D.
    Kantharia, Bharat K.
    EUROPACE, 2016, 18 (06): : 799 - 806
  • [22] Cryptogenic stroke and atrial fibrillation in a real-world population: the role of insertable cardiac monitors
    De Angelis, Maria Vittoria
    Di Stefano, Vincenzo
    Franciotti, Raffaella
    Furia, Nanda
    Di Girolamo, Enrico
    Onofrj, Marco
    Faustino, Massimiliano
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [23] Real-World Experience with Insertable Cardiac Monitors to Find Atrial Fibrillation in Cryptogenic Stroke
    Ziegler, Paul D.
    Rogers, John D.
    Ferreira, Scott W.
    Nichols, Allan J.
    Sarkar, Shantanu
    Koehler, Jodi L.
    Warman, Eduardo N.
    Richards, Mark
    CEREBROVASCULAR DISEASES, 2015, 40 (3-4) : 175 - 181
  • [24] IMPLANTABLE CARDIAC MONITORS (BIOMONITOR 2-AF, CONFIRM RX INSERTABLE CARDIAC MONITOR AND REVEAL LINQ INSERTABLE CARDIAC MONITORING SYSTEM) TO DETECT ATRIAL FIBRILLATION AFTER CRYPTOGENIC STROKE: A SYSTEMATIC REVIEW
    Wakefield, V
    Edwards, S. J.
    Kew, K.
    Jhita, T.
    Cain, P.
    Marceniuk, G.
    VALUE IN HEALTH, 2019, 22 : S669 - S669
  • [25] The signal-averaged P-wave to predict atrial fibrillation after cardiac surgery
    Archbold, RA
    ANNALS OF THORACIC SURGERY, 2006, 81 (01): : 406 - 407
  • [26] P-wave characteristics and atrium voltage mapping in cardiac amyloidosis with paroxysmal atrial fibrillation
    Ohe, Masatsugu
    Tahara, Nobuhiro
    Ueda, Mitsuharu
    Fukumoto, Yoshihiro
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2023, 7 (07)
  • [27] Risk assessment for atrial fibrillation: Enter the P-wave
    Magnani, Jared W.
    HEART RHYTHM, 2015, 12 (09) : 1896 - 1897
  • [28] Looking for Atrial Fibrillation With Insertable Cardiac Monitors-Is 1 Year Long Enough and Does it Matter?
    Buck, Brian H.
    Sposato, Luciano A.
    Field, Thalia S.
    JAMA NEUROLOGY, 2023, 80 (12) : 1266 - 1268
  • [29] Reimagining Cryptogenic Stroke Care: Collaborative Care and Inpatient Insertable Cardiac Monitors for Detection of Atrial Fibrillation
    Herial, Nabeel A.
    Frisch, Daniel R.
    Miller, Elan
    Patel, Priyadarshee
    Munoz, Alfredo
    Warren, Melissa
    Khalife, Jane
    Majmundar, Shyam
    Farkas, Nathan
    Alam, Shaista
    Dharia, Robin
    Pavri, Behzad B.
    Tzeng, Diana
    Ho, Reginald T.
    Greenspon, Arnold
    Bell, Rodney
    Jabbour, Pascal
    Rosenwasser, Robert
    STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2024, 4 (06):
  • [30] P-wave Analysis in Atrial Fibrillation Detection Using a Neural Network Clustering Algorithm
    Firoozabadi, Reza
    Gregg, Richard E.
    Babaeizadeh, Saeed
    2018 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2018, 45