THE NEUTRON DOSE EQUIVALENT AROUND HIGH ENERGY MEDICAL ELECTRON LINEAR ACCELERATORS

被引:8
|
作者
Poje, Marina [1 ]
Ivkovic, Ana [2 ]
Jurkovic, Slaven [3 ]
Zauhar, Gordana [4 ]
Vukovic, Branko [1 ]
Radolic, Vanja [1 ]
Miklavcic, Igor [1 ]
Kaliman, Zoran [5 ]
Planinic, Josip [1 ]
Brkic, Hrvoje [6 ]
Faj, Dario [6 ]
机构
[1] Univ Josip Juraj Strossnnayer, Dept Phys, Osijek, Croatia
[2] Univ Hosp Ctr Osijek, Osijek, Croatia
[3] Univ Hosp Rijeka, Dept Med Phys, Rijeka, Croatia
[4] Univ Rijeka, Dept Phys, Fac Med, Rijeka, Croatia
[5] Univ Rijeka, Dept Phys, Rijeka, Croatia
[6] Univ Osijek, Fac Med, Osijek, Croatia
来源
关键词
radiotherapy; electron linear accelerator; neutron equivalent dose; RADIOTHERAPY; ROOMS;
D O I
10.2298/NTRP1403207P
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The measurement of neutron dose equivalent was made in four dual energy linear accelerator rooms. Two of the rooms were reconstructed after decommissioning of Co-60 units, so the main limitation was the space. The measurements were performed by a nuclear track etched detectors LR-115 associated with the converter (radiator) that consist of B-10 and with the active neutron detector Thermo BIOREM FHT 742. The detectors were set at several locations to evaluate the neutron ambient dose equivalent and/or neutron dose rate to which medical personnel could be exposed. Also, the neutron dose dependence on collimator aperture was analyzed. The obtained neutron dose rates outside the accelerator rooms were several times smaller than the neutron dose rates inside the accelerator rooms. Nevertheless, the measured neutron dose equivalent was not negligible from the aspect of the personal dosimetry with almost 2 mSv a year per person in the areas occupied by staff (conservative estimation). In rooms with 15 MV accelerators, the neutron exposure to the personnel was significantly lower than in the rooms having 18 MV accelerators installed. It was even more pronounced in the room reconstructed after the Co-60 decommissioning. This study confirms that shielding from the neutron radiation should be considered when building vaults for high energy linear accelerators, especially when the space constraints exist.
引用
收藏
页码:207 / 212
页数:6
相关论文
共 50 条
  • [41] CALCULATION OF RESIDUAL PHOTON DOSE RATE AROUND HIGH-ENERGY PROTON ACCELERATORS
    ARMSTRON.TW
    ALSMILLE.RG
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1969, 12 (01): : 391 - &
  • [42] CALCULATION OF RESIDUAL PHOTON DOSE RATE AROUND HIGH-ENERGY PROTON ACCELERATORS
    ARMSTRONG, TW
    ALSMILLER, RG
    NUCLEAR SCIENCE AND ENGINEERING, 1969, 38 (01) : 53 - +
  • [43] PHOTONEUTRONS FROM HIGH-ENERGY MEDICAL LINEAR ACCELERATORS - MEASUREMENT OF THE SPECTRUM AND DOSE USING A MINIATURE PROPORTIONAL COUNTER
    KLIAUGA, P
    AMOLS, H
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (03): : 629 - 633
  • [44] A REVIEW ON THE RADIATION THERAPY TECHNOLOGIST RECEIVED DOSE FROM INDUCED ACTIVATION IN HIGH-ENERGY MEDICAL LINEAR ACCELERATORS
    Nourmohammadi, Bahareh
    Mesbahi, Asghar
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (04) : 333 - 348
  • [45] A measuring system with a recombination chamber for neutron dosimetry around medical accelerators
    Golnik, N
    Kaminski, P
    Zielczynski, M
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 273 - 276
  • [46] ELECTRON LINEAR ACCELERATORS FOR FAST-NEUTRON DATA MEASUREMENTS IN SUPPORT OF FUSION ENERGY APPLICATIONS
    BOCKHOFF, KH
    CARLSON, AD
    WASSON, OA
    HARVEY, JA
    LARSON, DC
    NUCLEAR SCIENCE AND ENGINEERING, 1990, 106 (02) : 192 - 207
  • [47] HYPERFRACTIONATION - A NEW CHALLENGE TO MEDICAL ELECTRON LINEAR ACCELERATORS
    JENSEN, JM
    IHNEN, E
    GLASER, T
    HILLENBERG, HJ
    KOHR, P
    THOMS, M
    STRAHLENTHERAPIE UND ONKOLOGIE, 1990, 166 (06): : 415 - 419
  • [48] POSSIBLE MEDICAL AND INDUSTRIAL APPLICATION OF LINEAR ELECTRON ACCELERATORS
    BARBER, WC
    ELDREDGE, AL
    GINZTON, EL
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1953, 41 (03): : 422 - 422
  • [49] Optimization of a neutron dosimeter for the high energy accelerators
    Sokolov, Alexey
    Fehrenbacher, Georg
    Kozlova, Ekaterina
    Radon, Torsten
    Zahradnik, Izabella
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153
  • [50] A Passive Neutron Dosemeter for High Energy Accelerators
    A. M. Mamaev
    V. N. Peleshko
    E. N. Savitskaya
    A. V. Sannikov
    M. M. Sukharev
    S. E. Sukhikh
    Instruments and Experimental Techniques, 2020, 63 : 154 - 160