An analytical method for the simultaneous determination of 9 quinolones (QNs) in porcine, chicken, and bovine muscles was developed and validated using liquid chromatography-fluorescence detector (LC-FLD). The samples were extracted using a liquid-liquid extraction (LLE) process. Chromatographic separation was achieved on a reverse phase C-8 column with a gradient elution using a mobile phase of 200 mM ammonium acetate buffer (pH 4.5) and acetonitrile (ACN). The proposed method was validated according to the Food and Drug Administration (FDA) guideline for bioanalytical assay procedures. Recoveries of QNs were 83.1-111.9% with relative standard deviations (RSDs) below 15%. Linearity within a range of 30-500 mu g/kg was obtained with the correlation coefficient (R-2) of 0.9967-0.9999. The limits of detection (LOD) were 1-16 mu g/kg. These values were lower than the maximum residues limits (MRLs) established by the European Union (EU). The present method was successfully applied to determine QNs in edible muscles.
引用
收藏
页码:978 / 984
页数:7