Contact mechanics of modular metal-on-polyethylene total hip replacement under adverse edge loading conditions

被引:48
|
作者
Hua, Xijin [1 ]
Li, Junyan [1 ]
Wang, Ling [2 ]
Jin, Zhongmin [1 ,2 ]
Wilcox, Ruth [1 ]
Fisher, John [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
[2] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, Xian 710049, Shanxi, Peoples R China
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
Microseparation; Edge loading; Metal-on-polyethylene; Contact mechanics; Total hip replacement; FINITE-ELEMENT-ANALYSIS; MOLECULAR-WEIGHT POLYETHYLENE; IN-VIVO DETERMINATION; CUP ANGLE; RESURFACING ARTHROPLASTY; ACETABULAR COMPONENTS; WEAR RATES; MICROSEPARATION; ALUMINA; PROSTHESES;
D O I
10.1016/j.jbiomech.2014.08.015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Edge loading can negatively impact the biomechanics and long-term performance of hip replacements. Although edge loading has been widely investigated for hard-on-hard articulations, limited work has been conducted for hard-on-soft combinations. The aim of the present study was to investigate edge loading and its effect on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip replacement (THR). A three-dimensional finite element model was developed based on a modular MoP bearing. Different cup inclination angles and head lateral microseparation were modelled and their effect on the contact mechanics of the modular MoP hip replacement were examined. The results showed that lateral microseparation caused loading of the head on the rim of the cup, which produced substantial increases in the maximum von Mises stress in the polyethylene liner and the maximum contact pressure on both the articulating surface and backside surface of the liner. Plastic deformation of the liner was observed under both standard conditions and microseparation conditions, however, the maximum equivalent plastic strain in the liner under microseparation conditions of 2000 gm was predicted to be approximately six times that under standard conditions. The study has indicated that correct positioning the components to avoid edge loading is likely to be important clinically even for hard-on-soft bearings for THR. (C) 2014 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license
引用
收藏
页码:3303 / 3309
页数:7
相关论文
共 50 条
  • [21] In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty
    Komistek, RD
    Dennis, DA
    Ochoa, JA
    Haas, BD
    Hammill, C
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10): : 1836 - 1841
  • [22] Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty
    Anwander, H.
    Cron, G. O.
    Rakhra, K.
    Beaule, P. E.
    BONE & JOINT RESEARCH, 2016, 5 (03): : 73 - 79
  • [23] Serum Metal Levels for Diagnosis of Adverse Local Tissue Reactions Secondary to Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty
    Fillingham, Yale A.
    Della Valle, Craig J.
    Bohl, Daniel D.
    Kelly, Mick P.
    Hall, Deborah J.
    Pourzal, Robin
    Jacobs, Joshua J.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (09): : S272 - S277
  • [24] A closed-form formulation for the conformal articulation of metal-on-polyethylene hip prostheses: Contact mechanics and sliding distance
    Askari, Ehsan
    Andersen, Michael S.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (12) : 1196 - 1208
  • [25] Trunnionosis in metal-on-polyethylene total hip arthroplasties: Report two cases
    Taheriazam, Afshin
    Baghbani, Salar
    Amiri, Shayan
    Jahanshahi, Fatemeh
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2023, 109
  • [26] Adverse local tissue reactions in metal-on-polyethylene total hip arthroplasty due to trunnion corrosion THE RISK OF MISDIAGNOSIS
    Whitehouse, M. R.
    Endo, M.
    Zachara, S.
    Nielsen, T. O.
    Greidanus, N. V.
    Masri, B. A.
    Garbuz, D. S.
    Duncan, C. P.
    BONE & JOINT JOURNAL, 2015, 97B (08): : 1024 - 1030
  • [27] MRI, Retrieval Analysis, and Histologic Evaluation of Adverse Local Tissue Reaction in Metal-on-Polyethylene Total Hip Arthroplasty
    Nodzo, Scott R.
    Esposito, Christina I.
    Potter, Hollis G.
    Ranawat, Chitranjan S.
    Wright, Timothy M.
    Padgett, Douglas E.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (05): : 1647 - 1653
  • [28] Metal-on-Metal Compared With Metal-on-Polyethylene: The Effect on Trunnion Corrosion in Total Hip Arthroplasty
    Lanting, Brent A.
    Teeter, Matthew G.
    Howard, James L.
    MacDonald, Steven J.
    Van Citters, Douglas W.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (08): : 2574 - 2579
  • [29] Combined wear and ageing of ceramic-on-ceramic bearings in total hip replacement under edge loading conditions
    Al-Hajjar, Mazen
    Gremillard, Laurent
    Begand, Sabine
    Oberbach, Thomas
    Hans, Karen
    Delfosse, Daniel
    Chevalier, Jerome
    Jennings, Louise M.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 98 : 40 - 47
  • [30] Outcome of Re-Revision Surgery for Adverse Local Tissue Reaction in Metal-on-Polyethylene and Metal-on-Metal Total Hip Arthroplasty
    Bonner, Bryant
    Arauz, Paul
    Klemt, Christian
    Kwon, Young-Min
    JOURNAL OF ARTHROPLASTY, 2020, 35 (06): : S284 - S288