Nickel Hydroxide Nanoflowers for a Nonenzymatic Electrochemical Glucose Sensor

被引:39
|
作者
Yang, Haipeng [1 ]
Gao, Guangwei [1 ]
Teng, Fei [2 ]
Liu, Wenjun [1 ]
Chen, Shaojun [1 ]
Ge, Zaochuan [1 ]
机构
[1] Shenzhen Univ, Coll Mat Sci & Engn, Shenzhen Key Lab Special Funct Mat, Shenzhen 518060, Peoples R China
[2] Nanjing Univ Informat Sci & Technol, Sch Environm Sci & Engn, Jiangsu Key Lab Atmospher Environm Monitoring & P, Nanjing 210044, Jiangsu, Peoples R China
关键词
GLASSY-CARBON ELECTRODE; GOLD NANOPARTICLES; HYDROGEN-PEROXIDE; PLATINUM; COMPOSITE; NANOCOMPOSITES; DEHYDROGENASE; SENSITIVITY; BIOSENSORS; ARRAYS;
D O I
10.1149/2.0521410jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Nickel hydroxide nanoflowers (f-Ni(OH)(2)) were synthesized in present work. The crystal structure of as-prepared sample is beta-Ni(OH)(2) phase (JCPDS # 14-0117). A nano composite film was fabricated by dispersing nano scale f-Ni(OH)(2) and carbon nanotubes (CNTs) into Nafion solution. The electrocatalytic oxidation of glucose in alkaline medium on the f-Ni(OH)(2)-CNT-Nafion composite (fNCN) modified glass carbon electrode (GCE) had been investigated. The prepared f-Ni(OH)(2)-CNT-Nafion / Glass Carbon electrode (fNCN/GCE) glucose sensor could produce large electrocatalytic oxidation current in glucose solution when the "applied potential exceeds 0.32 V vs. SCE, which is much lower than the similar sensor based on Ni(OH)(2) nanosheets (s-Ni(OH)(2)) and is comparable to alpha-Ni(OH)(2) sensor. Amperometric measurements were done with different concentrations of glucose. The fNCN/GCE glucose sensor has high sensitivity and low detection limit at a potential of 0.45 V (vs. SCE). It showed a detection limit of 0.5 mu M (S/N = 3) and a sensitivity of 16.85 mu A mM(-1) (238.5 mu A mM(-1) cm(-2)) with a linear range from 0.1 to 1.1 mM. The K-m derived from Lineweaver-Burk equation is evaluated to be 4.25 mM, which is much lower than enzymatic glucose biosensor. (C) 2014 The Electrochemical Society. All rights reserved.
引用
收藏
页码:B216 / B219
页数:4
相关论文
共 50 条
  • [21] Gold nanodots-decorated nickel hydroxide nanoflowers for enhanced electrochemical oxygen evolution activity
    Mai, Hien Duy
    Kim, Suncheol
    Yoo, Hyojong
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2020, 82 : 359 - 366
  • [22] Nonenzymatic electrochemical glucose sensor based on MnO2/MWNTs nanocomposite
    Chen, Jin
    Zhang, Wei-De
    Ye, Jian-Shan
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (09) : 1268 - 1271
  • [23] Nonenzymatic Electrochemical Sensor for Glucose Based on Nanoporous Platinum-Gold Alloy
    Wang, Jinping
    Zhao, Dianyun
    Xu, Caixia
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2016, 16 (07) : 7145 - 7150
  • [24] Nonenzymatic Electrochemical Glucose Sensor Based on Pt Nanoparticles/Mesoporous Carbon Matrix
    Su, Chang
    Zhang, Cheng
    Lu, Guoqiang
    Ma, Chunan
    ELECTROANALYSIS, 2010, 22 (16) : 1901 - 1905
  • [25] Copper nanoparticles/polyaniline/molybdenum disulfide composite as a nonenzymatic electrochemical glucose sensor
    Sharma, Krishna Prasad
    Shin, Miyeon
    Kim, Kyong
    Woo, Kyungmin
    Awasthi, Ganesh Prasad
    Yu, Changho
    HELIYON, 2023, 9 (12)
  • [26] Sensitive detection of glucose using a nonenzymatic electrochemical sensor based on nanoporous palladium
    Lu, Lu
    Cui, Bo
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2018, 123 : 24 - 25
  • [27] Nonenzymatic electrochemical glucose sensor based on novel Pt-Pd nanoflakes
    Niu, Xiangheng
    Lan, Minbo
    Chen, Chen
    Zhao, Hongli
    TALANTA, 2012, 99 : 1062 - 1067
  • [28] Nonenzymatic Glucose Sensor: Glassy Carbon Electrode Modified with Graphene-Nickel/Nickel Oxide Composite
    Kumary, V. Anitha
    Nancy, T. E. Mary
    Divya, J.
    Sreevalsan, K.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (02): : 2220 - 2228
  • [29] Nonenzymatic Glucose Sensor Based on Platinum Nanoflowers Decorated Multiwalled Carbon Nanotubes-Graphene Hybrid Electrode
    Badhulika, Sushmee
    Paul, Rajat Kanti
    Rajesh
    Terse, Trupti
    Mulchandani, Ashok
    ELECTROANALYSIS, 2014, 26 (01) : 103 - 108
  • [30] Amperometric nonenzymatic glucose sensor based on a glassy carbon electrode modified with a nanocomposite made from nickel(II) hydroxide nanoplates and carbon nanofibers
    Zhang, Li
    Yuan, Sheng-mei
    Lu, Xiao-jing
    MICROCHIMICA ACTA, 2014, 181 (3-4) : 365 - 372