Cation-selective electropreconcentration

被引:19
|
作者
Shin, Il Hyung [1 ]
Kim, Ki-jung [1 ]
Kim, Jiman [1 ]
Kim, Hee Chan [1 ]
Chun, Honggu [2 ]
机构
[1] Seoul Natl Univ, Dept Biomed Engn, Seoul, South Korea
[2] Korea Univ, Dept Biomed Engn, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
IONIZATION MASS-SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; SAMPLE PRECONCENTRATION; CONCENTRATION POLARIZATION; MICROFLUIDIC DEVICES; CHIP; PROTEINS; FLOW; MICROCHIP; STACKING;
D O I
10.1039/c4lc00024b
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A cation-selective microfluidic sample preconcentration system is described. The cation sample was electropreconcentrated using a reversed-direction electroosmotic flow (EOF) and an anion-permselective filter, where an electric double layer (EDL) overlap condition existed. The anion-permselective filter between microchannels was fabricated by three different methods: 1) extending a positively charged, nanoporous, polymer membrane by photopolymerization of poly(diallyldimethylammonium chloride) (PDADMAC); 2) etching a nanochannel and then coating it with a positively-charged monomer, N-[3(trimethoxysilyl)propyl]-N'-(4-vinylbenzyl)ethylenediamine hydrochloride (TMSVE); and, 3) etching a nanochannel and then coating it with a positively-charged, pre-formed polymer, polyE-323. The EOF direction in the microchannel was reversed by both TMSVE and polyE-323 coatings. The cation-selective preconcentration was investigated using charged fluorescent dyes and tetramethylrhodamine isothiocyanate (TRITC)-tagged peptides/proteins. The preconcentration in the three different systems was compared with respect to efficiency, dependence on buffer concentration and pH, tolerable flow rate, and sample adsorption. Both TMSVE- and polyE-323-coated nanochannels showed robust preconcentration at high flow rates, whereas the PDADMAC membrane maintained anion- permselectivity at higher buffer concentrations. The TMSVE-coated nanochannels showed a more stable preconcentration process, whereas the polyE-323-coated nanochannels showed a lower peptide sample adsorption and robust efficiency under a wide range of buffer pHs. The system described here can potentially be used for the preconcentration of cationic peptides/proteins on microfluidic devices for subsequent analyses.
引用
收藏
页码:1811 / 1815
页数:5
相关论文
共 50 条
  • [21] The mitochondrial channel VDAC has a cation-selective open state
    Pavlov, E
    Grigoriev, SM
    Dejean, LM
    Zweihorn, CL
    Mannella, CA
    Kinnally, KW
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 2005, 1710 (2-3): : 96 - 102
  • [22] ROLE OF AN APICAL CATION-SELECTIVE CHANNEL IN FUNCTION OF TIGHT EPITHELIA
    VANDRIESSCHE, W
    ERLIJ, D
    SIMAELS, J
    BIOLOGY OF THE CELL, 1989, 66 (1-2) : 37 - 41
  • [23] Synthetic cation-selective nanotube: Permeant cations chaperoned by anions
    Hilder, Tamsyn A.
    Gordon, Dan
    Chung, Shin-Ho
    JOURNAL OF CHEMICAL PHYSICS, 2011, 134 (04):
  • [24] DOUBLE MATRIX MEMBRANES FOR POTENTIOMETRIC CATION-SELECTIVE DISPOSABLE SENSORS
    DUMSCHAT, C
    BORCHARDT, M
    DIEKMANN, C
    HEPKE, J
    CAMMANN, K
    KNOLL, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (8-9): : 553 - 555
  • [25] ELECTROOSMOSIS IN CATION-SELECTIVE COLLODION MATRIX MEMBRANES OF GRADED POROSITY
    CARR, CW
    MCCLINTOCK, R
    SOLLNER, K
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1962, 109 (03) : 251 - 255
  • [26] CATION-SELECTIVE CHANNELS IN AMPHIBIAN EPITHELIA - ELECTROPHYSIOLOGICAL PROPERTIES AND ACTIVATION
    VANDRIESSCHE, W
    SIMAELS, J
    AELVOET, I
    ERLIJ, D
    COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-PHYSIOLOGY, 1988, 90 (04): : 693 - 699
  • [27] Cation-Selective Channel Regulated by Anions According to Their Hofmeister Ranking
    Gurnev, Philip A.
    Roark, Torri C.
    Petrache, Horia I.
    Sodt, Alexander J.
    Bezrukov, Sergey M.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2017, 56 (13) : 3506 - 3509
  • [28] Nickel hexacyanoferrate membrane as a coated wire cation-selective electrode
    Giorgetti, M
    Scavetta, E
    Berrettoni, M
    Tonelli, D
    ANALYST, 2001, 126 (12) : 2168 - 2171
  • [29] Hydrophilic sensor membrane based on cation-selective protic chromoionophore
    Krause, C
    Werner, T
    Huber, C
    Wolfbeis, OS
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 367 (05): : 426 - 428
  • [30] MXene as a Cation-Selective Cathode Material for Asymmetric Capacitive Deionization
    Chen, Bingbing
    Feng, Aihu
    Deng, Ruixiang
    Liu, Kun
    Yu, Yun
    Song, Lixin
    ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (12) : 13750 - 13758