Effect of oxidative stress on membrane structure: Small-angle x-ray diffraction analysis

被引:97
|
作者
Mason, RP [1 ]
Walter, MF [1 ]
Mason, PE [1 ]
机构
[1] ALLEGHENY UNIV HLTH SCI,CTR RES NEUROSCI,MCP HAHNEMANN SCH MED,DEPT BIOCHEM,PITTSBURGH,PA 15212
关键词
lipid peroxidation; x-ray diffraction; cardiac membrane structure;
D O I
10.1016/S0891-5849(97)00101-9
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Free radical damage to cellular membranes appears to underlie alterations in function in aging and various pathological processes, including cardiovascular disease. The objective of this study was to directly characterize changes in the molecular structure of membrane lipid bilayers resulting from oxidative stress. Membrane samples reconstituted from either synthetic or cardiac phospholipids enriched with polyunsaturated fatty acids were examined at high resolution using small-angle x-ray diffraction methods. In this study, Fe2+/ascorbate-induced lipid peroxidation produced significant and dose-dependent alterations in the basic physical structure of the phospholipid bilayer. Electron density profiles (Angstrom vs. electrons/Angstrom(3)) calculated from the x-ray diffraction data showed a marked reduction in the hydrocarbon core width of dilinoleoyl phosphatidylcholine (DLPC) bilayers from 36 Angstrom to 32 Angstrom, and a decrease in overall membrane width, including surface hydration, from 48.7 Angstrom to 44.6 Angstrom. In addition, a broad decrease in molecular volume was observed +/-3-10 Angstrom from the center of the membrane bilayer, along with interdigitation of the terminal methyl segments. Pronounced changes in the lipid bilayer structure following oxidative stress were also observed in membranes reconstituted from cardiac lipids, including a 4 Angstrom reduction in hydrocarbon core width from 40 Angstrom to 36 Angstrom and interdigitation of the terminal methyl segments. These data provide direct evidence for changes in membrane hydrocarbon core width and molecular volume resulting from phospholipid peroxidation, which may contribute to perturbations in membrane structure/function relationships associated with aging and cardiovascular disease. (C) 1997 Elsevier Science Inc.
引用
收藏
页码:419 / 425
页数:7
相关论文
共 50 条
  • [31] Structure analysis of multiphase systems by anomalous small-angle X-ray scattering
    Tatchev, Dragomir
    PHILOSOPHICAL MAGAZINE, 2008, 88 (12) : 1751 - 1772
  • [33] Speckle structure in small-angle coherent X-ray scattering
    Mainville, J
    Bley, F
    Livet, F
    Geissler, E
    Legrand, JF
    Abernathy, D
    Grubel, G
    Mochrie, SGJ
    Sutton, M
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1997, 30 (02) : 828 - 832
  • [34] Synchrotron X-ray diffraction and small-angle X-ray scattering analyses of the nacre of the Nautilus shell
    Veligzhanin A.A.
    Petrochenkov D.A.
    Khramov E.V.
    Frey D.I.
    Chernyshov A.A.
    Journal of Surface Investigation. X-ray, Synchrotron and Neutron Techniques, 2016, 10 (1) : 198 - 204
  • [35] SMALL-ANGLE X-RAY SCATTERING BY MOSAIC STRUCTURE IN METALS
    BETEKHTIN, VI
    SLUTSKER, AI
    SOVIET PHYSICS SOLID STATE,USSR, 1966, 8 (03): : 614 - +
  • [36] SERIES STRUCTURE AND SMALL-ANGLE X-RAY INTERFERENCE OF POLYETHYLENE
    HENDUS, H
    KOLLOID-ZEITSCHRIFT AND ZEITSCHRIFT FUR POLYMERE, 1973, 251 (10): : 779 - 781
  • [37] Existence of the Schroeder paradox with a Nafion membrane? Small-angle x-ray scattering analysis
    Cornet, N
    Gebel, G
    de Geyer, A
    JOURNAL DE PHYSIQUE IV, 1998, 8 (P5): : 63 - 68
  • [38] Gold Nanoparticle Internal Structure and Symmetry Probed by Unified Small-Angle X-ray Scattering and X-ray Diffraction Coupled with Molecular Dynamics Analysis
    Fleury, Blaise
    Cortes-Huerto, Robinson
    Tache, Olivier
    Testard, Fabienne
    Menguy, Nicolas
    Spalla, Olivier
    NANO LETTERS, 2015, 15 (09) : 6088 - 6094
  • [39] The use of small-angle x-ray diffraction studies for the analysis of structural features in archaeological samples
    Wess, TJ
    Drakopoulos, M
    Snigirev, A
    Wouters, J
    Paris, O
    Fratzl, P
    Collins, M
    Hiller, J
    Nielsen, K
    ARCHAEOMETRY, 2001, 43 : 117 - 129
  • [40] The use of full-profile small-angle reflections in the X-ray diffraction analysis of polycrystals
    Serykh, VP
    INDUSTRIAL LABORATORY, 2000, 66 (04): : 237 - 238