Enhancing dopamine detection using a glassy carbon electrode modified with MWCNTs, quercetin, and Nafion®

被引:141
|
作者
Chen, Po-Yen [1 ]
Vittal, R. [1 ]
Nien, Po-Chin [1 ]
Ho, Kuo-Chuan [1 ,2 ]
机构
[1] Natl Taiwan Univ, Dept Chem Engn, Taipei 10617, Taiwan
[2] Natl Taiwan Univ, Inst Polymer Sci & Engn, Taipei 10617, Taiwan
来源
BIOSENSORS & BIOELECTRONICS | 2009年 / 24卷 / 12期
关键词
Dopamine determination; Ascorbic acid; Multi-wall carbon nanotubes; Quercetin; Nafion (R); Flow injection analysis; SELF-ASSEMBLED MONOLAYERS; NANOTUBE PASTE ELECTRODE; ASCORBIC-ACID; ELECTROCHEMICAL-BEHAVIOR; SELECTIVE DETECTION; VOLTAMMETRIC DETERMINATION; URIC-ACID; FILM; CYCLODEXTRIN; SEROTONIN;
D O I
10.1016/j.bios.2009.05.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Glassy carbon (CC) electrode was modified using multi-wall carbon nanotubes (MWCNTs), quercetin (Q) and Nafion (R) in this sequence. The thus modified electrode was used for the detection of dopamine (DA) in the presence of equimolar ascorbic acid (AA). It is demonstrated in this study that MWCNTs can increase the current response of DA by five-fold and Q can reduce the oxidation overpotential of DA by about 60 mV, compared to these parameters obtained with a bare GC electrode. It is also shown that a layer of Nafion (R) can virtually eliminate the interference of AA for the detection of DA. The GC/MWCNTs/Q/Nafion (R) electrode (hereafter also called composite electrode) shows a current density of about 900 mu A cm(-2) for DA, compared to the value of 80 mu A cm(-2) of the GC electrode and to the value of 390 mu A cm(-2) of the GC/MWCNTs electrode. The 11-fold enhancement in the sensitivity of the GC electrode for DA determination is attributed to the composite modification of the electrode, and is substantiated through various cyclic voltammetric experiments. Cyclic voltammetry (CV) and linear sweep voltammetry were used to characterize the electrodes. Calibration curves of batch and flow systems were obtained by amperometry for the detection of DA. Additionally, the composite modified electrode was tested with a human serum sample for the determination of DA and was found to be promising at our preliminary experiments. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3504 / 3509
页数:6
相关论文
共 50 条
  • [21] Simple strategy for sensitive detection of dopamine using CdTe QDs modified glassy carbon electrode
    Yu, Hong-wei
    Zhang, Ze
    Jiang, Jing-hui
    Pan, Hong-zhi
    Chang, Dong
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (03)
  • [22] Simultaneous Determination of Serotonin and Dopamine at the PEDOP/MWCNTs-Pd Nanoparticle Modified Glassy Carbon Electrode
    Kim, Seul Ki
    Jeon, Seungwon
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2012, 12 (03) : 1903 - 1909
  • [23] Cobalt Ferrite Nanoparticles Modified Glassy Carbon Electrode for the Voltammetric Detection of Dopamine
    Divya, J.
    Divya, V.
    Kumary, V. Anitha
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (08): : 742 - 752
  • [24] Determination of diquat at a Nafion film modified glassy carbon electrode using electrocatalytic voltammetry
    Lu, TW
    Sun, IW
    ELECTROANALYSIS, 2000, 12 (08) : 605 - 609
  • [25] Detection of lead(II) using an glassy carbon electrode modified with Nafion, carbon nanotubes and benzo-18-crown-6
    Sukeri Anandhakumar
    Jayaraman Mathiyarasu
    Microchimica Acta, 2013, 180 : 1065 - 1071
  • [26] Detection of lead(II) using an glassy carbon electrode modified with Nafion, carbon nanotubes and benzo-18-crown-6
    Anandhakumar, Sukeri
    Mathiyarasu, Jayaraman
    MICROCHIMICA ACTA, 2013, 180 (11-12) : 1065 - 1071
  • [27] Hierarchically ordered porous nitrogen doped carbon modified a glassy carbon electrode for voltammetry detection of quercetin
    Wang, Ying
    Qiao, Mengfei
    Mamat, Xamxikamar
    Hu, Xun
    Hu, Guangzhi
    MATERIALS RESEARCH BULLETIN, 2021, 136 (136)
  • [28] Electrochemical Detection of Daphnetin Based on a Glassy Carbon Electrode Modified with Nafion and RGO-TEPA
    Zhou, Ming
    Sheng, Yunjie
    Li, Yangchun
    Wang, Yurong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (04): : 1 - 18
  • [29] Selective Determination of Dopamine, Ascorbic Acid and Uric Acid at SDS-MWCNTs Modified Glassy Carbon Electrode
    Zhang, Jian
    Zhu, Zhixin
    Zhu, Jianling
    Li, Kechang
    Hua, Shucheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (03): : 1264 - 1272
  • [30] Simultaneous determination of dopamine and uric acid on nafion/sodium dodecylbenzenesulfonate composite film modified glassy carbon electrode
    Xiaomei Cao
    Liqiang Luo
    Yaping Ding
    Dawang Yu
    Yibo Gao
    Ye Meng
    Journal of Applied Electrochemistry, 2009, 39 : 1603 - 1608