A systematic evaluation of bioelectrical impedance measurement after hemodialysis session

被引:83
|
作者
Di Iorio, BR
Scalfi, L
Terracciano, V
Bellizzi, V
机构
[1] Solofra Hosp, Nephrol Unit, Solofra, Italy
[2] Solofra Hosp, Dialysis Unit, Solofra, Italy
[3] Polla Hosp, Nephrol Unit, Polla, Italy
[4] Polla Hosp, Dialysis Unit, Polla, Italy
[5] Univ Naples Federico II, Dept Food Sci, Naples, Italy
关键词
bioelectrical impedance analysis; BIA; resistance; reactance; phase angle; body water; hemodialysis;
D O I
10.1111/j.1523-1755.2004.00660.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background. There is still no definitive indication about the ideal point of time to perform bioimpedance analysis (BIA) in hemodialysis patients. Furthermore, the interpretation of data in this regard is difficult because there is still no comprehensive information about the fluctuations in BIA variables occurring in these subjects. The aim of this study was to assess BIA changes occurring in hemodialysis and specifically in the dry-weight state. Methods. We studied 27 anuric patients (20 males and 7 females; age 56.1+/-13.7 years) on chronic hemodialysis. Single-frequency BIA (R, resistance; Xc, reactance; and PhA, phase angle) was performed (1) before and at the end of hemodialysis (dialysis period); (2) 15, 30, 60, 90, and 120 minutes after hemodialysis (postdialysis period); and (3) 24, 48, and 68 hours after hemodialysis (interdialysis period). Results. Body weight decreased by 2.8+/-0.8 kg during hemodialysis, was unchanged during the postdialysis period, and progressively rose during the interdialysis period. At the same time, BIA variables significantly increased during hemodialysis (R, 453+/-74 and 542+/-98 ohm; Xc, 38+/-10 and 53+/-16 ohm; P<0.05), remained stable over the 120-minute period after treatment (R, 538 +/- 94, 539 +/- 95, 538 +/- 94 541 +/- 95, and 544 +/- 95 ohm; and Xc, 53 +/- 15, 53 +/- 15, 51 +/- 16, 52 +/- 16, and 52 +/- 16 ohm; NS), and subsequently declined [R, 471 +/- 79 (P=<0.05 vs. postdialysis), 449+/-71 (P=<0.05 vs. postdialysis), 424 +/- 68 (P=<0.05 vs. postdialysis) ohm; Xc, 42+/-13 (P=<0.05 vs. postdialysis), 37 +/- 10 (P=<0.05 vs. postdialysis), 34+/-13 (P=<0.05 vs. postdialysis) ohm]. The stability of BIA measures during postdialysis was confirmed by the constant relationship found between R/height and Xc/height. Also PhA increased after dialysis (4.8 +/- 1.1 degrees vs. 5.7 +/- 1.3 degrees, P<0.05), was unchanged during the following 120 minutes and decreased in the interdialysis period (5.1+/-1.3 degrees, 4.8+/-1.0 degrees, and 4.5+/-1.1 degrees, P<0.05). At the end of hemodialysis and during the postdialysis period total body water (TBW) estimated from BIA was similar on average to TBW calculated using Watson formulas (37.2 +/- 6.3 L vs. 36.2 +/- 5.7 L, NS). On the contrary, when patients were hyperhydrated BIA significantly overestimated the Watson's values. Conclusion. In hemodialysis patients BIA variables fluctuate to a considerable extent (with the highest values immediately after hemodialysis), but remain constant and highly reproducible over the 120 minutes after the end of hemodialysis, that is, in a dry-weight state. Thus, taking into consideration that the point in time chosen for performing BIA is crucial to properly assess body composition, BIA can be appropriately performed at anytime during the postdialysis period, provided that hydration status does not change due to food or drink consumption.
引用
收藏
页码:2435 / 2440
页数:6
相关论文
共 50 条
  • [1] Bioelectrical impedance analysis before versus after a hemodialysis session in evaluation of nutritional status
    Jankowska, M
    Debska-Slizien, A
    Rutkowski, B
    JOURNAL OF RENAL NUTRITION, 2006, 16 (02) : 137 - 140
  • [2] Bioelectrical impedance and hemodialysis
    Mandolfo, S
    Farina, M
    Imbasciati, E
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1995, 18 (11): : 700 - 704
  • [3] MICROPROCESSOR-BASED SYSTEM FOR MEASUREMENT OF BIOELECTRICAL IMPEDANCE DURING HEMODIALYSIS
    $$$$Hongmin Cul
    Yongjun Lu
    and Jue Yu(Department of Biomedical Engineering
    Chinese Journal of Biomedical Engineering(English Edition), 1995, (04) : 217 - 218
  • [4] Feasibility of Bioelectrical Impedance Spectroscopy Measurement before and after Thoracentesis
    Zink, Matthias Daniel
    Weyer, Soeren
    Pauly, Karolin
    Napp, Andreas
    Dreher, Michael
    Leonhardt, Steffen
    Marx, Nikolaus
    Schauerte, Patrick
    Mischke, Karl
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [5] Bioelectrical impedance analysis and nutritional assessment in hemodialysis
    Oliveira, Claudia M. C.
    Kubrusly, Marcos
    Mota, Rosa S.
    Vasconcelos, Paulo R. L.
    Choukroun, Gabriel
    Oliveira, Valzimeire N.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 : 454 - 454
  • [6] Bioelectrical impedance: The effect of exercise on bioelectrical impedance measurement and calculation of body composition
    Civar, S
    Ozer, K
    Gursel, E
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2006, 77 (01) : A37 - A38
  • [7] Measurement and Evaluation of the Bioelectrical Impedance of the Human Body by Deconvolution of a Square Wave
    Tseng, Yuhwai
    Su, Chauchin
    Liu, Chien-Nan Jimmy
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2010, E93D (06): : 1656 - 1660
  • [8] Evaluation of Intradialytic Hypertension Using Bioelectrical Impedance Combined With Echocardiography in Maintenance Hemodialysis Patients
    Ren, Hongqi
    Gong, Dehua
    He, Xu
    Jia, Fengyu
    He, Qunpeng
    Xu, Bin
    Liu, Zhihong
    THERAPEUTIC APHERESIS AND DIALYSIS, 2018, 22 (01) : 22 - 30
  • [9] Diagnostic Accuracy of Bioelectrical Impedance Analysis Parameters for the Evaluation of Malnutrition in Patients Receiving Hemodialysis
    da Silva, Angela Teodosio
    Hauschild, Daniela Barbieri
    Franco Moreno, Yara Maria
    Dornelles Bastos, Joao Luiz
    Wazlawik, Elisabeth
    NUTRITION IN CLINICAL PRACTICE, 2018, 33 (06) : 831 - 842
  • [10] Evaluation of Electrocardiographic Findings before and after Hemodialysis Session
    Jebali, Hela
    Ghabi, Hiba
    Mami, Ikram
    Ben Fatma, Lilia
    Smaoui, Wided
    Ben Kaab, Badr
    Krid, Madiha
    Ben Hlima, Manel
    Ben Ayed, Tasnim
    Guermazi, Omar
    Mourali, Mohamed Sami
    Beji, Soumaya
    Chermiti, Mohamed
    Zied, Loumi
    Kateb, Hanene
    Hassan, Mohanad
    Ben Hmida, Fethi
    Raies, Lamia
    Zouaghi, Mohamed Karim
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2020, 31 (03) : 639 - 646