Thin magnetic amorphous wires for GMI sensor

被引:0
|
作者
Chiriac, H [1 ]
Tibu, M [1 ]
Dobrea, V [1 ]
Murgulescu, I [1 ]
机构
[1] Natl Inst Res & Dev Tech Phys, Iasi 700050, Romania
来源
关键词
GMI; magnetostriction; permeability; amorphous wires;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a study of the GMI in amorphous conventional wires with nearly zero magnetostriction (Co68.18Fe4.32Si12.5B15) having different diameters obtained by cold drawing processes in multiple steps. The purpose of our work is to find the way in which the sensitivity of GMI effect is affected by the decrease of the wires diameter and also the way in which the stress induced during the cold drawing process influence the configuration of the magnetic domains structure through the modification of the magnetoelastic energy. We have performed a study of the giant magneto-impedance effect (GMI) in nearly zero magnetostrictive conventional amorphous wires with diameters between 150-20 mum. The values of the impedance (Z) and GMI ratio (DeltaZ/Z) were measured in the frequency range 100 kHz - 10 MHz for wires in the as cast state and cold drawn. We obtained a GMI ratio four times higher for cold drawn wires with diameters of 20 - 30 mum subjected to thermomechanical treatments in comparison with the as cast wire of 130 mum diameter. The results are discussed considering the correlation between induced stresses and modifications in circumferential magnetic domains configuration.
引用
收藏
页码:647 / 650
页数:4
相关论文
共 50 条
  • [41] Time-Coded GMI Magnetic Field Sensor
    Cao, Xuan-Huu
    Son, Derac
    JOURNAL OF MAGNETICS, 2009, 14 (03) : 129 - 131
  • [42] Numerical modelling of GMI effect in soft magnetic amorphous ribbons
    Rahman, IZ
    Boboc, A
    Kamruzzaman, M
    Rahman, MA
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2004, 272 : 1862 - 1863
  • [43] Design of GMI micro-magnetic sensor based on Co-based amorphous alloys for space applications
    Jiang Yanwei
    Fang Jiancheng
    Han Peipei
    Song Yujun
    Huang Xuegong
    Zhang Tao
    FIFTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, 2009, 7133
  • [44] Design of a GMI magnetic sensor based on longitudinal excitation
    Yu Geliang
    Bu Xiongzhu
    Xiang Chao
    Xu Hong
    SENSORS AND ACTUATORS A-PHYSICAL, 2010, 161 (1-2) : 72 - 77
  • [45] Effect of Parasitic Capacitance on GMI Magnetic Sensor Performance
    Saez, S.
    Dufay, B.
    Dolabdjian, C.
    Yelon, A.
    Menard, D.
    MATERIALS AND APPLICATIONS FOR SENSORS AND TRANSDUCERS II, 2013, 543 : 261 - +
  • [46] SIGNAL FEATURE EXTRACTION OF GMI SENSOR IN LONGITUDINALLY EXCITATED AMORPHOUS WIRE
    Duan, X. S.
    Xiao, J.
    Qi, X. H.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2016, 118 : 6 - 6
  • [47] RMS-to-DC Converter for GMI Magnetic Sensor
    Zidi, Manel
    Asfour, Aktham
    Yonnet, Jean-Paul
    IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (01)
  • [48] Development of Thin Microwires With Enhanced Magnetic Softness and GMI
    Zhukova, Valentina
    Ipatov, Mihail
    Gonzalez, Julian
    Blanco, Juan M.
    Zhukov, Arcady P.
    IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (11) : 3958 - 3961
  • [49] Ferromagnetic resonance in amorphous magnetic wires
    Baranov, S.A., 1600, (67):
  • [50] Magnetic domain observation in amorphous wires
    Reininger, T.
    Kronmueller, H.
    Gomez-Polo, C.
    Vazquez, M.
    Journal of Applied Physics, 1993, 73 (10 pt 2A)