MEASUREMENT OF Tg IN LYOPHILIZED PROTEIN AND PROTEIN EXCIPIENT MIXTURES BY DYNAMIC MECHANICAL ANALYSIS

被引:10
|
作者
Carpenter, J. [2 ]
Katayama, D. [2 ]
Liu, L. [2 ]
Chonkaew, W. [3 ]
Menard, K. [1 ]
机构
[1] PerkinElmer Life & Analyt Sci Inc, Shelton, CT 06484 USA
[2] Univ Colorado, Hlth Sci Ctr, Sch Pharm, Denver, CO 80262 USA
[3] King Mongkuts Univ Technol, Dept Chem, Bangkok, Thailand
关键词
amorphous; DMA; DSC; excipients; glass transition; lyophilized; proteins; TMA; AMORPHOUS CONTENT; TRANSITION; MOISTURE; STATE; DSC;
D O I
10.1007/s10973-007-8986-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
The glass transition of lyophilized materials is normally measured by conventional or temperature modulated differential scanning calorimetry (TMDSC). However, because of the weakness of these transitions when protein concentrations are high, these techniques are often unable to detect the glass transition (T-g). High ramp rate DSC, where heating rates of 100 K per min and higher are used, has been shown to be able to detect weak transitions in a wide range of materials and has been applied to these materials in previous work. Dynamic mechanical analysis (DMA) is also known to be much more sensitive to the presence of relaxations in materials than other commonly used thermal techniques. The development of a method to handle powders in the DMA makes it now possible to apply this technique to protein and protein-excipient mixtures. HRR DSC, TMA and DMA were used to characterize the glass transition of lyophilized materials and the results correlated. DMA is shown to be a viable alternative to HRR DSC and TMA for lyophilized materials.
引用
收藏
页码:881 / 884
页数:4
相关论文
共 50 条
  • [21] Dynamic Mechanical Properties of Soy Protein Filled Elastomers
    L. Jong
    Journal of Polymers and the Environment, 2005, 13 : 329 - 338
  • [22] Proteomic analysis of dynamic protein complexes
    Egetemaier S.
    Béthune J.
    BIOspektrum, 2019, 25 (1) : 45 - 48
  • [23] Direct mass spectrometry analysis of protein mixtures: Proteomics in pursuit of protein function.
    Yates, JR
    Eng, J
    Wolters, D
    Washburne, M
    Link, A
    Schieltz, D
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U132 - U132
  • [24] SEC-MS analysis of aggregates of in protein mixtures
    Gadgil, H
    Ren, D
    Rainville, P
    Warren, B
    Baynham, M
    Mallet, C
    Mazzeo, J
    Russell, R
    LC GC EUROPE, 2003, : 10 - 11
  • [25] Direct analysis of protein mixtures by tandem mass spectrometry
    Yates, JR
    McCormack, AL
    Schieltz, D
    Carmack, E
    Link, A
    JOURNAL OF PROTEIN CHEMISTRY, 1997, 16 (05): : 495 - 497
  • [26] CHROMATOGRAPHIC ANALYSIS OF PROTEIN MIXTURES ON A CATION EXCHANGE RESIN
    SOBER, HA
    KEGELES, G
    FEDERATION PROCEEDINGS, 1951, 10 (01) : 249 - 250
  • [27] Direct Analysis of Protein Mixtures by Tandem Mass Spectrometry
    Yates, J. R.
    McCormack, A. L.
    Schieltz, D.
    Carmack, E.
    Journal of Protein Chemistry, 16 (05):
  • [28] Direct Analysis of Protein Mixtures by Tandem Mass Spectrometry
    John R. Yates
    Ashley L. McCormack
    David Schieltz
    Edwin Carmack
    Andrew Link
    Journal of Protein Chemistry, 1997, 16 (5): : 495 - 497
  • [29] SEC-MS analysis of aggregates in protein mixtures
    Gadgil, H
    Ren, D
    Rainville, P
    Warren, B
    Baynham, M
    Mallet, C
    Mazzeo, J
    Russell, R
    LC GC NORTH AMERICA, 2003, : 23 - 24
  • [30] MEASUREMENT OF GLASS TRANSITIONS IN SEEDS BY DYNAMIC MECHANICAL ANALYSIS
    WILLIAMS, RJ
    PLANT PHYSIOLOGY, 1993, 102 (01) : 75 - 75