Analysis of frequency distribution of ground fault-current magnitude in transmission networks for electrical safety evaluation

被引:6
|
作者
Coppo, M. [1 ]
Bignucolo, F. [1 ]
Turri, R. [1 ]
Griffiths, H. [2 ]
Harid, N. [2 ]
Haddad, A. [3 ]
机构
[1] Univ Padua, Dept Ind Engn, I-35131 Padua, Italy
[2] KUST, Adv Power & Energy Ctr, ECE Dept, Abu Dhabi, U Arab Emirates
[3] Cardiff Univ, Adv High Voltage Engn Res Ctr, Cardiff, S Glam, Wales
关键词
Ground Potential Rise; Grounding; Power system modeling; Power system faults; TRANSFORMER MODELS; LINES; STATION; TOWERS;
D O I
10.1016/j.epsr.2019.03.024
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Ground Potential Rise (GPR) evaluation under fault conditions is important for the evaluation of electrical safety risk to human beings who are present in and around electric installations. Current national and international standards recommend such evaluation is based on a set of 'worst-case' conditions that include a simplified fault current calculation procedure based on assuming a maximum value. Accordingly, this approach may lead to over-design of grounding systems in certain cases by overestimating individual risk. To address this and move towards a comprehensive probabilistic assessment of risk, a more detailed model of the electric network is required for fault current magnitude evaluation. This paper describes the application of the multi-conductor method to determine fault current distribution on transmission networks. First, a model of a portion of the UK transmission network is built and the fault current and its distribution among the phases, ground wire and ground is evaluated for three example fault positions. It is found that the position of the fault along the line, substation bus section status and proximity to generation affect greatly the current distribution. Then, a transmission model based on the national network is built, and the effects of system loading and generation on fault current magnitude were also considered. A complete frequency distribution of fault current magnitude is obtained and the results demonstrate the value of such description for the probabilistic assessment of human safety in grounding system design.
引用
收藏
页码:100 / 111
页数:12
相关论文
共 50 条
  • [31] ARC-FAULT DETECTION BY FREQUENCY ANALYSIS OF CURRENT IN A CONTINUOUS AIRCRAFT POWER NETWORKS
    Humbert, Jean-Baptiste
    Schweitzer, Patrick
    Weber, Serge
    28TH INTERNATIONAL CONFERENCE ON ELECTRIC CONTACTS (ICEC2016), 2016, : 207 - 211
  • [32] Transient Energy Analysis based Single-Phase-to-Ground Fault Location in Distribution Networks
    Wang, Xuewen
    Zhang, Hengxu
    Shi, Fang
    Xie, Wei
    Ling, Ping
    Liu, Jinsong
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [34] A Single-Phase to Ground Fault Identification Method Based on Extremely Low Frequency Current Detection in Distribution Grids
    Yang, Shiwu
    Jiao, Yang
    Chen, Qing
    Li, Hongbin
    Zhou, Lei
    Zhu, Houda
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (06) : 5214 - 5223
  • [35] Single-phase earth fault current distribution between optical fiber composite overhead ground wire and ordinary ground wire in transmission system
    许高雄
    JournalofChongqingUniversity(EnglishEdition), 2011, 10 (02) : 78 - 83
  • [36] Analysis of voltage transients caused by single-line to ground fault in medium voltage distribution networks
    Kanalik, Martin
    Busa, Jan
    Kyncl, Jan
    PROCEEDINGS OF THE 8TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2015), 2015, : 380 - 383
  • [37] Max mean discrepancy based fault section location method for small-current ground faults in distribution networks
    Tan, Liming
    Yin, Xianggen
    Qiao, Jian
    Wang, Yikai
    Xu, Wen
    Chen, Wei
    ENERGY REPORTS, 2022, 8 : 1437 - 1445
  • [38] Control of three-phase converter for ground fault capacitive current compensation in un-grounded distribution networks
    Smirnov, Pavel
    Kharitonov, Sergey
    Preobrajensky, Evgeniy
    Petzoldt, Juergen
    2016 11TH INTERNATIONAL FORUM ON STRATEGIC TECHNOLOGY (IFOST), PTS 1 AND 2, 2016,
  • [39] Research of fault location in distribution networks based on integration of travelling wave time and frequency analysis
    Liang, Rui
    Jin, Zheng
    Wang, Chonglin
    Liu, Jianhua
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2013, 33 (28): : 130 - 136
  • [40] Study of neutral grounding for 22kV distribution system - (Analyzing the ground fault voltage and current distribution using a power frequency model)
    Oka, K
    Yoshinaga, J
    Koizumi, S
    Uemura, S
    Ariga, Y
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 2143 - 2148