An optical pH sensor with a linear response over a broad range

被引:86
|
作者
Lin, J [1 ]
Liu, D [1 ]
机构
[1] Portland State Univ, Dept Chem, Portland, OR 97207 USA
关键词
pH sensor; optical sensor; pH indicator; sol-gel glass;
D O I
10.1016/S0003-2670(99)00840-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed for achieving a linear response over a broad pH range for optical pH sensors by using mixtures of multiple pH indicators. Requirements on the pH indicators were investigated, including the Delta pK(a) between the indicators, and the colors and concentrations of the indicators. It is demonstrated that a Linear response over a broad pH range can be obtained by using multiple indicators that have Delta pK(a) less than or equal to 1.7. Optimum ratios between the concentrations of the indicators can be calculated by a computer program. A linear response over a range of 4.5 pH units was obtained for a mixture of four indicators in solution. A sol-gel glass pH sensor with a linear response over a range of 3.5 pH units was developed by co-entrapping three indicators in sol-gel glass. In both cases, a standard deviation of pH equal to 0.03 was obtained. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 50 条
  • [21] Research on an Optical Fiber Linear Displacement Sensor Based on Bending Loss for Use over Large Range
    Zheng Yong
    Xiao Wang
    Zhu Zhengwei
    ACTA OPTICA SINICA, 2020, 40 (12)
  • [22] Synthesis and Characterization of a pH Fluorescence Sensor with Tunable Response Range
    Ma Yong-Shan
    Zhang Feng-Xia
    Li Pei-Gang
    Wu Jun-Sen
    Ren Hui-Xue
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (01) : 77 - 82
  • [23] Full-range optical pH sensor based on imaging techniques
    Capel-Cuevas, S.
    Cuellar, M. P.
    de Orbe-Paya, I.
    Pegalajar, M. C.
    Capitan-Vallvey, L. F.
    ANALYTICA CHIMICA ACTA, 2010, 681 (1-2) : 71 - 81
  • [24] Design, calibration and application of broad-range optical nanosensors for determining intracellular pH
    Sondergaard, Rikke V.
    Henriksen, Jonas R.
    Andresen, Thomas L.
    NATURE PROTOCOLS, 2014, 9 (12) : 2841 - 2858
  • [25] Design, calibration and application of broad-range optical nanosensors for determining intracellular pH
    Rikke V Søndergaard
    Jonas R Henriksen
    Thomas L Andresen
    Nature Protocols, 2014, 9 : 2841 - 2858
  • [26] Broad range pH sensor based on sol-gel entrapped indicators on fibre optic
    Dong, Saying
    Luo, Ming
    Peng, Gangding
    Cheng, Wenhua
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (01) : 94 - 98
  • [27] A ratiometric fluorescence sensor with broad dynamic range based on two pH-sensitive fluorophores
    Niu, CG
    Gui, XQ
    Zeng, GM
    Yuan, XZ
    ANALYST, 2005, 130 (11) : 1551 - 1556
  • [28] A Polymer Dots-Based Photoelectrochemical pH Sensor: Simplicity, High Sensitivity, and Broad-Range pH Measurement
    Shi, Xiao-Mei
    Mei, Li-Ping
    Zhang, Nan
    Zhao, Wei-Wei
    Xu, Jing-Juan
    Chen, Hong-Yuan
    ANALYTICAL CHEMISTRY, 2018, 90 (14) : 8300 - 8303
  • [29] On the issues of linearizing a sensor characteristic over a wider response range
    Khan, Sheroz
    Alam, A. H. M. Zahirul
    Ahmmad, Syed Masrur
    Tijani, I. B.
    Hasan, Muhammad Asraful
    Adetunji, Lawal Wahab
    Abdulazeez, Salami Femi
    Zaini, Siti Hana Mohammad
    Othman, Siti Aminah
    Khan, Saman S.
    2008 INTERNATIONAL CONFERENCE ON COMPUTER AND COMMUNICATION ENGINEERING, VOLS 1-3, 2008, : 72 - 76
  • [30] ARRANGEMENT FOR MEASURING LINEAR EXPANSION COEFFICIENT OF WIRE SPECIMENS OVER A BROAD TEMPERATURE RANGE
    VERTOGRADSKII, VA
    INDUSTRIAL LABORATORY, 1969, 35 (04): : 619 - +