Optimization of blood supply chain with shortened shelf lives and ABO compatibility

被引:91
|
作者
Duan, Qinglin [1 ]
Liao, T. Warren [1 ]
机构
[1] Louisiana State Univ, Dept Mech & Ind Engn, Baton Rouge, LA 70803 USA
关键词
Red blood cell; Supply chain; Perishable; Inventory; Hybrid metaheuristic; Simulation optimization; Stochastic demand; Blood ABO compatibility; PLATELET PRODUCTION; INVENTORY MANAGEMENT; ORDERING POLICIES; TRANSFUSION; SYSTEM; MODEL; SIMULATION; ALGORITHM; STORAGE; IMPACT;
D O I
10.1016/j.ijpe.2014.02.012
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In clinical practice, red blood cells (RBCs) have a maximal shelf life (MSL) of 42 days. Recent studies suggest managing RBC inventory with a more restrictive MSL. To this end, a new simulation optimization (SO) framework is proposed for blood supply chain inventory management with ABO blood group compatibility. The inventory objective is to minimize the expected system outdate rate under a predetermined maximally allowable shortage level. The proposed SO framework is incorporated with a new metaheuristic optimization algorithm, TA-TS, to identify near-optimal inventory policies in reasonably acceptable computational time. The new SO framework is shown to offer a better tradeoff between solution accuracy and computational expense. The efficiency of the proposed framework is evaluated in detail for a single-hospital single-blood center supply chain system, in which the MSL of RBC units are shortened to 7, 14 and 21 days. A recently-developed replenishment policy based on old inventory ratio (the OIR policy developed by Duan and Liao (2013b)) is used to control the freshness of the entire inventory. Three different scenarios are investigated: (1) no ABO compatible substitution; (2) ABO compatible substitution at hospital only; (3) ABO compatible substitution at both hospital and blood center. Using the proposed SO framework, we are able to identify a near-optimal solution for each of these scenarios and quantify the potential savings offered by ABO compatible substitution. In the ABO compatible substitution scenarios, there is a clear trend of the increased use of group O blood. As the MSL decreases, group O blood are needed more frequently to substitute for other ABO/Rh(D) compatible blood types. Allowing ABO/Rh(D)-compatible blood substitution helps reduce the system-wide outdate at least by 16% even under the most restrictive MSL For more relax MSL of 14 days and 21 days, the proposed framework is capable of keeping the highest system-wide outdate rate at as little as 2%. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 129
页数:17
相关论文
共 50 条
  • [21] Optimization of LNG Supply Chain
    Bittante, Alice
    Jokinen, Raine
    Pettersson, Frank
    Saxen, Henrik
    12TH INTERNATIONAL SYMPOSIUM ON PROCESS SYSTEMS ENGINEERING (PSE) AND 25TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING (ESCAPE), PT A, 2015, 37 : 779 - 784
  • [22] Optimization of supply chain management
    Yang, Youqi
    Huagong Xiandai/Modern Chemical Industry, 19 (05): : 6 - 9
  • [23] ABO antigen blood-group compatibility in corneal graft rejection
    Soma, T
    Nishida, K
    Sakimoto, S
    Maeda, N
    Watanabe, H
    Tano, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U305 - U305
  • [24] Bullwhip in the Blood Supply Chain
    Rutherford, C.
    Cheng, S.
    Bailie, K.
    TRANSFUSION, 2016, 56 : 214A - 214A
  • [25] Modelling the Blood Supply Chain
    Meneses, Maria
    Santos, Daniel
    Barbosa-Povoa, Ana
    EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2023, 307 (02) : 499 - 518
  • [26] Supply Chain Network Design: Applying Optimization and Analytics to the Global Supply Chain
    Bookbinder, James
    INTERFACES, 2014, 44 (03) : 348 - 349
  • [27] Lead time optimization of MTS-MTO in two-echelon supply chain considering shelf life
    Ma S.-H.
    Wu Z.-R.
    Liu B.-S.
    Kongzhi yu Juece/Control and Decision, 2019, 34 (01): : 129 - 136
  • [28] The Effect of Compatibility of ABO Blood Type Antigens on Graft Survival of Intestinal Transplants
    Cai, J.
    Qing, A.
    Wu, G.
    Everly, M.
    Terasaki, P.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2015, 15
  • [29] ABO antigen blood-group compatibility and allograft rejection in corneal transplantation
    Inoue, K
    Tsuru, T
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1999, 77 (05): : 495 - 499
  • [30] Measurement and optimization of supply chain responsiveness
    Hum, Sin-Hoon
    Parlar, Mahmut
    IIE TRANSACTIONS, 2014, 46 (01) : 1 - 22