Breast cancer screening using digital breast tomosynthesis compared to digital mammography alone for Japanese women

被引:2
|
作者
Ban, Kanako [1 ]
Tsunoda, Hiroko [2 ]
Togashi, Seiko [1 ]
Kawaguchi, Yuko [1 ]
Sato, Takanobu [1 ]
Takahashi, Yoko [1 ]
Nagatsuka, Yoshitaka [1 ]
机构
[1] Tokyo Hlth Serv Assoc, Shinjuku Ku, 1-2 Ichigaya Sadohara Cho, Tokyo 1628402, Japan
[2] St Lukes Int Hosp, Chuo Ku, 9-1 Akashi Cho, Tokyo 1048560, Japan
关键词
Breast cancer screening; Mammography; Digital breast tomosynthesis; 3D mammography; SYNTHESIZED 2-DIMENSIONAL MAMMOGRAPHY; IMPLEMENTATION; COMBINATION; IMAGES;
D O I
10.1007/s12282-020-01180-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background The purpose of this study is to confirm the position of DBT in breast cancer screening in Japan, to assess cancer detection rates, recall rates, positive predictive value (PPV), and to evaluate the type of mammographic findings of cancer with the use of digital mammography alone (2DDM) and combined with digital breast tomosynthesis (DBT). Methods 11,894 examinations of the opportunistic breast cancer screening using only 2DDM and 2DDM plus DBT were performed from May 1, 2017 to March 31, 2019. The 11,894 women [3535 women who received DBT in addition to 2DDM (3D group) and 8359 who received 2DDM only (2D group)] participated in this study. The study was approved by the Institute's Ethics Committee and all participants provided written informed consent. Results The recall rate was 2.6% for the 3D group and 3.6% for the 2D group (p < 0.01). The cancer detection rate was 0.17% in both 3D and 2D groups (p = 0.978). The positive predictive value (PPV) was 6.5% for the 3D group and 4.7% for the 2D group (p = 0.484). The cause of the decrease in recall rate was due to a decrease in the finding of focal asymmetric density (FAD). Conclusion The recall rate was improved by using DBT for breast cancer screening in Japanese women. Cancer detection rates were exactly the same in DBT and 2DDM groups, so only DBT non-inferiority could be verified. We have verified that breast cancer screening combined with DBT is useful even for Japanese women to reduce unnecessary further examination.
引用
收藏
页码:459 / 464
页数:6
相关论文
共 50 条
  • [41] The TOMMY trial: a comparison of TOMosynthesis with digital MammographY in the UK NHS Breast Screening Programme a multicentre retrospective reading study comparing the diagnostic performance of digital breast tomosynthesis and digital mammography with digital mammography alone
    Gilbert, Fiona J.
    Tucker, Lorraine
    Gillan, Maureen G. C.
    Willsher, Paula
    Cooke, Julie
    Duncan, Karen A.
    Michell, Michael J.
    Dobson, Hilary M.
    Lim, Yit Yoong
    Purushothaman, Hema
    Strudley, Celia
    Astley, Susan M.
    Morrish, Oliver
    Young, Kenneth C.
    Duffy, Stephen W.
    HEALTH TECHNOLOGY ASSESSMENT, 2015, 19 (04) : 1 - +
  • [42] COMPARISON BETWEEN DIGITAL MAMMOGRAPHY AND DIGITAL BREAST TOMOSYNTHESIS IN THE DIAGNOSIS OF BREAST CANCER
    Jari, Irina
    Naum, A. G.
    Gheorghe, Liliana
    Negru, D.
    Ursaru, Manuela
    MEDICAL-SURGICAL JOURNAL-REVISTA MEDICO-CHIRURGICALA, 2019, 123 (01): : 102 - 108
  • [43] Screening Mammography and Digital Breast Tomosynthesis: Utilization Updates
    Boroumand, Gilda
    Teberian, Ida
    Parker, Laurence
    Rao, Vijay M.
    Levin, David C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (05) : 1092 - 1096
  • [44] Breast tomosynthesis: A diagnostic addition to screening digital mammography
    El Bakry, Rehab Abdel Rahman
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2018, 49 (02): : 529 - 535
  • [45] Performance of dedicated breast PET in breast cancer screening: comparison with digital mammography plus digital breast tomosynthesis and ultrasound
    Yuge, Shunsuke
    Miyake, Kanae K.
    Ishimori, Takayoshi
    Kataoka, Masako
    Matsumoto, Yoshiaki
    Torii, Masae
    Yakami, Masahiro
    Isoda, Hiroyoshi
    Takakura, Kyoko
    Morita, Satoshi
    Takada, Masahiro
    Toi, Masakazu
    Nakamoto, Yuji
    ANNALS OF NUCLEAR MEDICINE, 2023, 37 (09) : 479 - 493
  • [46] Initial Experience With Digital Breast Tomosynthesis in Screening Mammography
    Philpotts, L.
    Raghu, M.
    Durand, M.
    Hooley, R.
    Vashi, R.
    Horvath, L.
    Geisel, J.
    Butler, R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [47] Performance of dedicated breast PET in breast cancer screening: comparison with digital mammography plus digital breast tomosynthesis and ultrasound
    Shunsuke Yuge
    Kanae K. Miyake
    Takayoshi Ishimori
    Masako Kataoka
    Yoshiaki Matsumoto
    Masae Torii
    Masahiro Yakami
    Hiroyoshi Isoda
    Kyoko Takakura
    Satoshi Morita
    Masahiro Takada
    Masakazu Toi
    Yuji Nakamoto
    Annals of Nuclear Medicine, 2023, 37 : 479 - 493
  • [48] Improvement in diagnostic performance of breast cancer: comparison between conventional digital mammography alone and conventional mammography plus digital breast tomosynthesis
    Ryoko Ohashi
    Michinobu Nagao
    Izumi Nakamura
    Takahiro Okamoto
    Shuji Sakai
    Breast Cancer, 2018, 25 : 590 - 596
  • [49] Impact of digital breast tomosynthesis on screening performance and interval cancer rates compared to digital mammography: A meta-analysis
    Liu, Xuewen
    Yang, Ting
    Yao, Juan
    PLOS ONE, 2025, 20 (01):
  • [50] Performance of Digital Breast Tomosynthesis, Synthetic Mammography, and Digital Mammography in Breast Cancer Screening: A Systematic Review and Meta-Analysis
    Alabousi, Mostafa
    Wadera, Akshay
    Al-Ghita, Mohammed Kashif
    Al-Ghetaa, Rayeh Kashef
    Salameh, Jean-Paul
    Pozdnyakov, Alex
    Zha, Nanxi
    Samoilov, Lucy
    Sharifabadi, Anahita Dehmoobad
    Sadeghirad, Behnam
    Freitas, Vivianne
    McInnes, Matthew D. F.
    Alabousi, Abdullah
    JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2021, 113 (06): : 680 - 690