Exergy analysis and the energy saving mechanism for coal to synthetic/substitute natural gas and power cogeneration system without and with CO2 capture

被引:55
|
作者
Li, Sheng [1 ]
Jin, Hongguang [1 ]
Gao, Lin [1 ]
Zhang, Xiaosong [1 ]
机构
[1] Chinese Acad Sci, Lab Distributed Energy Syst & Renewable Energy, Beijing 100190, Peoples R China
基金
加拿大自然科学与工程研究理事会; 中国国家自然科学基金;
关键词
Exergy analysis; Synthetic/substitute natural gas; IGCC/polygeneration; Carbon capture and storage; Energy saving mechanism; SNG PRODUCTION; PROCESS DESIGN; GASIFICATION; BIOMASS; METHANATION; INTEGRATION; SECTOR;
D O I
10.1016/j.apenergy.2014.03.036
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The energy saving mechanism and the potential of efficiency improvement for coal to synthetic/substitute natural gas and power plant with different schemes and CO2 capture is disclosed through exergy analysis, and the effects of key parameters on exergy losses and system performance are investigated. Scheme A represents the system without CO2 capture but with a full syngas component adjustment and partial recycle of the chemical unconverted gas, Scheme B represents the system without CO2 capture and syngas component adjustment but with partial recycle of the chemical unconverted gas, and Scheme C represents the SNG and power cogeneration with CO2 capture and partial recycle of the chemical unconverted gas but without syngas component adjustment. Results show that the exergy efficiencies of Scheme A, B and C range from 56% to 62%, 57% to 67%, 52% to 62%, respectively. Coal gasification, water-gas-shift process, SNG methanation, and fuel combustion in combined cycle are identified as the main sources of exergy losses. Compared with Scheme A, the exergy efficiency of Scheme B is higher due to the avoidance of exergy losses from syngas adjustment. Scheme C is less energy efficient than Scheme B because of the CO2 capture. Compared with single product systems, the total exergy input of Scheme A, B and C can be reduced by 7.0-11.0%, 14.0-19.0%, 15.0-21.0%, respectively assuming the same product output. The chemical to power output ratio (CPOR) will impact the exergy losses of the whole plant greatly. For all schemes, with the increasing CPOR, the exergy losses for chemical synthesis island will increase whereas the exergy losses for power island will decrease. Especially high CPOR will cause sharp exergy losses of chemical synthesis island. The coupling between exergy losses for chemical synthesis and power islands leads to an optimal CPOR making the total exergy losses of the plant minimal and the system efficiency maximized. The results presented in this paper can help to confirm the potential of system integration and can be a guide for system integration. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:552 / 561
页数:10
相关论文
共 50 条
  • [21] Energy analysis of underground coal gasification with CO2 capture and auxiliary power production
    Self, Stuart J.
    Rosen, Marc A.
    Reddy, Bale V.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2013, 227 (03) : 328 - 337
  • [22] CO2 Reduction to Substitute Natural Gas: Toward a Global Low Carbon Energy System
    Walspurger, Stephane
    Haije, Wim G.
    Louis, Benoit
    ISRAEL JOURNAL OF CHEMISTRY, 2014, 54 (10) : 1432 - 1442
  • [23] Steady state simulation and exergy analysis of supercritical coal-fired power plant with CO2 capture
    Olaleye, Akeem K.
    Wang, Meihong
    Kelsall, Greg
    FUEL, 2015, 151 : 57 - 72
  • [24] Optimizing heat integration in a flexible coal-natural gas power station with CO2 capture
    Kang, Charles A.
    Brandt, Adam R.
    Durlofsky, Louis J.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2014, 31 : 138 - 152
  • [25] COMBUSTION PROPERTIES OF COAL GASIFICATION GAS FOR IGCC POWER GENERATION SYSTEM WITH CO2 CAPTURE
    Kado, Kunihiro
    Nakahara, Takashi
    Takeo, Tomohiro
    Kitagawa, Toshiaki
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 2, 2009, : 7 - 12
  • [26] A novel coal chemical looping gasification scheme for synthetic natural gas with low energy consumption for CO2 capture: Modelling, parameters optimization, and performance analysis
    Zhou, Huairong
    Meng, Wenliang
    Wang, Dongliang
    Li, Guixian
    Li, Hongwei
    Liu, Zhiqiang
    Yang, Sheng
    ENERGY, 2021, 225 (225)
  • [27] Natural gas fired power cycles with integrated CO2 capture
    Bolland, O
    Undrum, H
    Myhre-Nielsen, M
    GREENHOUSE GAS CONTROL TECHNOLOGIES, 2001, : 97 - 102
  • [28] Comparison of costs for natural gas power generation with CO2 capture
    Mathieu, Philippe
    Bolland, Olav
    GHGT-11, 2013, 37 : 2406 - 2419
  • [29] Exergy analysis of a gas-turbine combined-cycle power plant with precombustion CO2 capture
    Ertesvåg, IS
    Kvamsdal, HM
    Bolland, O
    ENERGY, 2005, 30 (01) : 5 - 39
  • [30] Efficiency evaluation procedure of coal-fired power plants with CO2 capture, cogeneration and hybridization
    Hagi, Hayato
    Neveux, Thibaut
    Le Moullec, Yann
    ENERGY, 2015, 91 : 306 - 323