An ionic liquid-based ultrasound assisted dispersive liquid-liquid microextraction procedure followed by HPLC for the determination of low concentration of phytocides in soil

被引:32
|
作者
Dong, Sheying [1 ,2 ]
Hu, Qing [1 ]
Yang, Zhen [1 ]
Liu, Rong [1 ]
Huang, Guiqi [1 ]
Huang, Tinglin [2 ]
机构
[1] Xian Univ Architecture & Technol, Coll Sci, Xian 710055, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian 710055, Peoples R China
基金
中国国家自然科学基金;
关键词
Ionic liquid; Dispersive liquid-liquid microextraction; High-performance liquid chromatography; Phytocides; Soil samples; ATOMIC-ABSORPTION-SPECTROMETRY; PHASE MICROEXTRACTION; MASS-SPECTROMETRY; CHROMATOGRAPHY; WATER; HERBICIDES; PRECONCENTRATION; PERFORMANCE; PESTICIDES; EXTRACTION;
D O I
10.1016/j.microc.2013.03.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and efficient method known as the ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction (IL-USA-DLLME) combined with high-performance liquid chromatography (HPLC) was successfully developed for the extraction and determination of three phytocides (imazethapyr, bensulfuron, and uniconazole) in soil samples. Several experimental parameters that influence extraction and determination, such as the type and volume of extraction solvent, the volume of disperser solvent, pH of solution, salt effect, ultrasound time, and the chromatographic conditions were investigated. Under optimal conditions, a linear relationship was observed in the range of 0.1000-200.0 mu g/mL with the correlation coefficients (r(2)) ranging from 0.9965 to 0.9990, and the limit of detections (LODs) ranged from 0.0500 to 03100 mu g/mL for the three analytes. The relative standard deviations (RSD) at two spiking with different concentration levels of 6.600 mu g/mL and 16.00 mu g/mL varied from 0.9% to 2.4% (n = 6), and recoveries were between 87.10 and 95.01%. On the basis of this, phytocides in two actual soil samples from a wheat field and a vegetable farm were analyzed. This work demonstrated that IL-USA-DLLME method with 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide ([BMIM]TFSI) could be used to detect the trace amounts of phytocides in soils. This method has the advantage of high extraction efficiency, good sensitivity, simplicity and environmental friendliness. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:221 / 226
页数:6
相关论文
共 50 条
  • [31] Selective determination of metal chlorocomplexes in saline waters by magnetic ionic liquid-based dispersive liquid-liquid microextraction
    Herce-Sesa, Belen
    Lopez-Lopez, Jose A.
    Moreno, Carlos
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (07) : 1369 - 1379
  • [32] Optimization of ionic liquid-based microwave-assisted dispersive liquid-liquid microextraction for the determination of plasticizers in water by response surface methodology
    Wang, Ruoyu
    Su, Ping
    Yang, Yi
    ANALYTICAL METHODS, 2013, 5 (04) : 1033 - 1039
  • [33] Ultrasonication ionic liquid-based dispersive liquid-liquid microextraction of palladium in water samples and determination of microsampler system-assisted FAAS
    Citak, Demirhan
    Tuzen, Mustafa
    DESALINATION AND WATER TREATMENT, 2015, 53 (10) : 2686 - 2691
  • [34] Ionic liquid-based dispersive liquid–liquid microextraction for the determination of formaldehyde in wastewaters and detergents
    Majid Arvand
    Elahe Bozorgzadeh
    Shahab Shariati
    Mohammad Ali Zanjanchi
    Environmental Monitoring and Assessment, 2012, 184 : 7597 - 7605
  • [35] Ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction combined with electrothermal atomic absorption spectrometry for a sensitive determination of cadmium in water samples
    Li, Shengqing
    Cai, Shun
    Hu, Wei
    Chen, Hao
    Liu, Hanlan
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (07) : 666 - 671
  • [36] Ionic liquid/ionic liquid dispersive liquid-liquid microextraction
    Zhao, Ru-Song
    Wang, Xia
    Li, Fu-Wei
    Wang, Shan-Shan
    Zhang, Li-Li
    Cheng, Chuan-Ge
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (07) : 830 - 836
  • [37] Ionic liquid-based dispersive liquid–liquid microextraction followed by magnetic solid-phase extraction for determination of quinolones
    Jiawei Hong
    Xiaomei Liu
    Xiuying Yang
    Yousheng Wang
    Longshan Zhao
    Microchimica Acta, 2022, 189
  • [38] Ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction coupled with high performance liquid chromatography for simultaneous determination of five phenolic pollutants in edible oil
    Zhang, Di
    Wen, Xiaoyun
    Chen, Xinyue
    Tan, Yufan
    Xie, Meiyi
    Wang, Mei
    MICROCHEMICAL JOURNAL, 2025, 211
  • [39] Low Density Ionic Liquid-Based Ultrasound-Assisted Dispersive Liquid–Liquid Microextraction for the Preconcentration of Trace Aromatic Amines in Waters
    Justyna Werner
    Journal of Analytical Chemistry, 2021, 76 : 1182 - 1188
  • [40] One-step in-syringe ionic liquid-based dispersive liquid-liquid microextraction
    Cruz-Vera, Marta
    Lucena, Rafael
    Cardenas, Soledad
    Valcarcel, Miguel
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (37) : 6459 - 6465