Pulsed tissue Doppler imaging for the detection of myocardial ischaemia, a comparison with myocardial perfusion SPECT

被引:5
|
作者
Blomstrand, P [1 ]
Maret, E
Ohlsson, J
Scheike, M
Karlsson, JE
Säfström, K
Swahn, E
Engvall, J
机构
[1] Cty Hosp Ryhov, Dept Clin Physiol, S-55185 Jonkoping, Sweden
[2] Univ Hosp, Linkoping Heart Ctr, Linkoping, Sweden
关键词
dobutamine; echocardiography; myocardial perfusion SPECT; tissue Doppler;
D O I
10.1111/j.1475-097X.2004.00564.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
In order to compare the diagnostic ability of pulsed tissue Doppler and myocardial perfusion Single Photon Emission Computed Tomography (SPECT) in patients with a history of unstable coronary artery disease, CAD, 26 patients, 22 men and four women, age 47-76 years, were investigated in a prospective study, 5-10 day after an episode of unstable angina. Tissue Doppler and two-dimensional echocardiography were performed during dobutamine stress testing and myocardial scintigraphy after bicycle exercise and at rest. Patients with a normal SPECT had higher peak systolic velocity during dobutamine infusion, 18.9 +/- 4.1 cm s(-1), than patients with ischaemia, 12.2 +/- 3.8 cm s(-1) (P<0.001) or scar, 8.8 +/- 3.0 cm s(-1) (P<0.01). In a territorial analysis the difference in peak systolic velocity between areas with a normal and abnormal SPECT was less apparent. Failure to achieve greater than or equal to13 cm s(-1) in mean-peak systolic velocity was the most accurate criterion for detection of significant CAD on SPECT. We conclude that pulsed tissue Doppler can be used for objective quantification of left ventricular wall motion during dobutamine stress testing and for identification of patients with CAD on SPECT but not for identification of regional ischaemia.
引用
收藏
页码:289 / 295
页数:7
相关论文
共 50 条
  • [31] Quantification of ischaemia on myocardial perfusion imaging reply
    French, Matthew
    Yao, Yao
    Dharmalingam, Ashok
    Collins, Nicholas
    INTERNAL MEDICINE JOURNAL, 2022, 52 (07) : 1290 - 1290
  • [32] Optimisation of IQ. SPECT in Myocardial Perfusion Imaging - Comparison with Conventional SPECT and Echocardiography Imaging
    Joel, E.
    Bouchareb, Y.
    Haroon, A.
    Luqman, M.
    Newell, M.
    Jan, H.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [33] Comparison of the Extent and Severity of Myocardial Perfusion Defects Measured by CT Coronary Angiography and SPECT Myocardial Perfusion Imaging
    Tamarappoo, Balaji K.
    Dey, Damini
    Nakazato, Ryo
    Shmilovich, Haim
    Smith, Thomas
    Cheng, Victor Y.
    Thomson, Louise E. J.
    Hayes, Sean W.
    Friedman, John D.
    Germano, Guido
    Slomka, Piotr J.
    Berman, Daniel S.
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (10) : 1010 - 1019
  • [34] Myocardial tissue motion influence on laser Doppler perfusion monitoring using tissue Doppler imaging
    M. G. D. Karlsson
    L. Hübbert
    U. Lönn
    B. Janerot-Sjöberg
    H. Casimir-Ahn
    K. Wårdell
    Medical and Biological Engineering and Computing, 2004, 42 : 770 - 776
  • [35] Myocardial tissue motion influence on laser Doppler perfusion monitoring using tissue Doppler imaging
    Karlsson, MGD
    Hübbert, L
    Lönn, U
    Janerot-Sjöberg, B
    Casimir-Ahn, H
    Wårdell, K
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (06) : 770 - 776
  • [36] Phase analysis of gated myocardial perfusion SPECT compared to tissue Doppler imaging for the assessment of left ventricular dyssynchrony
    Henneman, Maureen M.
    Chen, Ji
    Ypenburg, Claudia
    Dibbets, Petra
    Bleeker, Gabe B.
    Boersma, Eric
    Stokkel, Marcel P.
    van der Wall, Ernst E.
    Garcia, Ernest V.
    Bax, Jeroen J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 132A - 132A
  • [37] DETECTION OF MYOCARDIAL ISCHEMIA SECONDARY TO MYOCARDIAL BRIDGING: A COMPARATIVE STUDY OF EXERCISE SPECT AND CT MYOCARDIAL PERFUSION IMAGING
    Valdiviezo, Carolina
    Bengel, Frank M.
    Arbab-Zadeh, Armin
    Vavere, Andrea L.
    Becker, Lewis
    Lardo, Albert C.
    Lima, Joao A. C.
    George, Richard T.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E797 - E797
  • [38] Pulsed tissue Doppler imaging to assess myocardial viability by quantification of regional myocardial functional reserve
    Yuan, DH
    Kühl, H
    Nowak, B
    Kleinhans, E
    Kaiser, HJ
    Franke, A
    Büll, U
    Hanrath, P
    Hoffmann, R
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (08): : 657 - 664
  • [39] Comparison of accuracy of quantitative techniques for myocardial SPECT perfusion imaging.
    Hansen, CL
    Kramer, M
    Rastogi, A
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 102P - 103P
  • [40] Adenosine stress myocardial contrast perfusion imaging: Comparison with radionuclide SPECT
    Porter, TR
    Mahrous, H
    Xie, F
    Hankins, J
    O'Leary, E
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 151A - 151A